Sang-Min Lee, Tae-Gon Jung, Won-Hyeon Kim, Bongju Kim, Jee-Ho Lee
{"title":"腓骨游离瓣下颌骨体重建中羟基磷灰石/聚乳酸固定的生物力学评估:结合材料特性和咀嚼功能评估的有限元分析。","authors":"Sang-Min Lee, Tae-Gon Jung, Won-Hyeon Kim, Bongju Kim, Jee-Ho Lee","doi":"10.3390/bioengineering11101009","DOIUrl":null,"url":null,"abstract":"<p><p>In reconstructive surgery following partial mandibulectomy, the biomechanical integrity of the fibula free flap applied to the remaining mandibular region directly influences the prognosis of the surgery. The purpose of this study is to evaluate the biomechanical integrity of two fixation materials [titanium (Ti) and hydroxyapatite/poly-L-lactide (HA-PLLA)]. In this study, we simulated the mechanical properties of miniplate and screw fixations in two different systems by finite element analysis. A three-dimensional mandibular model was constructed and a fibula free flap and reconstruction surface were designed. The anterior and posterior end of the free flap was positioned with two miniplates and two additional miniplates were applied to the angled area of the fibula. The masticatory loading was applied considering seven principal muscles. The peak von Mises stress (PVMS) distribution, size of fixation deformation, principal stresses on bones, and gap opening size were measured to evaluate the material properties of the fixation. In the evaluation of properties, superior results were observed with both fixation methods immediately after surgery. However, after the formation of callus between bone segments at 2 months, the performance of Ti fixation decreased over time and the differences between the two fixations became minimal by 6 months after surgery. The result of the study implies the positive clinical potential of the HA-PLLA fixation system applied in fibula free flap reconstruction.</p>","PeriodicalId":8874,"journal":{"name":"Bioengineering","volume":"11 10","pages":""},"PeriodicalIF":3.8000,"publicationDate":"2024-10-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11505077/pdf/","citationCount":"0","resultStr":"{\"title\":\"Biomechanical Evaluation of Hydroxyapatite/poly-l-lactide Fixation in Mandibular Body Reconstruction with Fibula Free Flap: A Finite Element Analysis Incorporating Material Properties and Masticatory Function Evaluation.\",\"authors\":\"Sang-Min Lee, Tae-Gon Jung, Won-Hyeon Kim, Bongju Kim, Jee-Ho Lee\",\"doi\":\"10.3390/bioengineering11101009\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>In reconstructive surgery following partial mandibulectomy, the biomechanical integrity of the fibula free flap applied to the remaining mandibular region directly influences the prognosis of the surgery. The purpose of this study is to evaluate the biomechanical integrity of two fixation materials [titanium (Ti) and hydroxyapatite/poly-L-lactide (HA-PLLA)]. In this study, we simulated the mechanical properties of miniplate and screw fixations in two different systems by finite element analysis. A three-dimensional mandibular model was constructed and a fibula free flap and reconstruction surface were designed. The anterior and posterior end of the free flap was positioned with two miniplates and two additional miniplates were applied to the angled area of the fibula. The masticatory loading was applied considering seven principal muscles. The peak von Mises stress (PVMS) distribution, size of fixation deformation, principal stresses on bones, and gap opening size were measured to evaluate the material properties of the fixation. In the evaluation of properties, superior results were observed with both fixation methods immediately after surgery. However, after the formation of callus between bone segments at 2 months, the performance of Ti fixation decreased over time and the differences between the two fixations became minimal by 6 months after surgery. The result of the study implies the positive clinical potential of the HA-PLLA fixation system applied in fibula free flap reconstruction.</p>\",\"PeriodicalId\":8874,\"journal\":{\"name\":\"Bioengineering\",\"volume\":\"11 10\",\"pages\":\"\"},\"PeriodicalIF\":3.8000,\"publicationDate\":\"2024-10-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11505077/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Bioengineering\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.3390/bioengineering11101009\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bioengineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3390/bioengineering11101009","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
Biomechanical Evaluation of Hydroxyapatite/poly-l-lactide Fixation in Mandibular Body Reconstruction with Fibula Free Flap: A Finite Element Analysis Incorporating Material Properties and Masticatory Function Evaluation.
In reconstructive surgery following partial mandibulectomy, the biomechanical integrity of the fibula free flap applied to the remaining mandibular region directly influences the prognosis of the surgery. The purpose of this study is to evaluate the biomechanical integrity of two fixation materials [titanium (Ti) and hydroxyapatite/poly-L-lactide (HA-PLLA)]. In this study, we simulated the mechanical properties of miniplate and screw fixations in two different systems by finite element analysis. A three-dimensional mandibular model was constructed and a fibula free flap and reconstruction surface were designed. The anterior and posterior end of the free flap was positioned with two miniplates and two additional miniplates were applied to the angled area of the fibula. The masticatory loading was applied considering seven principal muscles. The peak von Mises stress (PVMS) distribution, size of fixation deformation, principal stresses on bones, and gap opening size were measured to evaluate the material properties of the fixation. In the evaluation of properties, superior results were observed with both fixation methods immediately after surgery. However, after the formation of callus between bone segments at 2 months, the performance of Ti fixation decreased over time and the differences between the two fixations became minimal by 6 months after surgery. The result of the study implies the positive clinical potential of the HA-PLLA fixation system applied in fibula free flap reconstruction.
期刊介绍:
Aims
Bioengineering (ISSN 2306-5354) provides an advanced forum for the science and technology of bioengineering. It publishes original research papers, comprehensive reviews, communications and case reports. Our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible. All aspects of bioengineering are welcomed from theoretical concepts to education and applications. There is no restriction on the length of the papers. The full experimental details must be provided so that the results can be reproduced. There are, in addition, four key features of this Journal:
● We are introducing a new concept in scientific and technical publications “The Translational Case Report in Bioengineering”. It is a descriptive explanatory analysis of a transformative or translational event. Understanding that the goal of bioengineering scholarship is to advance towards a transformative or clinical solution to an identified transformative/clinical need, the translational case report is used to explore causation in order to find underlying principles that may guide other similar transformative/translational undertakings.
● Manuscripts regarding research proposals and research ideas will be particularly welcomed.
● Electronic files and software regarding the full details of the calculation and experimental procedure, if unable to be published in a normal way, can be deposited as supplementary material.
● We also accept manuscripts communicating to a broader audience with regard to research projects financed with public funds.
Scope
● Bionics and biological cybernetics: implantology; bio–abio interfaces
● Bioelectronics: wearable electronics; implantable electronics; “more than Moore” electronics; bioelectronics devices
● Bioprocess and biosystems engineering and applications: bioprocess design; biocatalysis; bioseparation and bioreactors; bioinformatics; bioenergy; etc.
● Biomolecular, cellular and tissue engineering and applications: tissue engineering; chromosome engineering; embryo engineering; cellular, molecular and synthetic biology; metabolic engineering; bio-nanotechnology; micro/nano technologies; genetic engineering; transgenic technology
● Biomedical engineering and applications: biomechatronics; biomedical electronics; biomechanics; biomaterials; biomimetics; biomedical diagnostics; biomedical therapy; biomedical devices; sensors and circuits; biomedical imaging and medical information systems; implants and regenerative medicine; neurotechnology; clinical engineering; rehabilitation engineering
● Biochemical engineering and applications: metabolic pathway engineering; modeling and simulation
● Translational bioengineering