基于尺寸排除效应的超低堵塞电化学摩卡印迹传感器,用于高选择性检测五氯苯酚

IF 8 1区 化学 Q1 CHEMISTRY, ANALYTICAL Sensors and Actuators B: Chemical Pub Date : 2024-11-19 DOI:10.1016/j.snb.2024.136974
Chen Cheng, Xiaoyu Zhu, Xingao Qin, Jinzhu Zhang, Meng Liu, Ying Wang
{"title":"基于尺寸排除效应的超低堵塞电化学摩卡印迹传感器,用于高选择性检测五氯苯酚","authors":"Chen Cheng, Xiaoyu Zhu, Xingao Qin, Jinzhu Zhang, Meng Liu, Ying Wang","doi":"10.1016/j.snb.2024.136974","DOIUrl":null,"url":null,"abstract":"Pentachlorophenol (PCP) is considered as a highly toxic pollutant in water environment. However, detecting low concentrations of PCP precisely hindered by various interferences is still a tough challenge. In this study, an antifouling electrochemical molecularly imprinted (E-MIP) sensor harnessing the size exclusion effect was specifically designed for highly selective detection of PCP in water. The distinctive interaction between the size-selective poly-hydroxyproline helical peptide (PHHP) and poly(<em>o</em>-phenylenediamine) (p(o-PD)) molecularly imprinted films, strongly reduced non-specific adsorption. In the face of high concentrations of organic matters and ions, the reported sensor exhibited robust antifouling capabilities that it preserved 90 % of the initial signal. In addition, the limit of detection (LOD) reached an exceptionally low level of 1.13 nM (S/N = 3), spanning a wide linear range from 1 nM to 10 μM, and the sensor showed high selectivity with an impressive imprinted factor of 12.01 for PCP. Meanwhile, it owned great repeatability and reproducibility, long-term stability for PCP detection within 25 days, and decent reusability (retaining 92.33 % of its senor performance after 5 cycles), which ensured its excellent feasibility for determination of PCP in complex water samples with co-existing interferences due to acceptable recoveries. The development of this strategy provides an innovative platform for PCP quantification in real water samples, underscoring its potential as a key tool in managing PCP at relevant sites.","PeriodicalId":425,"journal":{"name":"Sensors and Actuators B: Chemical","volume":"99 1","pages":""},"PeriodicalIF":8.0000,"publicationDate":"2024-11-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"An ultra-low fouling electrochemical mocularly imprinted sensor based on size exclusion effect for highly selective pentachlorophenol detection\",\"authors\":\"Chen Cheng, Xiaoyu Zhu, Xingao Qin, Jinzhu Zhang, Meng Liu, Ying Wang\",\"doi\":\"10.1016/j.snb.2024.136974\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Pentachlorophenol (PCP) is considered as a highly toxic pollutant in water environment. However, detecting low concentrations of PCP precisely hindered by various interferences is still a tough challenge. In this study, an antifouling electrochemical molecularly imprinted (E-MIP) sensor harnessing the size exclusion effect was specifically designed for highly selective detection of PCP in water. The distinctive interaction between the size-selective poly-hydroxyproline helical peptide (PHHP) and poly(<em>o</em>-phenylenediamine) (p(o-PD)) molecularly imprinted films, strongly reduced non-specific adsorption. In the face of high concentrations of organic matters and ions, the reported sensor exhibited robust antifouling capabilities that it preserved 90 % of the initial signal. In addition, the limit of detection (LOD) reached an exceptionally low level of 1.13 nM (S/N = 3), spanning a wide linear range from 1 nM to 10 μM, and the sensor showed high selectivity with an impressive imprinted factor of 12.01 for PCP. Meanwhile, it owned great repeatability and reproducibility, long-term stability for PCP detection within 25 days, and decent reusability (retaining 92.33 % of its senor performance after 5 cycles), which ensured its excellent feasibility for determination of PCP in complex water samples with co-existing interferences due to acceptable recoveries. The development of this strategy provides an innovative platform for PCP quantification in real water samples, underscoring its potential as a key tool in managing PCP at relevant sites.\",\"PeriodicalId\":425,\"journal\":{\"name\":\"Sensors and Actuators B: Chemical\",\"volume\":\"99 1\",\"pages\":\"\"},\"PeriodicalIF\":8.0000,\"publicationDate\":\"2024-11-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Sensors and Actuators B: Chemical\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.1016/j.snb.2024.136974\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sensors and Actuators B: Chemical","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1016/j.snb.2024.136974","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

