结肠胶囊内窥镜检查中的肠道清洁质量评估:参考标准是什么?

IF 4.3 3区 材料科学 Q1 ENGINEERING, ELECTRICAL & ELECTRONIC ACS Applied Electronic Materials Pub Date : 2024-10-23 eCollection Date: 2024-01-01 DOI:10.1177/17562848241290256
Benedicte Schelde-Olesen, Anastasios Koulaouzidis, Ulrik Deding, Ervin Toth, Konstantinos John Dabos, Abraham Eliakim, Cristina Carretero, Begoña González-Suárez, Xavier Dray, Thomas de Lange, Hanneke Beaumont, Emanuele Rondonotti, Uri Kopylov, Pierre Ellul, Enrique Pérez-Cuadrado-Robles, Alexander Robertson, Irene Stenfors, Alejandro Bojorquez, Stefania Piccirelli, Gitte Grunnet Raabe, Reuma Margalit-Yehuda, Isabel Barba, Giulia Scardino, Salome Ouazana, Thomas Bjørsum-Meyer
{"title":"结肠胶囊内窥镜检查中的肠道清洁质量评估:参考标准是什么?","authors":"Benedicte Schelde-Olesen, Anastasios Koulaouzidis, Ulrik Deding, Ervin Toth, Konstantinos John Dabos, Abraham Eliakim, Cristina Carretero, Begoña González-Suárez, Xavier Dray, Thomas de Lange, Hanneke Beaumont, Emanuele Rondonotti, Uri Kopylov, Pierre Ellul, Enrique Pérez-Cuadrado-Robles, Alexander Robertson, Irene Stenfors, Alejandro Bojorquez, Stefania Piccirelli, Gitte Grunnet Raabe, Reuma Margalit-Yehuda, Isabel Barba, Giulia Scardino, Salome Ouazana, Thomas Bjørsum-Meyer","doi":"10.1177/17562848241290256","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The diagnostic accuracy of colon capsule endoscopy (CCE) depends on a well-cleansed bowel. Evaluating the cleansing quality can be difficult with a substantial interobserver variation.</p><p><strong>Objectives: </strong>Our primary aim was to establish a standard of agreement for bowel cleansing in CCE based on evaluations by expert readers. Then, we aimed to investigate the interobserver agreement on bowel cleansing.</p><p><strong>Design: </strong>We conducted an interobserver agreement study on bowel cleansing quality.</p><p><strong>Methods: </strong>Readers with different experience levels in CCE and colonoscopy evaluated bowel cleansing quality on the Leighton-Rex scale and Colon Capsule CLEansing Assessment and Report (CC-CLEAR), respectively. All evaluations were reported on an image level. A total of 24 readers rated 500 images on each scale.</p><p><strong>Results: </strong>An expert opinion-based agreement standard could be set for poor and excellent cleansing but not for the spectrum in between, as the experts agreed on only a limited number of images representing fair and good cleansing. The overall interobserver agreement on the Leighton-Rex full scale was good (intraclass correlation coefficient (ICC) 0.84, 95% CI (0.82-0.85)) and remained good when stratified by experience level. On the full CC-CLEAR scale, the overall agreement was moderate (ICC 0.62, 95% CI (0.59-0.65)) and remained so when stratified by experience level.</p><p><strong>Conclusion: </strong>The interobserver agreement was good for the Leighton-Rex scale and moderate for CC-CLEAR, irrespective of the reader's experience level. It was not possible to establish an expert-opinion standard of agreement for cleansing quality in CCE images. Dedicated training in using the scales may improve agreement and enable future algorithm calibration for artificial intelligence supported cleansing evaluation.</p><p><strong>Trial registration: </strong>All included images were derived from the CAREforCOLON 2015 trial (Registered with The Regional Health Research Ethics Committee (Registration number: S-20190100), the Danish data protection agency (Ref. 19/29858), and ClinicalTrials.gov (registration number: NCT04049357)).