髋关节置换术后血液中的金属离子水平:两种不同植入物的比较

IF 1.5 Q3 ORTHOPEDICS Arthroplasty Today Pub Date : 2024-10-30 DOI:10.1016/j.artd.2024.101555
Renee Ren BA, Ryan Cheng BA, Andrew Jordan MS, Jonathan Spaan MS, Rachelle Hornick MPH, Walter L. Taylor IV MPhil, Edwin P. Su MD
{"title":"髋关节置换术后血液中的金属离子水平:两种不同植入物的比较","authors":"Renee Ren BA,&nbsp;Ryan Cheng BA,&nbsp;Andrew Jordan MS,&nbsp;Jonathan Spaan MS,&nbsp;Rachelle Hornick MPH,&nbsp;Walter L. Taylor IV MPhil,&nbsp;Edwin P. Su MD","doi":"10.1016/j.artd.2024.101555","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>While hip resurfacing arthroplasty has been shown to be an effective prosthetic solution for end-stage osteoarthritis, prior studies have also reported an increasing concern regarding blood metal ion levels following the use of metal-on-metal articulations. The purpose of this study was to compare early and midterm blood metal ion levels to functional outcomes and implant survivorship for patients treated with the Birmingham Hip Resurfacing (BHR) implant system and the ReCap Magnum.</div></div><div><h3>Methods</h3><div>A retrospective review identified 104 patients who underwent 134 hip resurfacing arthroplasties using BHR (n = 67) and ReCap (n = 67) at a single institution between 2006 and 2018. ReCap and BHR patients were matched 1:1 by sex, femoral head and acetabular cup sizes, age, and year of surgery. The primary outcome of interest was cobalt (Co) and chromium (Cr) ion levels.</div></div><div><h3>Results</h3><div>The ReCap cohort had lower median metal ion levels compared to the BHR cohort at 1-2 y (Co: 1.5 vs 1.9 parts per billion [ppb], <em>P</em> = .018; Cr: 1.3 vs 2.8 ppb, <em>P</em> = .008) and 3-5 y (Co: 1.1 vs 1.9 ppb, <em>P</em> = .001; Cr: 1.2 vs 2.2 ppb, <em>P</em> = .003) after surgery. Correlation analysis showed no significant associations between Co and Cr ion levels and pre- and postoperative patient-reported outcomes. Indications for revision differed between groups. Three BHR hips were revised due to adverse reactions to metal debris, whereas 2 ReCap hips required revisions: one for instability and another for periprosthetic fracture.</div></div><div><h3>Conclusions</h3><div>BHR patients had higher metal ion levels than ReCap patients at 1-2 and 3-5 y after surgery, though these metal levels are still low and in line with prior studies. Indications for revision differed between patients treated with BHR and ReCap. Surgeons should be aware of these outcomes when counseling patients regarding these metal-on-metal articulations.</div></div>","PeriodicalId":37940,"journal":{"name":"Arthroplasty Today","volume":"30 ","pages":"Article 101555"},"PeriodicalIF":1.5000,"publicationDate":"2024-10-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Blood Metal Ion Levels After Hip Resurfacing: A Comparison of 2 Different Implants\",\"authors\":\"Renee Ren BA,&nbsp;Ryan Cheng BA,&nbsp;Andrew Jordan MS,&nbsp;Jonathan Spaan MS,&nbsp;Rachelle Hornick MPH,&nbsp;Walter L. Taylor IV MPhil,&nbsp;Edwin P. Su MD\",\"doi\":\"10.1016/j.artd.2024.101555\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Background</h3><div>While hip resurfacing arthroplasty has been shown to be an effective prosthetic solution for end-stage osteoarthritis, prior studies have also reported an increasing concern regarding blood metal ion levels following the use of metal-on-metal articulations. The purpose of this study was to compare early and midterm blood metal ion levels to functional outcomes and implant survivorship for patients treated with the Birmingham Hip Resurfacing (BHR) implant system and the ReCap Magnum.</div></div><div><h3>Methods</h3><div>A retrospective review identified 104 patients who underwent 134 hip resurfacing arthroplasties using BHR (n = 67) and ReCap (n = 67) at a single institution between 2006 and 2018. ReCap and BHR patients were matched 1:1 by sex, femoral head and acetabular cup sizes, age, and year of surgery. The primary outcome of interest was cobalt (Co) and chromium (Cr) ion levels.</div></div><div><h3>Results</h3><div>The ReCap cohort had lower median metal ion levels compared to the BHR cohort at 1-2 y (Co: 1.5 vs 1.9 parts per billion [ppb], <em>P</em> = .018; Cr: 1.3 vs 2.8 ppb, <em>P</em> = .008) and 3-5 y (Co: 1.1 vs 1.9 ppb, <em>P</em> = .001; Cr: 1.2 vs 2.2 ppb, <em>P</em> = .003) after surgery. Correlation analysis showed no significant associations between Co and Cr ion levels and pre- and postoperative patient-reported outcomes. Indications for revision differed between groups. Three BHR hips were revised due to adverse reactions to metal debris, whereas 2 ReCap hips required revisions: one for instability and another for periprosthetic fracture.</div></div><div><h3>Conclusions</h3><div>BHR patients had higher metal ion levels than ReCap patients at 1-2 and 3-5 y after surgery, though these metal levels are still low and in line with prior studies. Indications for revision differed between patients treated with BHR and ReCap. Surgeons should be aware of these outcomes when counseling patients regarding these metal-on-metal articulations.</div></div>\",\"PeriodicalId\":37940,\"journal\":{\"name\":\"Arthroplasty Today\",\"volume\":\"30 \",\"pages\":\"Article 101555\"},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2024-10-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Arthroplasty Today\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2352344124002401\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Arthroplasty Today","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2352344124002401","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

