在儿童急性淋巴细胞白血病中采用基于平板阅读器的indooxine和Nessler方案监测L-天冬酰胺酶血清活性。

IF 2.5 Q3 BIOCHEMICAL RESEARCH METHODS Biology Methods and Protocols Pub Date : 2024-06-13 eCollection Date: 2024-01-01 DOI:10.1093/biomethods/bpae042
Bozhidar Vergov, Yordan Sbirkov, Danail Minchev, Tatyana Todorova, Alexandra Baldzhieva, Hasan Burnusuzov, Мariya I Spasova, Victoria Sarafian
{"title":"在儿童急性淋巴细胞白血病中采用基于平板阅读器的indooxine和Nessler方案监测L-天冬酰胺酶血清活性。","authors":"Bozhidar Vergov, Yordan Sbirkov, Danail Minchev, Tatyana Todorova, Alexandra Baldzhieva, Hasan Burnusuzov, Мariya I Spasova, Victoria Sarafian","doi":"10.1093/biomethods/bpae042","DOIUrl":null,"url":null,"abstract":"<p><p>Monitoring the blood serum activity of L-asparaginase in children with acute lymphoblastic leukaemia (ALL) has been highly recommended to detect enzyme inactivation that can cause relapse and to avoid unwanted toxicity. Nevertheless, perhaps at least partially due to the lack of clinically approved commercially available kits or standardized and independently reproduced and validated in-house protocols, laboratory assay-based determination of the optimal doses of L-asparaginase is not carried out routinely. In this study, we adapted previously published protocols for two plate reader-based colorimetric methods, indooxine and Nessler, to measure asparaginase activity. Mock samples with dilutions of the enzyme for initial optimization steps, and patient samples were used as a proof of principle and to compare the two protocols. For the first time the indooxine and the Nessler methods are adapted for a plate reader and L-asparaginase serum activity levels are compared by both protocols. Passing-Bablok and Bland-Altman's statistical analyses found very little difference, strong correlation (<i>r</i> = 0.852), and bias of only 6% between the data from the two methods when used for fresh patient samples. Furthermore, we demonstrate that the Nessler method could also be applied for frozen sera as the results, compared to fresh samples, showed little difference, strong correlation (<i>r</i> = 0.817), and small bias (9%). We successfully adapted and validated two methods for measuring L-asparaginase activity in cALL and provided the most detailed description to date on how to reproduce and implement them in other clinical laboratories.</p>","PeriodicalId":36528,"journal":{"name":"Biology Methods and Protocols","volume":"9 1","pages":"bpae042"},"PeriodicalIF":2.5000,"publicationDate":"2024-06-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11557903/pdf/","citationCount":"0","resultStr":"{\"title\":\"Implementation of plate reader-based indooxine and Nessler protocols for monitoring L-asparaginase serum activity in childhood acute lymphoblastic leukaemia.\",\"authors\":\"Bozhidar Vergov, Yordan Sbirkov, Danail Minchev, Tatyana Todorova, Alexandra Baldzhieva, Hasan Burnusuzov, Мariya I Spasova, Victoria Sarafian\",\"doi\":\"10.1093/biomethods/bpae042\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Monitoring the blood serum activity of L-asparaginase in children with acute lymphoblastic leukaemia (ALL) has been highly recommended to detect enzyme inactivation that can cause relapse and to avoid unwanted toxicity. Nevertheless, perhaps at least partially due to the lack of clinically approved commercially available kits or standardized and independently reproduced and validated in-house protocols, laboratory assay-based determination of the optimal doses of L-asparaginase is not carried out routinely. In this study, we adapted previously published protocols for two plate reader-based colorimetric methods, indooxine and Nessler, to measure asparaginase activity. Mock samples with dilutions of the enzyme for initial optimization steps, and patient samples were used as a proof of principle and to compare the two protocols. For the first time the indooxine and the Nessler methods are adapted for a plate reader and L-asparaginase serum activity levels are compared by both protocols. Passing-Bablok and Bland-Altman's statistical analyses found very little difference, strong correlation (<i>r</i> = 0.852), and bias of only 6% between the data from the two methods when used for fresh patient samples. Furthermore, we demonstrate that the Nessler method could also be applied for frozen sera as the results, compared to fresh samples, showed little difference, strong correlation (<i>r</i> = 0.817), and small bias (9%). We successfully adapted and validated two methods for measuring L-asparaginase activity in cALL and provided the most detailed description to date on how to reproduce and implement them in other clinical laboratories.</p>\",\"PeriodicalId\":36528,\"journal\":{\"name\":\"Biology Methods and Protocols\",\"volume\":\"9 1\",\"pages\":\"bpae042\"},\"PeriodicalIF\":2.5000,\"publicationDate\":\"2024-06-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11557903/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biology Methods and Protocols\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1093/biomethods/bpae042\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q3\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biology Methods and Protocols","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/biomethods/bpae042","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

