心内起搏装置诱发严重三尖瓣反流的表型。

IF 2.6 4区 医学 Q1 MEDICINE, GENERAL & INTERNAL Medicina Clinica Pub Date : 2024-10-15 DOI:10.1016/j.medcli.2024.08.002
Jose Alberto de Agustín, Orlando Figueroa, Carmen Olmos Blanco, Eduardo Pozo Osinalde, Patricia Mahia Casado, María Luaces, María Rivadeneira, Pedro Marcos-Alberca, Jose Juan Gómez de Diego, Luis Collado Yurrita, Antonio Fernández-Ortiz, Julián Villacastín
{"title":"心内起搏装置诱发严重三尖瓣反流的表型。","authors":"Jose Alberto de Agustín, Orlando Figueroa, Carmen Olmos Blanco, Eduardo Pozo Osinalde, Patricia Mahia Casado, María Luaces, María Rivadeneira, Pedro Marcos-Alberca, Jose Juan Gómez de Diego, Luis Collado Yurrita, Antonio Fernández-Ortiz, Julián Villacastín","doi":"10.1016/j.medcli.2024.08.002","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction and aims: </strong>Tricuspid regurgitation (TR) induced by the implantation of cardiac implantable electronic devices (CIED) is an increasingly common cause of severe TR. Our aim was to describe the echocardiographic phenotypic characteristics of CIED-induced severe TR.</p><p><strong>Methods: </strong>Retrospective cohort study that included patients with severe TR related to CIED diagnosed in the cardiac imaging unit of a Spanish tertiary hospital.</p><p><strong>Results: </strong>37 patients with severe TR induced by lead/electrode interference formed our study group. TR was predominantly severe (68%), followed by massive (21%) and torrential (11%). The leaflet most affected by the interference was the septal. 58% of the sample presented severe dilatation of the right atrium (RA) (mean RA area 28cm<sup>2</sup>). Mean tricuspid annulus measurement was 42mm. The usual parameters for quantifying RV systolic function were on average within the normal range (TAPSE mean 19mm, S' wave 10mm, FAC 41%), while global RV strain (RVGLS -15%) and free wall strain (RVFWLS -19%) were found reduced. An incipient degree of ventricular/pulmonary arterial uncoupling was evident (mean TAPSE/PSAP 0.34, SGLVD/PSAP 0.27%/mmHg).</p><p><strong>Conclusions: </strong>Our patients with CIED-induced severe TR are characterized by a heterogeneous phenotype with a high prevalence of severe RA and tricuspid annulus dilatation. RVGLS, RVFWLS, and arterial ventricular coupling were the most sensitive parameters for early assessment of RV systolic dysfunction.</p>","PeriodicalId":18578,"journal":{"name":"Medicina Clinica","volume":" ","pages":""},"PeriodicalIF":2.6000,"publicationDate":"2024-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Phenotype of severe tricuspid regurgitation induced by intracardiac pacing devices.\",\"authors\":\"Jose Alberto de Agustín, Orlando Figueroa, Carmen Olmos Blanco, Eduardo Pozo Osinalde, Patricia Mahia Casado, María Luaces, María Rivadeneira, Pedro Marcos-Alberca, Jose Juan Gómez de Diego, Luis Collado Yurrita, Antonio Fernández-Ortiz, Julián Villacastín\",\"doi\":\"10.1016/j.medcli.2024.08.002\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction and aims: </strong>Tricuspid regurgitation (TR) induced by the implantation of cardiac implantable electronic devices (CIED) is an increasingly common cause of severe TR. Our aim was to describe the echocardiographic phenotypic characteristics of CIED-induced severe TR.</p><p><strong>Methods: </strong>Retrospective cohort study that included patients with severe TR related to CIED diagnosed in the cardiac imaging unit of a Spanish tertiary hospital.</p><p><strong>Results: </strong>37 patients with severe TR induced by lead/electrode interference formed our study group. TR was predominantly severe (68%), followed by massive (21%) and torrential (11%). The leaflet most affected by the interference was the septal. 58% of the sample presented severe dilatation of the right atrium (RA) (mean RA area 28cm<sup>2</sup>). Mean tricuspid annulus measurement was 42mm. The usual parameters for quantifying RV systolic function were on average within the normal range (TAPSE mean 19mm, S' wave 10mm, FAC 41%), while global RV strain (RVGLS -15%) and free wall strain (RVFWLS -19%) were found reduced. An incipient degree of ventricular/pulmonary arterial uncoupling was evident (mean TAPSE/PSAP 0.34, SGLVD/PSAP 0.27%/mmHg).</p><p><strong>Conclusions: </strong>Our patients with CIED-induced severe TR are characterized by a heterogeneous phenotype with a high prevalence of severe RA and tricuspid annulus dilatation. RVGLS, RVFWLS, and arterial ventricular coupling were the most sensitive parameters for early assessment of RV systolic dysfunction.</p>\",\"PeriodicalId\":18578,\"journal\":{\"name\":\"Medicina Clinica\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2024-10-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Medicina Clinica\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1016/j.medcli.2024.08.002\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"MEDICINE, GENERAL & INTERNAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medicina Clinica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.medcli.2024.08.002","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0

