成年患者使用矫治器进行磨牙远端矫治后上呼吸道流体力学的变化。

IF 3.1 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE Clinical Oral Investigations Pub Date : 2024-11-07 DOI:10.1007/s00784-024-06029-y
Yi Zhao, Yuyu Ge, Wenfeng Chen, Shuai Chen, Zhiqiang Wang
{"title":"成年患者使用矫治器进行磨牙远端矫治后上呼吸道流体力学的变化。","authors":"Yi Zhao, Yuyu Ge, Wenfeng Chen, Shuai Chen, Zhiqiang Wang","doi":"10.1007/s00784-024-06029-y","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>The aim of this study was to evaluate the changes of upper airway ventilation function after molar distalization with aligners in adult patients by computational fluid dynamic simulation.</p><p><strong>Materials and methods: </strong>A total of 15 subjects were included (3 males and 12 females, with an average age of 20.00 ± 0.50 years) who required en masse distal movement of the whole dentition using Invisalign aligners. The software Mimics 19.0 was used to reconstruct the upper airway based on their CBCT images and measure the minimum cross-sectional area and volume before and after treatment. Then the upper airway flow during inspirations was simulated and evaluated using Ansys software. At last, the morphologic and hydrodynamic parameters before and after treatment were compared using paired T-test.</p><p><strong>Results: </strong>For morphological evaluation, the volume changes of velopharynx, glossopharynx and hypopharynx volume revealed no statistically significance after treatment compared to the data before treatment, the minimum cross section of upper airway decreased significantly. For hydrodynamics parameters, the minimum pressure, maximum shear force, velopharynx and glossopharynx pressure drop increased 50.2 Pa, 0.66 Pa, 5.78 Pa and 5.32 Pa respectively. At last, the correlation analysis between CFD data and MCA is of no statistical significance.</p><p><strong>Conclusion: </strong>Non-extraction molar distalization using invisible aligners and mini-screws may lead to adverse changes in upper airway fluid dynamics, potentially increasing the risk of pharyngeal collapse.</p><p><strong>Clinical relevance: </strong>The combination of invisible appliances with anchorage implants for the distalization of maxillary and/or mandibular teeth has emerged as a prevalent orthodontic technique. Clinicians should consider the potential impact on respiratory function when contemplating such treatment for patients with pre-existing respiratory conditions or those at a higher risk of ventilation issues.</p>","PeriodicalId":10461,"journal":{"name":"Clinical Oral Investigations","volume":"28 12","pages":"630"},"PeriodicalIF":3.1000,"publicationDate":"2024-11-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Upper airway hydrodynamics changes after molar distalization with aligners in adult patients.\",\"authors\":\"Yi Zhao, Yuyu Ge, Wenfeng Chen, Shuai Chen, Zhiqiang Wang\",\"doi\":\"10.1007/s00784-024-06029-y\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>The aim of this study was to evaluate the changes of upper airway ventilation function after molar distalization with aligners in adult patients by computational fluid dynamic simulation.</p><p><strong>Materials and methods: </strong>A total of 15 subjects were included (3 males and 12 females, with an average age of 20.00 ± 0.50 years) who required en masse distal movement of the whole dentition using Invisalign aligners. The software Mimics 19.0 was used to reconstruct the upper airway based on their CBCT images and measure the minimum cross-sectional area and volume before and after treatment. Then the upper airway flow during inspirations was simulated and evaluated using Ansys software. At last, the morphologic and hydrodynamic parameters before and after treatment were compared using paired T-test.</p><p><strong>Results: </strong>For morphological evaluation, the volume changes of velopharynx, glossopharynx and hypopharynx volume revealed no statistically significance after treatment compared to the data before treatment, the minimum cross section of upper airway decreased significantly. For hydrodynamics parameters, the minimum pressure, maximum shear force, velopharynx and glossopharynx pressure drop increased 50.2 Pa, 0.66 Pa, 5.78 Pa and 5.32 Pa respectively. At last, the correlation analysis between CFD data and MCA is of no statistical significance.</p><p><strong>Conclusion: </strong>Non-extraction molar distalization using invisible aligners and mini-screws may lead to adverse changes in upper airway fluid dynamics, potentially increasing the risk of pharyngeal collapse.</p><p><strong>Clinical relevance: </strong>The combination of invisible appliances with anchorage implants for the distalization of maxillary and/or mandibular teeth has emerged as a prevalent orthodontic technique. Clinicians should consider the potential impact on respiratory function when contemplating such treatment for patients with pre-existing respiratory conditions or those at a higher risk of ventilation issues.</p>\",\"PeriodicalId\":10461,\"journal\":{\"name\":\"Clinical Oral Investigations\",\"volume\":\"28 12\",\"pages\":\"630\"},\"PeriodicalIF\":3.1000,\"publicationDate\":\"2024-11-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical Oral Investigations\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s00784-024-06029-y\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Oral Investigations","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00784-024-06029-y","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

