利用 2 μm 激光吸收光谱法同时测量一氧化碳和二氧化碳以进行燃烧诊断

IF 1 4区 工程技术 Q4 ENGINEERING, ELECTRICAL & ELECTRONIC Microwave and Optical Technology Letters Pub Date : 2024-11-01 DOI:10.1002/mop.70009
Jinyi Li, Keming Wang, Yun Zhou, Zehua Wang, Yue Ji, Zhenhui Du, Xiaotao Yang
{"title":"利用 2 μm 激光吸收光谱法同时测量一氧化碳和二氧化碳以进行燃烧诊断","authors":"Jinyi Li,&nbsp;Keming Wang,&nbsp;Yun Zhou,&nbsp;Zehua Wang,&nbsp;Yue Ji,&nbsp;Zhenhui Du,&nbsp;Xiaotao Yang","doi":"10.1002/mop.70009","DOIUrl":null,"url":null,"abstract":"<p>Carbon monoxide (CO) and carbon dioxide (CO<sub>2</sub>) are products of incomplete combustion and complete combustion, respectively. Time-resolved knowledge of CO and CO<sub>2</sub> exhaust concentrations will aid in improving combustion strategies, control, and efficiency. To achieve online high-precision simultaneous measurement of CO and CO<sub>2</sub>, a tunable diode laser absorption spectroscopy-based sensor is designed and constructed. Two diode lasers with central wavelengths of 2.3 and 2.0 μm are multiplexed in time-division to cover the absorption spectral lines of CO at 4285.00 cm<sup>−1</sup> and CO<sub>2</sub> at 4989.96 cm<sup>−1</sup>, respectively. Wavelength modulation spectroscopy with second harmonic detection normalized by the first harmonic (WMS-2<i>f</i>/1<i>f</i>) is employed. A software lock-in amplifier and inversion algorithm are implemented for data processing and concentration acquisition. The entire measurement system is based on the idea of a virtual instrument and is carried out using a high-speed data acquisition card and a computer. Experimental verification demonstrates that the measurement accuracies of CO and CO<sub>2</sub> were 2.47% and 2.56%, respectively, with a time resolution of 20 ms. Dynamic measurement experiments with an alcohol blast burner validate the feasibility of measuring CO and CO<sub>2</sub> in actual combustion environments. The developed sensor demonstrates the potential for real-time and in situ carbon emission measurement for combustion diagnosis.</p>","PeriodicalId":18562,"journal":{"name":"Microwave and Optical Technology Letters","volume":"66 11","pages":""},"PeriodicalIF":1.0000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Simultaneous measurement of carbon monoxide and carbon dioxide for combustion diagnosis using 2 μm laser absorption spectroscopy\",\"authors\":\"Jinyi Li,&nbsp;Keming Wang,&nbsp;Yun Zhou,&nbsp;Zehua Wang,&nbsp;Yue Ji,&nbsp;Zhenhui Du,&nbsp;Xiaotao Yang\",\"doi\":\"10.1002/mop.70009\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Carbon monoxide (CO) and carbon dioxide (CO<sub>2</sub>) are products of incomplete combustion and complete combustion, respectively. Time-resolved knowledge of CO and CO<sub>2</sub> exhaust concentrations will aid in improving combustion strategies, control, and efficiency. To achieve online high-precision simultaneous measurement of CO and CO<sub>2</sub>, a tunable diode laser absorption spectroscopy-based sensor is designed and constructed. Two diode lasers with central wavelengths of 2.3 and 2.0 μm are multiplexed in time-division to cover the absorption spectral lines of CO at 4285.00 cm<sup>−1</sup> and CO<sub>2</sub> at 4989.96 cm<sup>−1</sup>, respectively. Wavelength modulation spectroscopy with second harmonic detection normalized by the first harmonic (WMS-2<i>f</i>/1<i>f</i>) is employed. A software lock-in amplifier and inversion algorithm are implemented for data processing and concentration acquisition. The entire measurement system is based on the idea of a virtual instrument and is carried out using a high-speed data acquisition card and a computer. Experimental verification demonstrates that the measurement accuracies of CO and CO<sub>2</sub> were 2.47% and 2.56%, respectively, with a time resolution of 20 ms. Dynamic measurement experiments with an alcohol blast burner validate the feasibility of measuring CO and CO<sub>2</sub> in actual combustion environments. The developed sensor demonstrates the potential for real-time and in situ carbon emission measurement for combustion diagnosis.</p>\",\"PeriodicalId\":18562,\"journal\":{\"name\":\"Microwave and Optical Technology Letters\",\"volume\":\"66 11\",\"pages\":\"\"},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2024-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Microwave and Optical Technology Letters\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/mop.70009\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Microwave and Optical Technology Letters","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/mop.70009","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