五氯苯酚(PCP)被认为是水环境中的剧毒污染物。然而,在各种干扰的阻碍下,精确检测低浓度的五氯苯酚仍然是一项艰巨的挑战。本研究专门设计了一种利用尺寸排阻效应的防污电化学分子印迹(E-MIP)传感器,用于高选择性检测水中的五氯苯酚。尺寸选择性聚羟脯氨酸螺旋肽(PHHP)与聚邻苯二胺(p(o-PD))分子印迹薄膜之间的独特相互作用大大减少了非特异性吸附。面对高浓度的有机物和离子,所报告的传感器表现出强大的防污能力,能保持 90% 的初始信号。此外,该传感器的检测限(LOD)达到了 1.13 nM 的超低水平(S/N = 3),线性范围从 1 nM 到 10 μM。同时,该传感器还具有极高的重复性和再现性、25 天内检测五氯苯酚的长期稳定性以及良好的可重复使用性(5 次循环后仍能保持 92.33% 的传感器性能),这确保了其在具有共存干扰的复杂水样中检测五氯苯酚的极佳可行性,因为其回收率是可接受的。该策略的开发为实际水样中的五氯苯酚定量提供了一个创新平台,凸显了其作为相关场所管理五氯苯酚的关键工具的潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
An ultra-low fouling electrochemical mocularly imprinted sensor based on size exclusion effect for highly selective pentachlorophenol detection
Pentachlorophenol (PCP) is considered as a highly toxic pollutant in water environment. However, detecting low concentrations of PCP precisely hindered by various interferences is still a tough challenge. In this study, an antifouling electrochemical molecularly imprinted (E-MIP) sensor harnessing the size exclusion effect was specifically designed for highly selective detection of PCP in water. The distinctive interaction between the size-selective poly-hydroxyproline helical peptide (PHHP) and poly(o-phenylenediamine) (p(o-PD)) molecularly imprinted films, strongly reduced non-specific adsorption. In the face of high concentrations of organic matters and ions, the reported sensor exhibited robust antifouling capabilities that it preserved 90 % of the initial signal. In addition, the limit of detection (LOD) reached an exceptionally low level of 1.13 nM (S/N = 3), spanning a wide linear range from 1 nM to 10 μM, and the sensor showed high selectivity with an impressive imprinted factor of 12.01 for PCP. Meanwhile, it owned great repeatability and reproducibility, long-term stability for PCP detection within 25 days, and decent reusability (retaining 92.33 % of its senor performance after 5 cycles), which ensured its excellent feasibility for determination of PCP in complex water samples with co-existing interferences due to acceptable recoveries. The development of this strategy provides an innovative platform for PCP quantification in real water samples, underscoring its potential as a key tool in managing PCP at relevant sites.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Sensors and Actuators B: Chemical
Sensors and Actuators B: Chemical 工程技术-电化学
CiteScore
14.60
自引率
11.90%
发文量
1776
审稿时长
3.2 months
期刊介绍: Sensors & Actuators, B: Chemical is an international journal focused on the research and development of chemical transducers. It covers chemical sensors and biosensors, chemical actuators, and analytical microsystems. The journal is interdisciplinary, aiming to publish original works showcasing substantial advancements beyond the current state of the art in these fields, with practical applicability to solving meaningful analytical problems. Review articles are accepted by invitation from an Editor of the journal.
期刊最新文献
An Anti-interference PEC-ECL Biosensing for Cancer-related Gene based on Self-supporting Semi-encapsulated Heterojunction Modulated Interface Polarity-Switching Highly sensitive and rapid optical fiber bio-sensor for endotoxin detection using anti-resonance effect MOF-derived La-doped ZnO Dodecahedron Nanostructures for Efficient Detection of NO2 Gas Synthesis of Heterostructured Nanocomposite MgFe2O4/MoO3 for H2S Sensing: Experimental and Theoretical approach by DFT Slight modification of a G-quadruplex-targeted quinoxaline may boost type-1 photodynamic therapy for triple-negative breast cancer
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1