评估未成熟恒牙正交根充材料的微渗漏:体外研究

IF 3 Q3 MATERIALS SCIENCE, BIOMATERIALS International Journal of Biomaterials Pub Date : 2024-10-29 eCollection Date: 2024-01-01 DOI:10.1155/2024/8867854
Upma Das, Vanita Gautam, Snigdha Shubham, Shristi Raut
{"title":"评估未成熟恒牙正交根充材料的微渗漏:体外研究","authors":"Upma Das, Vanita Gautam, Snigdha Shubham, Shristi Raut","doi":"10.1155/2024/8867854","DOIUrl":null,"url":null,"abstract":"<p><p><b>Introduction:</b> The absence of a barrier in an open root apex makes endodontic treatment challenging as root-filling material can easily reach the surrounding tissue. The aim of the study was to compare the apical microleakage associated with mineral trioxide aggregate (MTA), biodentine, custom-made gutta-percha with MTA plus and custom-made gutta-percha with Adseal in immature permanent teeth by dye penetration method. <b>Methods:</b> Apical 2 mm of 60 single-rooted mandibular premolar teeth was resected to create divergent open apices and 10 teeth each were filled with Biodentine plug, MTA plug, custom-made gutta-percha with MTA plus sealer and custom-made gutta-percha with Adseal sealer. Ten teeth each acted as positive and negative controls. All the samples were stored at 37°C at 100% humidity for 5 weeks and then immersed in 2% Rhodamine B dye for 24 h. Transverse sectioning was done apically at 1 mm and 3 mm to evaluate dye penetration under a fluorescence microscope using ImageJ software. <b>Results:</b> There was a significantly greater microleakage at 1 mm cross section compared to 3 mm (<i>p</i> < 0.0001). At 1 mm cross section, the apical microleakage was the highest for the MTA plug with a mean leakage percentage of 48.08 ± 16.38, a mean depth of leakage of 0.46 ± 0.10 mm and a mean area of leakage of 1.35 ± 0.74 mm<sup>2</sup>, compared to other groups, and the difference was statistically significant. However, at a 3 mm cross section, MTA plus sealer with gutta-percha demonstrated the highest mean leakage percentage (25.01 ± 7.77) compared to other groups and the difference was statistically significant (<i>p</i> = 0.03). <b>Conclusion:</b> It can be concluded that the 3-mm-thick apical plug provided better sealing of the open apex compared to the 1 mm apical plug and there was no significant difference in microleakage among the Biodentine plug, MTA plug and Adseal sealer with gutta-percha plug at 3 mm cross section.</p>","PeriodicalId":13704,"journal":{"name":"International Journal of Biomaterials","volume":"2024 ","pages":"8867854"},"PeriodicalIF":3.0000,"publicationDate":"2024-10-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11537741/pdf/","citationCount":"0","resultStr":"{\"title\":\"Evaluation of Microleakage of Orthograde Root-Filling Materials in Immature Permanent Teeth: An In Vitro Study.\",\"authors\":\"Upma Das, Vanita Gautam, Snigdha Shubham, Shristi Raut\",\"doi\":\"10.1155/2024/8867854\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b>Introduction:</b> The absence of a barrier in an open root apex makes endodontic treatment challenging as root-filling material can easily reach the surrounding tissue. The aim of the study was to compare the apical microleakage associated with mineral trioxide aggregate (MTA), biodentine, custom-made gutta-percha with MTA plus and custom-made gutta-percha with Adseal in immature permanent teeth by dye penetration method. <b>Methods:</b> Apical 2 mm of 60 single-rooted mandibular premolar teeth was resected to create divergent open apices and 10 teeth each were filled with Biodentine plug, MTA plug, custom-made gutta-percha with MTA plus sealer and custom-made gutta-percha with Adseal sealer. Ten teeth each acted as positive and negative controls. All the samples were stored at 37°C at 100% humidity for 5 weeks and then immersed in 2% Rhodamine B dye for 24 h. Transverse sectioning was done apically at 1 mm and 3 mm to evaluate dye penetration under a fluorescence microscope using ImageJ software. <b>Results:</b> There was a significantly greater microleakage at 1 mm cross section compared to 3 mm (<i>p</i> < 0.0001). At 1 mm cross section, the apical microleakage was the highest for the MTA plug with a mean leakage percentage of 48.08 ± 16.38, a mean depth of leakage of 0.46 ± 0.10 mm and a mean area of leakage of 1.35 ± 0.74 mm<sup>2</sup>, compared to other groups, and the difference was statistically significant. However, at a 3 mm cross section, MTA plus sealer with gutta-percha demonstrated the highest mean leakage percentage (25.01 ± 7.77) compared to other groups and the difference was statistically significant (<i>p</i> = 0.03). <b>Conclusion:</b> It can be concluded that the 3-mm-thick apical plug provided better sealing of the open apex compared to the 1 mm apical plug and there was no significant difference in microleakage among the Biodentine plug, MTA plug and Adseal sealer with gutta-percha plug at 3 mm cross section.</p>\",\"PeriodicalId\":13704,\"journal\":{\"name\":\"International Journal of Biomaterials\",\"volume\":\"2024 \",\"pages\":\"8867854\"},\"PeriodicalIF\":3.0000,\"publicationDate\":\"2024-10-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11537741/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Biomaterials\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1155/2024/8867854\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q3\",\"JCRName\":\"MATERIALS SCIENCE, BIOMATERIALS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Biomaterials","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2024/8867854","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0