摘要

一氧化碳(CO)和二氧化碳(CO2)分别是不完全燃烧和完全燃烧的产物。对一氧化碳和二氧化碳废气浓度的时间分辨知识将有助于改进燃烧策略、控制和效率。为实现 CO 和 CO2 的在线高精度同步测量,设计并构建了基于可调谐二极管激光吸收光谱的传感器。两个中心波长分别为 2.3 和 2.0 μm 的二极管激光器以时分方式复用,分别覆盖 4285.00 cm-1 处的 CO 和 4989.96 cm-1 处的 CO2 吸收光谱线。采用波长调制光谱法,二次谐波检测按一次谐波归一化(WMS-2f/1f)。数据处理和浓度采集采用软件锁相放大器和反演算法。整个测量系统基于虚拟仪器的理念,通过高速数据采集卡和计算机来实现。实验验证表明,在时间分辨率为 20 毫秒的情况下,一氧化碳和二氧化碳的测量精度分别为 2.47% 和 2.56%。酒精鼓风燃烧器的动态测量实验验证了在实际燃烧环境中测量一氧化碳和二氧化碳的可行性。所开发的传感器证明了用于燃烧诊断的实时和现场碳排放测量的潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Simultaneous measurement of carbon monoxide and carbon dioxide for combustion diagnosis using 2 μm laser absorption spectroscopy

Carbon monoxide (CO) and carbon dioxide (CO2) are products of incomplete combustion and complete combustion, respectively. Time-resolved knowledge of CO and CO2 exhaust concentrations will aid in improving combustion strategies, control, and efficiency. To achieve online high-precision simultaneous measurement of CO and CO2, a tunable diode laser absorption spectroscopy-based sensor is designed and constructed. Two diode lasers with central wavelengths of 2.3 and 2.0 μm are multiplexed in time-division to cover the absorption spectral lines of CO at 4285.00 cm−1 and CO2 at 4989.96 cm−1, respectively. Wavelength modulation spectroscopy with second harmonic detection normalized by the first harmonic (WMS-2f/1f) is employed. A software lock-in amplifier and inversion algorithm are implemented for data processing and concentration acquisition. The entire measurement system is based on the idea of a virtual instrument and is carried out using a high-speed data acquisition card and a computer. Experimental verification demonstrates that the measurement accuracies of CO and CO2 were 2.47% and 2.56%, respectively, with a time resolution of 20 ms. Dynamic measurement experiments with an alcohol blast burner validate the feasibility of measuring CO and CO2 in actual combustion environments. The developed sensor demonstrates the potential for real-time and in situ carbon emission measurement for combustion diagnosis.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Microwave and Optical Technology Letters
Microwave and Optical Technology Letters 工程技术-工程:电子与电气
CiteScore
3.40
自引率
20.00%
发文量
371
审稿时长
4.3 months
期刊介绍: Microwave and Optical Technology Letters provides quick publication (3 to 6 month turnaround) of the most recent findings and achievements in high frequency technology, from RF to optical spectrum. The journal publishes original short papers and letters on theoretical, applied, and system results in the following areas. - RF, Microwave, and Millimeter Waves - Antennas and Propagation - Submillimeter-Wave and Infrared Technology - Optical Engineering All papers are subject to peer review before publication
期刊最新文献
A 26.5–29.5-GHz Current-Reused Low Noise Amplifier With Optimized Gate Bias and Flat-Gain Matching Techniques for 5G Communication A Circularly Polarized Filtering Patch Antenna Based on Parasitic Patches With Slots Design of a Bandpass Continuous Class-F Filtering Power Amplifier Based on a Terminated Coupled Lines Structure SIW Broadband Circularly Polarized High-Gain Low-Profile Magneto-Electric Dipole Antenna Array A 26-GHz Low Noise Amplifier With 16-dB Minimum Noise Figure in 015-μm GaN-on-SiC Process
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1