种植体设计对同时引导骨再生治疗开裂缺损结果的影响:系统回顾与元分析

IF 4.1 4区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE Journal of Evidence-Based Dental Practice Pub Date : 2024-08-16 DOI:10.1016/j.jebdp.2024.102033
Bernadette Quah , Ali Sulaiman Al Yousef , Clement Wei Ming Lai , Raymond Chung Wen Wong , Ren Jie Jacob Chew
{"title":"种植体设计对同时引导骨再生治疗开裂缺损结果的影响:系统回顾与元分析","authors":"Bernadette Quah ,&nbsp;Ali Sulaiman Al Yousef ,&nbsp;Clement Wei Ming Lai ,&nbsp;Raymond Chung Wen Wong ,&nbsp;Ren Jie Jacob Chew","doi":"10.1016/j.jebdp.2024.102033","DOIUrl":null,"url":null,"abstract":"<div><h3>Objective</h3><div>This systematic review and meta-analysis aimed to determine the implications of implant design on the outcomes of simultaneous guided bone regeneration (GBR) to correct dehiscence defects.</div></div><div><h3>Methods</h3><div>A structured search strategy was applied to MEDLINE (PubMed), Cochrane Library, and Embase, to identify prospective clinical trials involving implants with simultaneous GBR to correct dehiscence defects. Data regarding implant characteristics, GBR materials, as well as dehiscence defect dimensions at implant placement and surgical re-entry was collected. Meta-analyses were performed to estimate the pooled mean for (1) baseline dehiscence defect dimensions, (2) changes in defect dimensions at re-entry, and (3) prevalence of complete defect resolution.</div></div><div><h3>Results</h3><div>4298 unique records were identified, of which 21 studies with 680 implants were included. Despite having comparable baseline defect dimensions, greater height gains were achieved by implants with machined collars (MC) than noncollared (NC) implants (4.40 mm, 95% CI [3.70, 5.11] and 3.23 mm, 95% CI [2.72, 3.75] respectively), with significant subgroup differences (<em>P</em> &lt; .01). Specifically, superior outcomes were observed for MC with space-maintaining geometries. However, there were no significant differences in the changes in defect width, prevalence of complete defect resolution, or the prevalence of postsurgical complication rates (<em>P</em> = .15, .54, and .18 respectively).</div></div><div><h3>Conclusions</h3><div>The regenerative outcomes of GBR were influenced by the implant design. Space-maintaining machined collars provide a tenting effect that improves vertical bone gain. While additional research is required to ascertain these findings and integrate choices regarding implant design into clinical decision-making, clinicians may consider replicating this effect to enhance treatment outcomes.</div></div>","PeriodicalId":48736,"journal":{"name":"Journal of Evidence-Based Dental Practice","volume":"24 4","pages":"Article 102033"},"PeriodicalIF":4.1000,"publicationDate":"2024-08-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Impact of Implant Design on Outcomes of Simultaneous Guided Bone Regeneration for Dehiscence Defects: A Systematic Review and Meta-Analysis\",\"authors\":\"Bernadette Quah ,&nbsp;Ali Sulaiman Al Yousef ,&nbsp;Clement Wei Ming Lai ,&nbsp;Raymond Chung Wen Wong ,&nbsp;Ren Jie Jacob Chew\",\"doi\":\"10.1016/j.jebdp.2024.102033\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Objective</h3><div>This systematic review and meta-analysis aimed to determine the implications of implant design on the outcomes of simultaneous guided bone regeneration (GBR) to correct dehiscence defects.</div></div><div><h3>Methods</h3><div>A structured search strategy was applied to MEDLINE (PubMed), Cochrane Library, and Embase, to identify prospective clinical trials involving implants with simultaneous GBR to correct dehiscence defects. Data regarding implant characteristics, GBR materials, as well as dehiscence defect dimensions at implant placement and surgical re-entry was collected. Meta-analyses were performed to estimate the pooled mean for (1) baseline dehiscence defect dimensions, (2) changes in defect dimensions at re-entry, and (3) prevalence of complete defect resolution.</div></div><div><h3>Results</h3><div>4298 unique records were identified, of which 21 studies with 680 implants were included. Despite having comparable baseline defect dimensions, greater height gains were achieved by implants with machined collars (MC) than noncollared (NC) implants (4.40 mm, 95% CI [3.70, 5.11] and 3.23 mm, 95% CI [2.72, 3.75] respectively), with significant subgroup differences (<em>P</em> &lt; .01). Specifically, superior outcomes were observed for MC with space-maintaining geometries. However, there were no significant differences in the changes in defect width, prevalence of complete defect resolution, or the prevalence of postsurgical complication rates (<em>P</em> = .15, .54, and .18 respectively).</div></div><div><h3>Conclusions</h3><div>The regenerative outcomes of GBR were influenced by the implant design. Space-maintaining machined collars provide a tenting effect that improves vertical bone gain. While additional research is required to ascertain these findings and integrate choices regarding implant design into clinical decision-making, clinicians may consider replicating this effect to enhance treatment outcomes.</div></div>\",\"PeriodicalId\":48736,\"journal\":{\"name\":\"Journal of Evidence-Based Dental Practice\",\"volume\":\"24 4\",\"pages\":\"Article 102033\"},\"PeriodicalIF\":4.1000,\"publicationDate\":\"2024-08-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Evidence-Based Dental Practice\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1532338224000836\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Evidence-Based Dental Practice","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1532338224000836","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