研究目的本研究旨在通过计算流体动力学模拟评估成年患者使用矫治器进行磨牙远端移动后上呼吸道通气功能的变化:共有 15 名受试者(3 男 12 女,平均年龄为 20.00 ± 0.50 岁)需要使用隐适美矫正器对整个牙齿进行整体远端移动。使用 Mimics 19.0 软件根据 CBCT 图像重建上气道,并测量治疗前后的最小横截面积和体积。然后使用 Ansys 软件模拟和评估了吸气时上气道的流动情况。最后,使用配对 T 检验比较治疗前后的形态学和流体力学参数:结果:在形态学评价方面,治疗后咽口、舌咽和下咽的体积变化与治疗前相比无统计学意义,但上气道最小横截面明显缩小。在流体力学参数方面,最小压力、最大剪切力、会厌和舌咽压力降分别增加了 50.2 Pa、0.66 Pa、5.78 Pa 和 5.32 Pa。最后,CFD 数据与 MCA 之间的相关性分析没有统计学意义:临床意义:将隐形矫治器与固定种植体结合用于上颌和/或下颌牙齿的远端矫治已成为一种流行的正畸技术。临床医生在考虑对已有呼吸系统疾病或通气问题风险较高的患者进行此类治疗时,应考虑到对呼吸功能的潜在影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Upper airway hydrodynamics changes after molar distalization with aligners in adult patients.

Objectives: The aim of this study was to evaluate the changes of upper airway ventilation function after molar distalization with aligners in adult patients by computational fluid dynamic simulation.

Materials and methods: A total of 15 subjects were included (3 males and 12 females, with an average age of 20.00 ± 0.50 years) who required en masse distal movement of the whole dentition using Invisalign aligners. The software Mimics 19.0 was used to reconstruct the upper airway based on their CBCT images and measure the minimum cross-sectional area and volume before and after treatment. Then the upper airway flow during inspirations was simulated and evaluated using Ansys software. At last, the morphologic and hydrodynamic parameters before and after treatment were compared using paired T-test.

Results: For morphological evaluation, the volume changes of velopharynx, glossopharynx and hypopharynx volume revealed no statistically significance after treatment compared to the data before treatment, the minimum cross section of upper airway decreased significantly. For hydrodynamics parameters, the minimum pressure, maximum shear force, velopharynx and glossopharynx pressure drop increased 50.2 Pa, 0.66 Pa, 5.78 Pa and 5.32 Pa respectively. At last, the correlation analysis between CFD data and MCA is of no statistical significance.

Conclusion: Non-extraction molar distalization using invisible aligners and mini-screws may lead to adverse changes in upper airway fluid dynamics, potentially increasing the risk of pharyngeal collapse.

Clinical relevance: The combination of invisible appliances with anchorage implants for the distalization of maxillary and/or mandibular teeth has emerged as a prevalent orthodontic technique. Clinicians should consider the potential impact on respiratory function when contemplating such treatment for patients with pre-existing respiratory conditions or those at a higher risk of ventilation issues.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Clinical Oral Investigations
Clinical Oral Investigations 医学-牙科与口腔外科
CiteScore
6.30
自引率
5.90%
发文量
484
审稿时长
3 months
期刊介绍: The journal Clinical Oral Investigations is a multidisciplinary, international forum for publication of research from all fields of oral medicine. The journal publishes original scientific articles and invited reviews which provide up-to-date results of basic and clinical studies in oral and maxillofacial science and medicine. The aim is to clarify the relevance of new results to modern practice, for an international readership. Coverage includes maxillofacial and oral surgery, prosthetics and restorative dentistry, operative dentistry, endodontics, periodontology, orthodontics, dental materials science, clinical trials, epidemiology, pedodontics, oral implant, preventive dentistiry, oral pathology, oral basic sciences and more.
期刊最新文献
A technical note on the Kamranmeter; a manually operated device for measuring salivary spinnbarkeit. The clinical and microbiological efficacy of a zinc-citrate/hydroxyapatite/potassium-citrate containing toothpaste: a double-blind randomized controlled clinical trial. Fluorescence and color adjustment potentials of paste-type and flowable resin composites in cervical restorations. AI-driven segmentation of the pulp cavity system in mandibular molars on CBCT images using convolutional neural networks. Automatic detection and proximity quantification of inferior alveolar nerve and mandibular third molar on cone-beam computed tomography.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1