使用两种不同的抗凝剂和基于过氧化物酶活性的比色法测定血清和血浆中牛血红蛋白浓度的差异。

IF 1.2 4区 农林科学 Q3 VETERINARY SCIENCES Veterinary clinical pathology Pub Date : 2024-10-21 DOI:10.1111/vcp.13386
R Schmitt, R Staufenbiel
{"title":"使用两种不同的抗凝剂和基于过氧化物酶活性的比色法测定血清和血浆中牛血红蛋白浓度的差异。","authors":"R Schmitt, R Staufenbiel","doi":"10.1111/vcp.13386","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Haptoglobin (Hp) is an emerging diagnostic marker in cattle, and knowledge of suitable sample types and measurement methods is important.</p><p><strong>Objectives: </strong>The aims of this study were to compare the results of a colorimetric assay (CA) and an ELISA for bovine Hp using serum, EDTA plasma, and lithium-heparinized (LH) plasma, respectively, and to assess the diagnostic potential for puerperal metritis.</p><p><strong>Methods: </strong>In experiment 1, Hp was measured in pooled aliquots of serum (n = 10), EDTA plasma (n = 10), and LH plasma (n = 10) of 100 healthy fresh lactating dairy cows from 10 farms using both the CA and the ELISA. In experiment 2, five healthy and five cows with acute puerperal metritis were sampled, and Hp was determined using both assays for all three sample types. In experiment 3, aliquots of serum and LH plasma from cows in different lactation stages were transferred into plain, EDTA-coated, and LH-coated tubes and mixed before colorimetric analyses. Distilled water was also placed into each tube type and treated similarly.</p><p><strong>Results: </strong>Plasma samples measured with the CA showed on average 2.3 (EDTA) and 2.5 (LH) times higher Hp concentrations compared with serum, whereas no differences were seen with the ELISA results between sample types. Based on a clinical cut-off value, both methods differentiated sick from healthy cows. Haptoglobin measurements with the ELISA were less precise compared with CA measurements due to high dilutions. No influence of the anticoagulants on the CA was observed.</p><p><strong>Conclusions: </strong>Due to measurement discrepancies between serum and plasma, CAs for bovine Hp based on peroxidase activity should be performed with serum, or specific reference ranges for plasma samples should be established. In this study, CA results obtained with LH plasma were more precise than results obtained with EDTA plasma. Both the CA and the ELISA are suitable diagnostic tools for the diagnosis of puerperal metritis, but CA measurements were more precise in this study.</p>","PeriodicalId":23593,"journal":{"name":"Veterinary clinical pathology","volume":null,"pages":null},"PeriodicalIF":1.2000,"publicationDate":"2024-10-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Discrepancies of bovine haptoglobin concentrations between serum and plasma using two different anticoagulants and a colorimetric assay based on peroxidase activity.\",\"authors\":\"R Schmitt, R Staufenbiel\",\"doi\":\"10.1111/vcp.13386\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Haptoglobin (Hp) is an emerging diagnostic marker in cattle, and knowledge of suitable sample types and measurement methods is important.</p><p><strong>Objectives: </strong>The aims of this study were to compare the results of a colorimetric assay (CA) and an ELISA for bovine Hp using serum, EDTA plasma, and lithium-heparinized (LH) plasma, respectively, and to assess the diagnostic potential for puerperal metritis.</p><p><strong>Methods: </strong>In experiment 1, Hp was measured in pooled aliquots of serum (n = 10), EDTA plasma (n = 10), and LH plasma (n = 10) of 100 healthy fresh lactating dairy cows from 10 farms using both the CA and the ELISA. In experiment 2, five healthy and five cows with acute puerperal metritis were sampled, and Hp was determined using both assays for all three sample types. In experiment 3, aliquots of serum and LH plasma from cows in different lactation stages were transferred into plain, EDTA-coated, and LH-coated tubes and mixed before colorimetric analyses. Distilled water was also placed into each tube type and treated similarly.</p><p><strong>Results: </strong>Plasma samples measured with the CA showed on average 2.3 (EDTA) and 2.5 (LH) times higher Hp concentrations compared with serum, whereas no differences were seen with the ELISA results between sample types. Based on a clinical cut-off value, both methods differentiated sick from healthy cows. Haptoglobin measurements with the ELISA were less precise compared with CA measurements due to high dilutions. No influence of the anticoagulants on the CA was observed.</p><p><strong>Conclusions: </strong>Due to measurement discrepancies between serum and plasma, CAs for bovine Hp based on peroxidase activity should be performed with serum, or specific reference ranges for plasma samples should be established. In this study, CA results obtained with LH plasma were more precise than results obtained with EDTA plasma. Both the CA and the ELISA are suitable diagnostic tools for the diagnosis of puerperal metritis, but CA measurements were more precise in this study.</p>\",\"PeriodicalId\":23593,\"journal\":{\"name\":\"Veterinary clinical pathology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2024-10-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Veterinary clinical pathology\",\"FirstCategoryId\":\"97\",\"ListUrlMain\":\"https://doi.org/10.1111/vcp.13386\",\"RegionNum\":4,\"RegionCategory\":\"农林科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"VETERINARY SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Veterinary clinical pathology","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.1111/vcp.13386","RegionNum":4,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