本系统综述和荟萃分析旨在确定种植体设计对同步引导骨再生(GBR)矫正开裂缺损结果的影响。方法在 MEDLINE (PubMed)、Cochrane Library 和 Embase 中采用结构化检索策略,以确定涉及种植体同步 GBR 矫正开裂缺损的前瞻性临床试验。收集了有关植入物特征、GBR 材料以及植入物植入和手术再入时的开裂缺损尺寸的数据。研究人员进行了 Meta 分析,以估算 (1) 基线开裂缺损尺寸、(2) 再次手术时缺损尺寸的变化以及 (3) 缺损完全愈合率的汇总平均值。尽管基线缺损尺寸相当,但与无领(NC)种植体(分别为 4.40 mm,95% CI [3.70,5.11] 和 3.23 mm,95% CI [2.72,3.75])相比,加工领(MC)种植体的高度增加幅度更大,亚组差异显著(P < .01)。具体而言,采用空间保持几何形状的 MC 治疗效果更佳。结论 GBR 的再生效果受植入物设计的影响。保持空间的机加工基台可提供帐篷效应,改善垂直骨增量。虽然还需要更多的研究来确定这些发现,并将有关种植体设计的选择纳入临床决策,但临床医生可以考虑复制这种效果,以提高治疗效果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Impact of Implant Design on Outcomes of Simultaneous Guided Bone Regeneration for Dehiscence Defects: A Systematic Review and Meta-Analysis

Objective

This systematic review and meta-analysis aimed to determine the implications of implant design on the outcomes of simultaneous guided bone regeneration (GBR) to correct dehiscence defects.

Methods

A structured search strategy was applied to MEDLINE (PubMed), Cochrane Library, and Embase, to identify prospective clinical trials involving implants with simultaneous GBR to correct dehiscence defects. Data regarding implant characteristics, GBR materials, as well as dehiscence defect dimensions at implant placement and surgical re-entry was collected. Meta-analyses were performed to estimate the pooled mean for (1) baseline dehiscence defect dimensions, (2) changes in defect dimensions at re-entry, and (3) prevalence of complete defect resolution.

Results

4298 unique records were identified, of which 21 studies with 680 implants were included. Despite having comparable baseline defect dimensions, greater height gains were achieved by implants with machined collars (MC) than noncollared (NC) implants (4.40 mm, 95% CI [3.70, 5.11] and 3.23 mm, 95% CI [2.72, 3.75] respectively), with significant subgroup differences (P < .01). Specifically, superior outcomes were observed for MC with space-maintaining geometries. However, there were no significant differences in the changes in defect width, prevalence of complete defect resolution, or the prevalence of postsurgical complication rates (P = .15, .54, and .18 respectively).

Conclusions

The regenerative outcomes of GBR were influenced by the implant design. Space-maintaining machined collars provide a tenting effect that improves vertical bone gain. While additional research is required to ascertain these findings and integrate choices regarding implant design into clinical decision-making, clinicians may consider replicating this effect to enhance treatment outcomes.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Evidence-Based Dental Practice
Journal of Evidence-Based Dental Practice DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
6.00
自引率
16.70%
发文量
105
审稿时长
28 days
期刊介绍: The Journal of Evidence-Based Dental Practice presents timely original articles, as well as reviews of articles on the results and outcomes of clinical procedures and treatment. The Journal advocates the use or rejection of a procedure based on solid, clinical evidence found in literature. The Journal''s dynamic operating principles are explicitness in process and objectives, publication of the highest-quality reviews and original articles, and an emphasis on objectivity.
期刊最新文献
POSTOPERATIVE STABILITY OF AESTHETIC OUTCOMES FOLLOWING RESIN INFILTRATION OF HYPOMINERALISED AND DEMINERALISED ENAMEL LESIONS: A SYSTEMATIC REVIEW HYALURONIC ACID INJECTION MAY BE EFFECTIVE FOR RECONSTRUCTION OF MILD TO MODERATE LOSS OF INTERDENTAL PAPILLA IN ADULT PATIENTS IN THE SHORT TERM CAD/CAM-FABRICATED RPD FRAMEWORKS SHOW LOWER FIT ACCURACY COMPARED TO CONVENTIONAL CASTING, WITH INDIRECT 3D PRINTING OFFERING COMPARABLE RESULTS ORAL CARE AND DENTAL INTERVENTIONS SHOW MIXED AND UNCLEAR EFFECTS ON COGNITIVE FUNCTION ARTIFICIAL INTELLIGENCE IN DENTAL SHADE-MATCHING SHOWS PROMISING POTENTIAL FOR PRECISION IN RESTORATIVE DENTISTRY, THOUGH REQUIRING FURTHER IMPROVEMENT
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1