</p>","PeriodicalId":3,"journal":{"name":"ACS Applied Electronic Materials","volume":null,"pages":null},"PeriodicalIF":4.3000,"publicationDate":"2024-10-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11500223/pdf/","citationCount":"0","resultStr":"{\"title\":\"Bowel cleansing quality evaluation in colon capsule endoscopy: what is the reference standard?\",\"authors\":\"Benedicte Schelde-Olesen, Anastasios Koulaouzidis, Ulrik Deding, Ervin Toth, Konstantinos John Dabos, Abraham Eliakim, Cristina Carretero, Begoña González-Suárez, Xavier Dray, Thomas de Lange, Hanneke Beaumont, Emanuele Rondonotti, Uri Kopylov, Pierre Ellul, Enrique Pérez-Cuadrado-Robles, Alexander Robertson, Irene Stenfors, Alejandro Bojorquez, Stefania Piccirelli, Gitte Grunnet Raabe, Reuma Margalit-Yehuda, Isabel Barba, Giulia Scardino, Salome Ouazana, Thomas Bjørsum-Meyer\",\"doi\":\"10.1177/17562848241290256\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>The diagnostic accuracy of colon capsule endoscopy (CCE) depends on a well-cleansed bowel. Evaluating the cleansing quality can be difficult with a substantial interobserver variation.</p><p><strong>Objectives: </strong>Our primary aim was to establish a standard of agreement for bowel cleansing in CCE based on evaluations by expert readers. Then, we aimed to investigate the interobserver agreement on bowel cleansing.</p><p><strong>Design: </strong>We conducted an interobserver agreement study on bowel cleansing quality.</p><p><strong>Methods: </strong>Readers with different experience levels in CCE and colonoscopy evaluated bowel cleansing quality on the Leighton-Rex scale and Colon Capsule CLEansing Assessment and Report (CC-CLEAR), respectively. All evaluations were reported on an image level. A total of 24 readers rated 500 images on each scale.</p><p><strong>Results: </strong>An expert opinion-based agreement standard could be set for poor and excellent cleansing but not for the spectrum in between, as the experts agreed on only a limited number of images representing fair and good cleansing. The overall interobserver agreement on the Leighton-Rex full scale was good (intraclass correlation coefficient (ICC) 0.84, 95% CI (0.82-0.85)) and remained good when stratified by experience level. On the full CC-CLEAR scale, the overall agreement was moderate (ICC 0.62, 95% CI (0.59-0.65)) and remained so when stratified by experience level.</p><p><strong>Conclusion: </strong>The interobserver agreement was good for the Leighton-Rex scale and moderate for CC-CLEAR, irrespective of the reader's experience level. It was not possible to establish an expert-opinion standard of agreement for cleansing quality in CCE images. Dedicated training in using the scales may improve agreement and enable future algorithm calibration for artificial intelligence supported cleansing evaluation.</p><p><strong>Trial registration: </strong>All included images were derived from the CAREforCOLON 2015 trial (Registered with The Regional Health Research Ethics Committee (Registration number: S-20190100), the Danish data protection agency (Ref. 19/29858), and ClinicalTrials.gov (registration number: NCT04049357)).</p>\",\"PeriodicalId\":3,\"journal\":{\"name\":\"ACS Applied Electronic Materials\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.3000,\"publicationDate\":\"2024-10-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11500223/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Electronic Materials\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/17562848241290256\",\"RegionNum\":3,\"RegionCategory\":\"材料科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Electronic Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/17562848241290256","RegionNum":3,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

