腰椎皮质轨迹探索:干骸骨形态计量学研究:泰国的一项回顾性研究。

IF 2.3 Q2 ORTHOPEDICS Asian Spine Journal Pub Date : 2024-10-01 Epub Date: 2024-10-22 DOI:10.31616/asj.2024.0223
Parika Hanarwut, Sitthichai Iamsaard, Permsak Paholpak, Taweechok Wisanuyotin, Yuichi Kasai, Laphatrada Yurasakpong, Athikhun Suwannakhan, Arada Chaiyamoon
{"title":"腰椎皮质轨迹探索:干骸骨形态计量学研究:泰国的一项回顾性研究。","authors":"Parika Hanarwut, Sitthichai Iamsaard, Permsak Paholpak, Taweechok Wisanuyotin, Yuichi Kasai, Laphatrada Yurasakpong, Athikhun Suwannakhan, Arada Chaiyamoon","doi":"10.31616/asj.2024.0223","DOIUrl":null,"url":null,"abstract":"<p><strong>Study design: </strong>Retrospective cohort study.</p><p><strong>Purpose: </strong>This study aimed to explore the morphometry of the Thai lumbar vertebrae.</p><p><strong>Overview of literature: </strong>The cortical bone trajectory (CBT) is a novel approach for vertebral screw fixation aimed at addressing spinal instability associated with spinal disorders. The morphometry of the lumbar vertebrae is crucial in tailoring screw design for each CBT application, given the significant variations in optimal screw sizes, lengths, and angles among populations.</p><p><strong>Methods: </strong>A total of 300 dried lumbar columns were used to measure the pedicle height (PH) and width (PW), length for cortical bone trajectory (LCT), cephalad screw angle (CSA), axial cortical bone trajectory angle (ACA), and possible cortical zones for the CBT.</p><p><strong>Results: </strong>The following average values were calculated: PH in L1, 15.09±1.44 mm; PW in L5, 16.96±2.42 mm; LCT in L3, 35.75±2.61 mm; CSA in L1, 20.85°±2.30°; and ACA in L5, 21.83°±2.49°. Women generally had shorter PH and PW than men, with significant differences across lumbar levels. The LCT was significantly shorter in women and was notably different between the left and right sides. The CSA and ACA varied significantly between sexes and sides, with specific lumbar levels showing wider angles in one sex over the other. The most common cortical zones for screw tips were Z3 and Z10, with high incidences across all lumbar levels.</p><p><strong>Conclusions: </strong>This study presents detailed lumbar vertebral morphometry data specific to the Thai population. The results are essential for CBT application in screw fixation procedures. This information will contribute to the production of optimally designed screws for Thai patients in the future.</p>","PeriodicalId":8555,"journal":{"name":"Asian Spine Journal","volume":" ","pages":"654-662"},"PeriodicalIF":2.3000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11538813/pdf/","citationCount":"0","resultStr":"{\"title\":\"Exploring cortical trajectory of the lumbar vertebrae: a morphometric study in dry skeletons: a retrospective study in Thailand.\",\"authors\":\"Parika Hanarwut, Sitthichai Iamsaard, Permsak Paholpak, Taweechok Wisanuyotin, Yuichi Kasai, Laphatrada Yurasakpong, Athikhun Suwannakhan, Arada Chaiyamoon\",\"doi\":\"10.31616/asj.2024.0223\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Study design: </strong>Retrospective cohort study.</p><p><strong>Purpose: </strong>This study aimed to explore the morphometry of the Thai lumbar vertebrae.</p><p><strong>Overview of literature: </strong>The cortical bone trajectory (CBT) is a novel approach for vertebral screw fixation aimed at addressing spinal instability associated with spinal disorders. The morphometry of the lumbar vertebrae is crucial in tailoring screw design for each CBT application, given the significant variations in optimal screw sizes, lengths, and angles among populations.</p><p><strong>Methods: </strong>A total of 300 dried lumbar columns were used to measure the pedicle height (PH) and width (PW), length for cortical bone trajectory (LCT), cephalad screw angle (CSA), axial cortical bone trajectory angle (ACA), and possible cortical zones for the CBT.</p><p><strong>Results: </strong>The following average values were calculated: PH in L1, 15.09±1.44 mm; PW in L5, 16.96±2.42 mm; LCT in L3, 35.75±2.61 mm; CSA in L1, 20.85°±2.30°; and ACA in L5, 21.83°±2.49°. Women generally had shorter PH and PW than men, with significant differences across lumbar levels. The LCT was significantly shorter in women and was notably different between the left and right sides. The CSA and ACA varied significantly between sexes and sides, with specific lumbar levels showing wider angles in one sex over the other. The most common cortical zones for screw tips were Z3 and Z10, with high incidences across all lumbar levels.</p><p><strong>Conclusions: </strong>This study presents detailed lumbar vertebral morphometry data specific to the Thai population. The results are essential for CBT application in screw fixation procedures. This information will contribute to the production of optimally designed screws for Thai patients in the future.</p>\",\"PeriodicalId\":8555,\"journal\":{\"name\":\"Asian Spine Journal\",\"volume\":\" \",\"pages\":\"654-662\"},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2024-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11538813/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Asian Spine Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.31616/asj.2024.0223\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/10/22 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Asian Spine Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31616/asj.2024.0223","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/10/22 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