摘要

背景虽然髋关节置换术已被证明是治疗终末期骨关节炎的有效假体解决方案,但之前的研究也报告称,使用金属关节后,血液中的金属离子水平越来越令人担忧。本研究的目的是比较使用伯明翰髋关节置换术(BHR)植入系统和 ReCap Magnum 治疗的患者的早期和中期血液金属离子水平、功能预后和植入物存活率。方法回顾性研究确定了 2006 年至 2018 年期间在一家机构使用 BHR(n = 67)和 ReCap(n = 67)进行了 134 例髋关节置换关节置换术的 104 名患者。ReCap和BHR患者按性别、股骨头和髋臼杯尺寸、年龄和手术年份1:1配对。研究的主要结果是钴离子(Co)和铬离子(Cr)水平。结果ReCap队列与BHR队列相比,1-2岁时的金属离子水平中位数较低(Co:1.5 vs 1.9 parts per billion [ppb],P = .018;Cr:1.3 vs 2.8 ppb,P = .018):手术后 1-2 年(Co:1.5 vs 1.9 十亿分之一 [ppb];Cr:1.3 vs 2.8 十亿分之一,P = .008)和 3-5 年(Co:1.1 vs 1.9 十亿分之一,P = .001;Cr:1.2 vs 2.2 十亿分之一,P = .003),与 BHR 队列相比,中位金属离子水平较低。相关性分析表明,Co 和 Cr 离子水平与术前和术后患者报告的结果之间没有明显关联。各组的翻修指征不同。结论BHR患者在术后1-2年和3-5年的金属离子水平高于ReCap患者,但这些金属离子水平仍然较低,与之前的研究结果一致。BHR和ReCap患者的翻修指征不同。外科医生在向患者提供有关这些金属对金属关节的咨询时应注意这些结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Blood Metal Ion Levels After Hip Resurfacing: A Comparison of 2 Different Implants

Background

While hip resurfacing arthroplasty has been shown to be an effective prosthetic solution for end-stage osteoarthritis, prior studies have also reported an increasing concern regarding blood metal ion levels following the use of metal-on-metal articulations. The purpose of this study was to compare early and midterm blood metal ion levels to functional outcomes and implant survivorship for patients treated with the Birmingham Hip Resurfacing (BHR) implant system and the ReCap Magnum.

Methods

A retrospective review identified 104 patients who underwent 134 hip resurfacing arthroplasties using BHR (n = 67) and ReCap (n = 67) at a single institution between 2006 and 2018. ReCap and BHR patients were matched 1:1 by sex, femoral head and acetabular cup sizes, age, and year of surgery. The primary outcome of interest was cobalt (Co) and chromium (Cr) ion levels.

Results

The ReCap cohort had lower median metal ion levels compared to the BHR cohort at 1-2 y (Co: 1.5 vs 1.9 parts per billion [ppb], P = .018; Cr: 1.3 vs 2.8 ppb, P = .008) and 3-5 y (Co: 1.1 vs 1.9 ppb, P = .001; Cr: 1.2 vs 2.2 ppb, P = .003) after surgery. Correlation analysis showed no significant associations between Co and Cr ion levels and pre- and postoperative patient-reported outcomes. Indications for revision differed between groups. Three BHR hips were revised due to adverse reactions to metal debris, whereas 2 ReCap hips required revisions: one for instability and another for periprosthetic fracture.

Conclusions

BHR patients had higher metal ion levels than ReCap patients at 1-2 and 3-5 y after surgery, though these metal levels are still low and in line with prior studies. Indications for revision differed between patients treated with BHR and ReCap. Surgeons should be aware of these outcomes when counseling patients regarding these metal-on-metal articulations.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Arthroplasty Today
Arthroplasty Today Medicine-Surgery
CiteScore
2.90
自引率
0.00%
发文量
258
审稿时长
40 weeks
期刊介绍: Arthroplasty Today is a companion journal to the Journal of Arthroplasty. The journal Arthroplasty Today brings together the clinical and scientific foundations for joint replacement of the hip and knee in an open-access, online format. Arthroplasty Today solicits manuscripts of the highest quality from all areas of scientific endeavor that relate to joint replacement or the treatment of its complications, including those dealing with patient outcomes, economic and policy issues, prosthetic design, biomechanics, biomaterials, and biologic response to arthroplasty. The journal focuses on case reports. It is the purpose of Arthroplasty Today to present material to practicing orthopaedic surgeons that will keep them abreast of developments in the field, prove useful in the care of patients, and aid in understanding the scientific foundation of this subspecialty area of joint replacement. The international members of the Editorial Board provide a worldwide perspective for the journal''s area of interest. Their participation ensures that each issue of Arthroplasty Today provides the reader with timely, peer-reviewed articles of the highest quality.
期刊最新文献
Early Results of a Patient-Specific Total Knee Arthroplasty Implant Cast From a 3D-Printed Mold Evaluation of a Mobile App to Assist Patient Education and Research in Arthroplasty Vancomycin Is Not an Effective Prophylactic Agent Alone and Should Be Combined With Another Agent Are Activity Restrictions Necessary After Total Hip Arthroplasty: A Systematic Review Operatively Managed Transverse or Short Oblique B1 Periprosthetic Fractures Around a Polished Taper-Slip Femoral Stem Are Associated With Reoperation in One Third of Cases: A Retrospective Cohort Study
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1