突然增加潮气末二氧化碳分压后的脑电图抑制:一个病例系列。

IF 4.6 Q2 MATERIALS SCIENCE, BIOMATERIALS ACS Applied Bio Materials Pub Date : 2024-10-15 DOI:10.1186/s12871-024-02764-7
Shikuo Li, Yuyi Zhao, Qifeng Wang, Xuehan Li, Chao Chen, Yunxia Zuo
{"title":"突然增加潮气末二氧化碳分压后的脑电图抑制:一个病例系列。","authors":"Shikuo Li, Yuyi Zhao, Qifeng Wang, Xuehan Li, Chao Chen, Yunxia Zuo","doi":"10.1186/s12871-024-02764-7","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Prolonged electroencephalographic depression during surgery is associated with poor outcomes for patients. However, the published literature on electroencephalographic depression caused by a sudden increase in the partial pressure of end-tidal carbon dioxide (P<sub>ET</sub>CO<sub>2</sub>) is lacking.</p><p><strong>Case presentation: </strong>We report four patients who were scheduled for laparoscopic liver surgery under general anesthesia. During the process of EEG monitoring with Sedline, four patients experienced electroencephalographic depression closely after a sudden increase in P<sub>ET</sub>CO<sub>2</sub>. The four patients showed that electroencephalographic depression mainly manifested as a slow in EEG frequency, a reduction in the amplitude and power of EEG, and a decrease in spectral edge frequency. Patient state index was elevated in three cases.</p><p><strong>Conclusions: </strong>To summarize, our patients showed EEG depression when P<sub>ET</sub>CO<sub>2</sub> suddenly increased, which suggests that clinical doctors should be alert to electroencephalographic depression when the P<sub>ET</sub>CO<sub>2</sub> abruptly increases. EEG monitoring devices should be applied in patients with possible hypercapnia. Anesthesiologists must comprehensively interpret the raw EEG, spectral edge frequency, and density spectral array data, in addition to patient sedation index values.</p>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2024-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11476937/pdf/","citationCount":"0","resultStr":"{\"title\":\"Electroencephalographic depression after abruptly increasing partial pressure of end-tidal carbon dioxide: a case series.\",\"authors\":\"Shikuo Li, Yuyi Zhao, Qifeng Wang, Xuehan Li, Chao Chen, Yunxia Zuo\",\"doi\":\"10.1186/s12871-024-02764-7\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Prolonged electroencephalographic depression during surgery is associated with poor outcomes for patients. However, the published literature on electroencephalographic depression caused by a sudden increase in the partial pressure of end-tidal carbon dioxide (P<sub>ET</sub>CO<sub>2</sub>) is lacking.</p><p><strong>Case presentation: </strong>We report four patients who were scheduled for laparoscopic liver surgery under general anesthesia. During the process of EEG monitoring with Sedline, four patients experienced electroencephalographic depression closely after a sudden increase in P<sub>ET</sub>CO<sub>2</sub>. The four patients showed that electroencephalographic depression mainly manifested as a slow in EEG frequency, a reduction in the amplitude and power of EEG, and a decrease in spectral edge frequency. Patient state index was elevated in three cases.</p><p><strong>Conclusions: </strong>To summarize, our patients showed EEG depression when P<sub>ET</sub>CO<sub>2</sub> suddenly increased, which suggests that clinical doctors should be alert to electroencephalographic depression when the P<sub>ET</sub>CO<sub>2</sub> abruptly increases. EEG monitoring devices should be applied in patients with possible hypercapnia. Anesthesiologists must comprehensively interpret the raw EEG, spectral edge frequency, and density spectral array data, in addition to patient sedation index values.</p>\",\"PeriodicalId\":2,\"journal\":{\"name\":\"ACS Applied Bio Materials\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.6000,\"publicationDate\":\"2024-10-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11476937/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Bio Materials\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1186/s12871-024-02764-7\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MATERIALS SCIENCE, BIOMATERIALS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12871-024-02764-7","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0

摘要

背景:手术期间长时间的脑电抑制与患者的不良预后有关。然而,关于潮气末二氧化碳分压(PETCO2)突然升高导致的脑电抑制的文献尚缺:我们报告了四例计划在全身麻醉下进行腹腔镜肝脏手术的患者。在使用 Sedline 进行脑电图监测的过程中,四名患者在 PETCO2 突然升高后紧接着出现了脑电抑制。四名患者的脑电抑制主要表现为脑电图频率减慢、脑电图振幅和功率减小、频谱边缘频率降低。3例患者的状态指数升高:综上所述,我们的患者在 PETCO2 突然升高时出现脑电图抑制,这提示临床医生应警惕 PETCO2 突然升高时出现的脑电图抑制。对于可能出现高碳酸血症的患者,应使用脑电图监测设备。麻醉医生必须全面解读原始脑电图、频谱边缘频率和密度谱阵列数据,以及患者镇静指数值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Electroencephalographic depression after abruptly increasing partial pressure of end-tidal carbon dioxide: a case series.

Background: Prolonged electroencephalographic depression during surgery is associated with poor outcomes for patients. However, the published literature on electroencephalographic depression caused by a sudden increase in the partial pressure of end-tidal carbon dioxide (PETCO2) is lacking.

Case presentation: We report four patients who were scheduled for laparoscopic liver surgery under general anesthesia. During the process of EEG monitoring with Sedline, four patients experienced electroencephalographic depression closely after a sudden increase in PETCO2. The four patients showed that electroencephalographic depression mainly manifested as a slow in EEG frequency, a reduction in the amplitude and power of EEG, and a decrease in spectral edge frequency. Patient state index was elevated in three cases.

Conclusions: To summarize, our patients showed EEG depression when PETCO2 suddenly increased, which suggests that clinical doctors should be alert to electroencephalographic depression when the PETCO2 abruptly increases. EEG monitoring devices should be applied in patients with possible hypercapnia. Anesthesiologists must comprehensively interpret the raw EEG, spectral edge frequency, and density spectral array data, in addition to patient sedation index values.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
ACS Applied Bio Materials
ACS Applied Bio Materials Chemistry-Chemistry (all)
CiteScore
9.40
自引率
2.10%
发文量
464
期刊最新文献
A Systematic Review of Sleep Disturbance in Idiopathic Intracranial Hypertension. Advancing Patient Education in Idiopathic Intracranial Hypertension: The Promise of Large Language Models. Anti-Myelin-Associated Glycoprotein Neuropathy: Recent Developments. Approach to Managing the Initial Presentation of Multiple Sclerosis: A Worldwide Practice Survey. Association Between LACE+ Index Risk Category and 90-Day Mortality After Stroke.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1