摘要

导言:开放的根尖没有屏障,使得根管治疗具有挑战性,因为根充材料很容易到达周围组织。本研究的目的是通过染料渗透法,比较未成熟恒牙中与三氧化二铝矿物质骨料(MTA)、生物碱、定制的古塔波瓷加 MTA 和定制的古塔波瓷加 Adseal 相关的根尖微渗漏情况。方法:切除 60 颗单根下颌前磨牙的根尖 2 毫米,形成分叉开放的根尖,并分别用 Biodentine 栓塞、MTA 栓塞、定制的带有 MTA plus 封闭剂的古塔波查和定制的带有 Adseal 封闭剂的古塔波查填充各 10 颗牙齿。阳性和阴性对照组各 10 颗牙齿。使用 ImageJ 软件在荧光显微镜下评估染料的渗透情况。结果:与 3 毫米横切面相比,1 毫米横切面的微渗漏率明显更高(p < 0.0001)。与其他组相比,在 1 毫米横截面上,MTA 插塞的顶端微渗漏最高,平均渗漏百分比为 48.08 ± 16.38,平均渗漏深度为 0.46 ± 0.10 毫米,平均渗漏面积为 1.35 ± 0.74 平方毫米,差异具有统计学意义。然而,在 3 毫米的横截面上,与其他组别相比,MTA 加带古塔漆的封闭剂的平均渗漏百分比(25.01 ± 7.77)最高,差异有统计学意义(p = 0.03)。结论可以得出结论,与 1 毫米的根尖塞相比,3 毫米厚的根尖塞能更好地密封开放的根尖,而且在 3 毫米横截面上,Biodentine 塞、MTA 塞和 Adseal 密封剂加古塔碱塞在微渗漏方面没有显著差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Evaluation of Microleakage of Orthograde Root-Filling Materials in Immature Permanent Teeth: An In Vitro Study.

Introduction: The absence of a barrier in an open root apex makes endodontic treatment challenging as root-filling material can easily reach the surrounding tissue. The aim of the study was to compare the apical microleakage associated with mineral trioxide aggregate (MTA), biodentine, custom-made gutta-percha with MTA plus and custom-made gutta-percha with Adseal in immature permanent teeth by dye penetration method. Methods: Apical 2 mm of 60 single-rooted mandibular premolar teeth was resected to create divergent open apices and 10 teeth each were filled with Biodentine plug, MTA plug, custom-made gutta-percha with MTA plus sealer and custom-made gutta-percha with Adseal sealer. Ten teeth each acted as positive and negative controls. All the samples were stored at 37°C at 100% humidity for 5 weeks and then immersed in 2% Rhodamine B dye for 24 h. Transverse sectioning was done apically at 1 mm and 3 mm to evaluate dye penetration under a fluorescence microscope using ImageJ software. Results: There was a significantly greater microleakage at 1 mm cross section compared to 3 mm (p < 0.0001). At 1 mm cross section, the apical microleakage was the highest for the MTA plug with a mean leakage percentage of 48.08 ± 16.38, a mean depth of leakage of 0.46 ± 0.10 mm and a mean area of leakage of 1.35 ± 0.74 mm2, compared to other groups, and the difference was statistically significant. However, at a 3 mm cross section, MTA plus sealer with gutta-percha demonstrated the highest mean leakage percentage (25.01 ± 7.77) compared to other groups and the difference was statistically significant (p = 0.03). Conclusion: It can be concluded that the 3-mm-thick apical plug provided better sealing of the open apex compared to the 1 mm apical plug and there was no significant difference in microleakage among the Biodentine plug, MTA plug and Adseal sealer with gutta-percha plug at 3 mm cross section.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
International Journal of Biomaterials
International Journal of Biomaterials MATERIALS SCIENCE, BIOMATERIALS-
CiteScore
4.30
自引率
3.20%
发文量
50
审稿时长
21 weeks
期刊最新文献
Synthesis of Calcium Phosphate by Microwave Hydrothermal Method: Physicochemical and Morphological Characterization. Isolation of B Cells Using Silane-Coated Magnetic Nanoparticles. Evaluation of Microleakage of Orthograde Root-Filling Materials in Immature Permanent Teeth: An In Vitro Study. Production of Composite Briquette Fuel from Brewery Wastewater Sludge and Spent Grains. Unveiling SmearOFF Efficacy in Smear Layer Removal through Ultrasonic Activation Examined by Scanning Electron Microscopy.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1