摘要

背景:结肠胶囊内窥镜(CCE)诊断的准确性取决于肠道是否清洁干净。评估肠道清洁质量很困难,观察者之间的差异很大:我们的主要目的是根据专家读者的评价,为 CCE 中的肠道清洁建立一个一致标准。然后,我们旨在调查观察者之间在肠道清洁方面的一致性:设计:我们进行了一项关于肠道清洁质量的观察者间一致性研究:方法:在 CCE 和结肠镜检查方面具有不同经验水平的阅读者分别根据 Leighton-Rex 量表和结肠胶囊清洁评估和报告(CC-CLEAR)对肠道清洁质量进行评估。所有评价均以图像为单位进行报告。共有 24 位读者对每种量表的 500 张图像进行了评分:结果:基于专家意见的一致标准可用于较差和极佳的清洁度,但不能用于介于两者之间的范围,因为专家们只对代表一般和良好清洁度的有限数量的图像达成一致。Leighton-Rex全量表的总体观察者间一致性良好(类内相关系数(ICC)0.84,95% CI (0.82-0.85)),按经验水平分层后,一致性依然良好。在完整的 CC-CLEAR 量表中,总体一致性为中等(ICC 0.62,95% CI (0.59-0.65)),按经验水平分层后仍为中等:结论:无论读者的经验水平如何,Leighton-Rex量表的观察者间一致性良好,CC-CLEAR量表的观察者间一致性中等。对于 CCE 图像的清洁质量,无法建立专家意见一致的标准。使用量表的专门培训可能会提高一致性,并使未来人工智能支持的清洁评估算法校准成为可能:所有纳入的图像均来自 CAREforCOLON 2015 试验(已在地区健康研究伦理委员会(注册号:S-20190100)、丹麦数据保护机构(编号:19/29858)和 ClinicalTrials.gov(注册号:NCT04049357)注册)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Bowel cleansing quality evaluation in colon capsule endoscopy: what is the reference standard?

Background: The diagnostic accuracy of colon capsule endoscopy (CCE) depends on a well-cleansed bowel. Evaluating the cleansing quality can be difficult with a substantial interobserver variation.

Objectives: Our primary aim was to establish a standard of agreement for bowel cleansing in CCE based on evaluations by expert readers. Then, we aimed to investigate the interobserver agreement on bowel cleansing.

Design: We conducted an interobserver agreement study on bowel cleansing quality.

Methods: Readers with different experience levels in CCE and colonoscopy evaluated bowel cleansing quality on the Leighton-Rex scale and Colon Capsule CLEansing Assessment and Report (CC-CLEAR), respectively. All evaluations were reported on an image level. A total of 24 readers rated 500 images on each scale.

Results: An expert opinion-based agreement standard could be set for poor and excellent cleansing but not for the spectrum in between, as the experts agreed on only a limited number of images representing fair and good cleansing. The overall interobserver agreement on the Leighton-Rex full scale was good (intraclass correlation coefficient (ICC) 0.84, 95% CI (0.82-0.85)) and remained good when stratified by experience level. On the full CC-CLEAR scale, the overall agreement was moderate (ICC 0.62, 95% CI (0.59-0.65)) and remained so when stratified by experience level.

Conclusion: The interobserver agreement was good for the Leighton-Rex scale and moderate for CC-CLEAR, irrespective of the reader's experience level. It was not possible to establish an expert-opinion standard of agreement for cleansing quality in CCE images. Dedicated training in using the scales may improve agreement and enable future algorithm calibration for artificial intelligence supported cleansing evaluation.

Trial registration: All included images were derived from the CAREforCOLON 2015 trial (Registered with The Regional Health Research Ethics Committee (Registration number: S-20190100), the Danish data protection agency (Ref. 19/29858), and ClinicalTrials.gov (registration number: NCT04049357)).

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
7.20
自引率
4.30%
发文量
567
期刊最新文献
Hyperbaric oxygen treatment promotes tendon-bone interface healing in a rabbit model of rotator cuff tears. Oxygen-ozone therapy for myocardial ischemic stroke and cardiovascular disorders. Comparative study on the anti-inflammatory and protective effects of different oxygen therapy regimens on lipopolysaccharide-induced acute lung injury in mice. Heme oxygenase/carbon monoxide system and development of the heart. Hyperbaric oxygen for moderate-to-severe traumatic brain injury: outcomes 5-8 years after injury.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1