院外心脏骤停院前单平面经食道超声心动图图像质量回顾性研究:单中心试点研究

IF 2.1 3区 医学 Q2 EMERGENCY MEDICINE Prehospital Emergency Care Pub Date : 2024-11-01 DOI:10.1080/10903127.2024.2411720
Kristopher Bianconi, Mark Hanna, Gautam Visveswaran, Reenal Patel, Joseph Pompa, Alec Glucksman, Garrett Cavaliere, Matthew Steenberg, Ammundeep Tagore, Navin Ariyaprakai
{"title":"院外心脏骤停院前单平面经食道超声心动图图像质量回顾性研究:单中心试点研究","authors":"Kristopher Bianconi, Mark Hanna, Gautam Visveswaran, Reenal Patel, Joseph Pompa, Alec Glucksman, Garrett Cavaliere, Matthew Steenberg, Ammundeep Tagore, Navin Ariyaprakai","doi":"10.1080/10903127.2024.2411720","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Out of Hospital Cardiac Arrest (OHCA) is a frequently encountered pathology with resultant poor outcomes in the majority of patients. Echocardiography has been utilized to help guide clinical decision making and monitor effectiveness of resuscitative efforts. Transthoracic echocardiography (TTE) the mainstay of point-of-care ultrasound (POCUS) real time resuscitative imaging has limitations, most notably is the disruption of closed chest compressions. Trans-esophageal echocardiography (TEE) is an emerging technology in emergency care and can potentially overcome these limitations but image quality and accuracy of use in the prehospital environment remains unknown. Our primary objective is to identify the accuracy of Emergency Medical Services (EMS) fellow physicians in performing TEE via the identification of key cardiac structures. Secondarily we assess image quality as well as accuracy on cardiac activity interpretation as compared to TEE-experienced cardiologists.</p><p><strong>Methods: </strong>A pilot study using descriptive analysis of a retrospective case-series with specific focus on inter-rater reliability as well as pragmatic management alterations based on real-time image interpretation by EMS physicians. After focused education, 13 patients were eligible for prehospital TEE who suffering OHCA from July 2022 to June 2023. Ultrasound (US) images were interpreted by EMS fellow physicians and over-read by cardiologists with specific focus on inter-rater reliability. After collection of patients presenting data and US images, analysis was performed.</p><p><strong>Results: </strong>Of 13 patients initially screened, 10 patients were included in a study with a median age of 50 years old (41-70). Three patients were excluded due to equipment malfunction or insufficient image capture. An interrater reliability identified a kappa of 0.96 with respect to identification of cardiac structures and a kappa of 0.65 for identification of cardiac activity.</p><p><strong>Conclusions: </strong>In this small study of prehospital TEE, EMS fellow physicians had high inter-rater reliability in image interpretation pertaining to anatomy and cardiac activity when compared with cardiologists. Further research is needed to determine its efficacy, safety, and widespread application in the prehospital setting.</p>","PeriodicalId":20336,"journal":{"name":"Prehospital Emergency Care","volume":" ","pages":"1-6"},"PeriodicalIF":2.1000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Retrospective Review of the Image Quality of Monoplane Transesophageal Echocardiography in Prehospital Out-of-Hospital Cardiac Arrest: A Single Center Pilot Study.\",\"authors\":\"Kristopher Bianconi, Mark Hanna, Gautam Visveswaran, Reenal Patel, Joseph Pompa, Alec Glucksman, Garrett Cavaliere, Matthew Steenberg, Ammundeep Tagore, Navin Ariyaprakai\",\"doi\":\"10.1080/10903127.2024.2411720\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>Out of Hospital Cardiac Arrest (OHCA) is a frequently encountered pathology with resultant poor outcomes in the majority of patients. Echocardiography has been utilized to help guide clinical decision making and monitor effectiveness of resuscitative efforts. Transthoracic echocardiography (TTE) the mainstay of point-of-care ultrasound (POCUS) real time resuscitative imaging has limitations, most notably is the disruption of closed chest compressions. Trans-esophageal echocardiography (TEE) is an emerging technology in emergency care and can potentially overcome these limitations but image quality and accuracy of use in the prehospital environment remains unknown. Our primary objective is to identify the accuracy of Emergency Medical Services (EMS) fellow physicians in performing TEE via the identification of key cardiac structures. Secondarily we assess image quality as well as accuracy on cardiac activity interpretation as compared to TEE-experienced cardiologists.</p><p><strong>Methods: </strong>A pilot study using descriptive analysis of a retrospective case-series with specific focus on inter-rater reliability as well as pragmatic management alterations based on real-time image interpretation by EMS physicians. After focused education, 13 patients were eligible for prehospital TEE who suffering OHCA from July 2022 to June 2023. Ultrasound (US) images were interpreted by EMS fellow physicians and over-read by cardiologists with specific focus on inter-rater reliability. After collection of patients presenting data and US images, analysis was performed.</p><p><strong>Results: </strong>Of 13 patients initially screened, 10 patients were included in a study with a median age of 50 years old (41-70). Three patients were excluded due to equipment malfunction or insufficient image capture. An interrater reliability identified a kappa of 0.96 with respect to identification of cardiac structures and a kappa of 0.65 for identification of cardiac activity.</p><p><strong>Conclusions: </strong>In this small study of prehospital TEE, EMS fellow physicians had high inter-rater reliability in image interpretation pertaining to anatomy and cardiac activity when compared with cardiologists. Further research is needed to determine its efficacy, safety, and widespread application in the prehospital setting.</p>\",\"PeriodicalId\":20336,\"journal\":{\"name\":\"Prehospital Emergency Care\",\"volume\":\" \",\"pages\":\"1-6\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2024-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Prehospital Emergency Care\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1080/10903127.2024.2411720\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"EMERGENCY MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Prehospital Emergency Care","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/10903127.2024.2411720","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"EMERGENCY MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的:院外心脏骤停(OHCA)是一种经常遇到的病理现象,大多数患者的预后都很差。超声心动图已被用来帮助指导临床决策和监测复苏工作的效果。经胸超声心动图(TTE)是护理点超声(POCUS)实时复苏成像的主要手段,但也有其局限性,最明显的是会破坏闭式胸外按压。经食道超声心动图(TEE)是急救领域的一项新兴技术,有可能克服这些局限性,但在院前环境中使用的图像质量和准确性仍是未知数。我们的主要目标是通过识别关键心脏结构来确定急诊医疗服务 (EMS) 研究员在进行 TEE 时的准确性。其次,与有 TEE 经验的心脏病专家相比,我们将评估图像质量以及心脏活动解读的准确性:方法:这是一项对回顾性病例系列进行描述性分析的试验性研究,重点关注评分者之间的可靠性,以及根据急救医生的实时图像判读对实际管理做出的改变。2022 年 7 月至 2023 年 6 月期间,13 名患者在接受集中教育后符合院前 TEE 的条件,并发生了 OHCA。超声波(US)图像由急救医生进行解读,并由心脏病专家进行复读,重点关注评分者之间的可靠性。在收集了患者陈述数据和超声图像后,进行了分析:在初步筛选出的 13 名患者中,有 10 名患者被纳入研究,他们的中位年龄为 50 岁(41-70 岁)。三名患者因设备故障或图像采集不足而被排除。在识别心脏结构方面,研究人员之间的卡帕值为 0.96,在识别心脏活动方面,卡帕值为 0.65:在这项院前 TEE 的小型研究中,与心脏病专家相比,急救医疗研究员在解剖学和心脏活动的图像解读方面具有很高的评分者间可靠性。要确定其有效性、安全性以及在院前环境中的广泛应用,还需要进一步的研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Retrospective Review of the Image Quality of Monoplane Transesophageal Echocardiography in Prehospital Out-of-Hospital Cardiac Arrest: A Single Center Pilot Study.