摘要

研究设计目的:本研究旨在探讨泰国腰椎的形态学:皮质骨轨迹(CBT)是一种新型的椎体螺钉固定方法,旨在解决与脊柱疾病相关的脊柱不稳定性问题。由于不同人群的最佳螺钉尺寸、长度和角度存在显著差异,因此腰椎的形态测量对于为每种 CBT 应用量身定制螺钉设计至关重要:共使用 300 根干燥的腰椎柱测量椎弓根高度(PH)和宽度(PW)、皮质骨轨迹长度(LCT)、头侧螺钉角度(CSA)、轴向皮质骨轨迹角度(ACA)以及 CBT 可能的皮质区:计算得出的平均值如下L1的PH值为15.09±1.44 mm;L5的PW值为16.96±2.42 mm;L3的LCT值为35.75±2.61 mm;L1的CSA值为20.85°±2.30°;L5的ACA值为21.83°±2.49°。女性的PH值和PW值普遍短于男性,不同腰椎级别之间存在显著差异。女性的 LCT 明显较短,且左右两侧差异明显。CSA和ACA在性别和两侧之间存在显著差异,特定腰椎水平的角度在一种性别比另一种性别更宽。螺钉尖端最常见的皮质区是 Z3 和 Z10,在所有腰椎级别中的发生率都很高:本研究提供了泰国人特有的详细腰椎形态测量数据。这些结果对于在螺钉固定手术中应用 CBT 至关重要。这些信息将有助于将来为泰国患者设计出最佳的螺钉。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Exploring cortical trajectory of the lumbar vertebrae: a morphometric study in dry skeletons: a retrospective study in Thailand.

Study design: Retrospective cohort study.

Purpose: This study aimed to explore the morphometry of the Thai lumbar vertebrae.

Overview of literature: The cortical bone trajectory (CBT) is a novel approach for vertebral screw fixation aimed at addressing spinal instability associated with spinal disorders. The morphometry of the lumbar vertebrae is crucial in tailoring screw design for each CBT application, given the significant variations in optimal screw sizes, lengths, and angles among populations.

Methods: A total of 300 dried lumbar columns were used to measure the pedicle height (PH) and width (PW), length for cortical bone trajectory (LCT), cephalad screw angle (CSA), axial cortical bone trajectory angle (ACA), and possible cortical zones for the CBT.

Results: The following average values were calculated: PH in L1, 15.09±1.44 mm; PW in L5, 16.96±2.42 mm; LCT in L3, 35.75±2.61 mm; CSA in L1, 20.85°±2.30°; and ACA in L5, 21.83°±2.49°. Women generally had shorter PH and PW than men, with significant differences across lumbar levels. The LCT was significantly shorter in women and was notably different between the left and right sides. The CSA and ACA varied significantly between sexes and sides, with specific lumbar levels showing wider angles in one sex over the other. The most common cortical zones for screw tips were Z3 and Z10, with high incidences across all lumbar levels.

Conclusions: This study presents detailed lumbar vertebral morphometry data specific to the Thai population. The results are essential for CBT application in screw fixation procedures. This information will contribute to the production of optimally designed screws for Thai patients in the future.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Asian Spine Journal
Asian Spine Journal ORTHOPEDICS-
CiteScore
5.10
自引率
4.30%
发文量
108
审稿时长
24 weeks
期刊最新文献
Normative values of non-radiological surface measurement of the lumbar lordosis curvature in the standing position and its association with age, sex, and body mass index: a cross-sectional study of 2,500 healthy individuals from Iran. A magnetic resonance imaging-based morphometric analysis of bilateral L1-L5 oblique lumbar interbody fusion corridor: feasibility of safe surgical approach and influencing factors. A novel pedicle screw design to maximize screw-bone interface strength using finite element analysis and design of experiment techniques. Factors related to surgical site infection in spinal instrumentation surgery: a retrospective study in Japan. Perioperative complications in patients aged ≥85 years undergoing spinal surgery: a retrospective comparative study of pre-old and old patients in Japan.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1