摘要

导言和目的:植入心脏植入式电子装置(CIED)引起的三尖瓣反流(TR)是导致严重TR的一个日益常见的原因。我们的目的是描述 CIED 引起的严重 TR 的超声心动图表型特征:方法:回顾性队列研究,纳入西班牙一家三甲医院心脏影像科诊断的与 CIED 相关的严重 TR 患者:37名因导联/电极干扰而诱发严重TR的患者组成了我们的研究小组。TR以重度为主(68%),其次是大面积(21%)和暴发性(11%)。受干扰影响最大的是室间隔心叶。58%的样本显示右心房(RA)严重扩张(RA平均面积为28平方厘米)。三尖瓣环的平均测量值为 42 毫米。量化左心室收缩功能的常规参数平均在正常范围内(TAPSE平均值19毫米,S波10毫米,FAC 41%),而整体左心室应变(RVGLS -15%)和游离壁应变(RVFWLS -19%)均有所降低。心室/肺动脉未耦合的初期程度明显(平均TAPSE/PSAP为0.34,SGLVD/PSAP为0.27%/mmHg):结论:CIED诱导的重度TR患者具有异质性表型,重度RA和三尖瓣环扩张的发生率较高。RVGLS、RVFWLS和动脉心室耦合是早期评估RV收缩功能障碍最敏感的参数。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Phenotype of severe tricuspid regurgitation induced by intracardiac pacing devices.

Introduction and aims: Tricuspid regurgitation (TR) induced by the implantation of cardiac implantable electronic devices (CIED) is an increasingly common cause of severe TR. Our aim was to describe the echocardiographic phenotypic characteristics of CIED-induced severe TR.

Methods: Retrospective cohort study that included patients with severe TR related to CIED diagnosed in the cardiac imaging unit of a Spanish tertiary hospital.

Results: 37 patients with severe TR induced by lead/electrode interference formed our study group. TR was predominantly severe (68%), followed by massive (21%) and torrential (11%). The leaflet most affected by the interference was the septal. 58% of the sample presented severe dilatation of the right atrium (RA) (mean RA area 28cm2). Mean tricuspid annulus measurement was 42mm. The usual parameters for quantifying RV systolic function were on average within the normal range (TAPSE mean 19mm, S' wave 10mm, FAC 41%), while global RV strain (RVGLS -15%) and free wall strain (RVFWLS -19%) were found reduced. An incipient degree of ventricular/pulmonary arterial uncoupling was evident (mean TAPSE/PSAP 0.34, SGLVD/PSAP 0.27%/mmHg).

Conclusions: Our patients with CIED-induced severe TR are characterized by a heterogeneous phenotype with a high prevalence of severe RA and tricuspid annulus dilatation. RVGLS, RVFWLS, and arterial ventricular coupling were the most sensitive parameters for early assessment of RV systolic dysfunction.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Medicina Clinica
Medicina Clinica 医学-医学:内科
CiteScore
3.10
自引率
5.10%
发文量
295
审稿时长
22 days
期刊介绍: Medicina Clínica, fundada en 1943, es una publicación quincenal dedicada a la promoción de la investigación y de la práctica clínica entre los especialistas de la medicina interna, así como otras especialidades. Son características fundamentales de esta publicación el rigor científico y metodológico de sus artículos, la actualidad de los temas y, sobre todo, su sentido práctico, buscando siempre que la información sea de la mayor utilidad en la práctica clínica.
期刊最新文献
Dronedarone pneumonitis: a case report. Dysfunctional insertion of the electronic medical death certificate in the official statistics of causes of death. Ethics and challenges of artificial intelligence in healthcare. How could artificial intelligence improve patient experience in the ambulatory setting? Reflections from the JANUS group. Neuroborreliosis at the region of Asturias, Spain (2009-2022): Analysis of 38 cases.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1