Objectives: Out of Hospital Cardiac Arrest (OHCA) is a frequently encountered pathology with resultant poor outcomes in the majority of patients. Echocardiography has been utilized to help guide clinical decision making and monitor effectiveness of resuscitative efforts. Transthoracic echocardiography (TTE) the mainstay of point-of-care ultrasound (POCUS) real time resuscitative imaging has limitations, most notably is the disruption of closed chest compressions. Trans-esophageal echocardiography (TEE) is an emerging technology in emergency care and can potentially overcome these limitations but image quality and accuracy of use in the prehospital environment remains unknown. Our primary objective is to identify the accuracy of Emergency Medical Services (EMS) fellow physicians in performing TEE via the identification of key cardiac structures. Secondarily we assess image quality as well as accuracy on cardiac activity interpretation as compared to TEE-experienced cardiologists.

Methods: A pilot study using descriptive analysis of a retrospective case-series with specific focus on inter-rater reliability as well as pragmatic management alterations based on real-time image interpretation by EMS physicians. After focused education, 13 patients were eligible for prehospital TEE who suffering OHCA from July 2022 to June 2023. Ultrasound (US) images were interpreted by EMS fellow physicians and over-read by cardiologists with specific focus on inter-rater reliability. After collection of patients presenting data and US images, analysis was performed.

Results: Of 13 patients initially screened, 10 patients were included in a study with a median age of 50 years old (41-70). Three patients were excluded due to equipment malfunction or insufficient image capture. An interrater reliability identified a kappa of 0.96 with respect to identification of cardiac structures and a kappa of 0.65 for identification of cardiac activity.

Conclusions: In this small study of prehospital TEE, EMS fellow physicians had high inter-rater reliability in image interpretation pertaining to anatomy and cardiac activity when compared with cardiologists. Further research is needed to determine its efficacy, safety, and widespread application in the prehospital setting.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Prehospital Emergency Care
Prehospital Emergency Care 医学-公共卫生、环境卫生与职业卫生
CiteScore
4.30
自引率
12.50%
发文量
137
审稿时长
1 months
期刊介绍: Prehospital Emergency Care publishes peer-reviewed information relevant to the practice, educational advancement, and investigation of prehospital emergency care, including the following types of articles: Special Contributions - Original Articles - Education and Practice - Preliminary Reports - Case Conferences - Position Papers - Collective Reviews - Editorials - Letters to the Editor - Media Reviews.
期刊最新文献
Key Takeaways and Progress on Leveraging EMS in Overdose Response Among Five Learning Collaborative States. Uses of Fibrinogen Concentrate in Management of Trauma-Induced Coagulopathy in the Prehospital Environment: A Scoping Review. Correlation Between EtCO2 and PCO2 in Patients Undergoing Critical Care Transport. The National Association of EMS Physicians Compendium of Prehospital Trauma Management Position Statements and Resource Documents. Prehospital Trauma Compendium: Fluid Resuscitation in Trauma- a position statement and resource document of NAEMSP.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1