摘要

人们强烈建议监测急性淋巴细胞白血病(ALL)患儿血清中 L-天冬酰胺酶的活性,以检测可能导致复发的酶失活,并避免不必要的毒性。然而,也许至少部分是由于缺乏临床认可的市售试剂盒或标准化、独立复制和验证的内部方案,实验室测定 L-天冬酰胺酶最佳剂量的工作并未常规化。在本研究中,我们改编了之前发表的两种基于平板阅读器的比色法(indooxine 和 Nessler),用于测量天冬酰胺酶的活性。我们用稀释了酶的模拟样本和病人样本作为初始优化步骤,并对两种方法进行了原理验证和比较。这是首次将吲哚辛法和奈斯勒法应用于平板阅读器,并通过两种方法比较 L-天冬酰胺酶的血清活性水平。Passing-Bablok 和 Bland-Altman 统计分析发现,在用于新鲜患者样本时,两种方法的数据差异很小,相关性很强(r = 0.852),偏差仅为 6%。此外,我们还证明奈斯勒方法也可用于冷冻血清,因为与新鲜样本相比,结果显示差异很小,相关性很强(r = 0.817),偏差很小(9%)。我们成功地调整并验证了两种测量 cALL 中 L-天冬酰胺酶活性的方法,并就如何在其他临床实验室中复制和实施这两种方法提供了迄今为止最详细的说明。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Implementation of plate reader-based indooxine and Nessler protocols for monitoring L-asparaginase serum activity in childhood acute lymphoblastic leukaemia.

Monitoring the blood serum activity of L-asparaginase in children with acute lymphoblastic leukaemia (ALL) has been highly recommended to detect enzyme inactivation that can cause relapse and to avoid unwanted toxicity. Nevertheless, perhaps at least partially due to the lack of clinically approved commercially available kits or standardized and independently reproduced and validated in-house protocols, laboratory assay-based determination of the optimal doses of L-asparaginase is not carried out routinely. In this study, we adapted previously published protocols for two plate reader-based colorimetric methods, indooxine and Nessler, to measure asparaginase activity. Mock samples with dilutions of the enzyme for initial optimization steps, and patient samples were used as a proof of principle and to compare the two protocols. For the first time the indooxine and the Nessler methods are adapted for a plate reader and L-asparaginase serum activity levels are compared by both protocols. Passing-Bablok and Bland-Altman's statistical analyses found very little difference, strong correlation (r = 0.852), and bias of only 6% between the data from the two methods when used for fresh patient samples. Furthermore, we demonstrate that the Nessler method could also be applied for frozen sera as the results, compared to fresh samples, showed little difference, strong correlation (r = 0.817), and small bias (9%). We successfully adapted and validated two methods for measuring L-asparaginase activity in cALL and provided the most detailed description to date on how to reproduce and implement them in other clinical laboratories.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Biology Methods and Protocols
Biology Methods and Protocols Agricultural and Biological Sciences-Agricultural and Biological Sciences (all)
CiteScore
3.80
自引率
2.80%
发文量
28
审稿时长
19 weeks
期刊最新文献
Efficient protocol for isolating human fibroblast from primary skin cell cultures: application to keloid, hypertrophic scar, and normal skin biopsies. Modified throughput ninhydrin method for the qualitative assessment of dietary protein absorption in pig plasma. Optimizing Western blotting immunodetection: Streamlining antibody cocktails for reduced protocol time and enhanced multiplexing applications. Live cell fluorescence microscopy-an end-to-end workflow for high-throughput image and data analysis. A reproducible method to study traumatic injury-induced zebrafish brain regeneration.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1