摘要

背景:合血红蛋白(Hp)是一种新兴的牛诊断标记物,了解合适的样品类型和测量方法非常重要:本研究的目的是比较分别使用血清、EDTA血浆和锂肝素化(LH)血浆测定牛Hp的比色法(CA)和酶联免疫吸附法的结果,并评估其对产褥期甲沟炎的诊断潜力:在实验 1 中,使用 CA 和 ELISA 检测 10 个牧场 100 头健康新鲜泌乳奶牛的血清(n = 10)、EDTA 血浆(n = 10)和 LH 血浆(n = 10)中的 Hp。在实验 2 中,对 5 头健康奶牛和 5 头患有急性产褥期甲沟炎的奶牛进行采样,并使用两种检测方法对所有三种样本类型的 Hp 进行测定。在实验 3 中,将不同泌乳阶段奶牛的血清和 LH 血浆等分移入普通试管、EDTA 涂层试管和 LH 涂层试管中,并在比色分析前混合。蒸馏水也被放入每种试管中,并进行类似处理:结果:与血清相比,用CA测定的血浆样本中的Hp浓度平均高出2.3倍(EDTA)和2.5倍(LH),而不同类型样本的ELISA结果没有差异。根据临床临界值,两种方法都能区分患病奶牛和健康奶牛。由于稀释度较高,用酶联免疫吸附法测定血红蛋白的精确度低于用CA法测定血红蛋白的精确度。抗凝剂对CA没有影响:结论:由于血清和血浆之间存在测量差异,基于过氧化物酶活性的牛 Hp CA 应使用血清进行,或为血浆样本建立特定的参考范围。在本研究中,用 LH 血浆获得的 CA 结果比用 EDTA 血浆获得的结果更精确。CA 和 ELISA 都是诊断产褥期甲胎蛋白炎的合适工具,但本研究中 CA 的测量结果更为精确。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Discrepancies of bovine haptoglobin concentrations between serum and plasma using two different anticoagulants and a colorimetric assay based on peroxidase activity.

Background: Haptoglobin (Hp) is an emerging diagnostic marker in cattle, and knowledge of suitable sample types and measurement methods is important.

Objectives: The aims of this study were to compare the results of a colorimetric assay (CA) and an ELISA for bovine Hp using serum, EDTA plasma, and lithium-heparinized (LH) plasma, respectively, and to assess the diagnostic potential for puerperal metritis.

Methods: In experiment 1, Hp was measured in pooled aliquots of serum (n = 10), EDTA plasma (n = 10), and LH plasma (n = 10) of 100 healthy fresh lactating dairy cows from 10 farms using both the CA and the ELISA. In experiment 2, five healthy and five cows with acute puerperal metritis were sampled, and Hp was determined using both assays for all three sample types. In experiment 3, aliquots of serum and LH plasma from cows in different lactation stages were transferred into plain, EDTA-coated, and LH-coated tubes and mixed before colorimetric analyses. Distilled water was also placed into each tube type and treated similarly.

Results: Plasma samples measured with the CA showed on average 2.3 (EDTA) and 2.5 (LH) times higher Hp concentrations compared with serum, whereas no differences were seen with the ELISA results between sample types. Based on a clinical cut-off value, both methods differentiated sick from healthy cows. Haptoglobin measurements with the ELISA were less precise compared with CA measurements due to high dilutions. No influence of the anticoagulants on the CA was observed.

Conclusions: Due to measurement discrepancies between serum and plasma, CAs for bovine Hp based on peroxidase activity should be performed with serum, or specific reference ranges for plasma samples should be established. In this study, CA results obtained with LH plasma were more precise than results obtained with EDTA plasma. Both the CA and the ELISA are suitable diagnostic tools for the diagnosis of puerperal metritis, but CA measurements were more precise in this study.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Veterinary clinical pathology
Veterinary clinical pathology 农林科学-兽医学
CiteScore
1.70
自引率
16.70%
发文量
133
审稿时长
18-36 weeks
期刊介绍: Veterinary Clinical Pathology is the official journal of the American Society for Veterinary Clinical Pathology (ASVCP) and the European Society of Veterinary Clinical Pathology (ESVCP). The journal''s mission is to provide an international forum for communication and discussion of scientific investigations and new developments that advance the art and science of laboratory diagnosis in animals. Veterinary Clinical Pathology welcomes original experimental research and clinical contributions involving domestic, laboratory, avian, and wildlife species in the areas of hematology, hemostasis, immunopathology, clinical chemistry, cytopathology, surgical pathology, toxicology, endocrinology, laboratory and analytical techniques, instrumentation, quality assurance, and clinical pathology education.
期刊最新文献
What is your diagnosis: Acute hemolysis in a Limousin bull. New strategies to classify canine pleural effusions and the diagnostic value of acute phase proteins, amylase, and adenosine deaminase in pleural exudates. What is your diagnosis? Intra-abdominal mass in a dog. What's your diagnosis? Circumferential small intestinal mass in a cat. Detection of renal tubular transporter proteins in canine urinary extracellular vesicles using liquid chromatography-tandem mass spectrometry.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1