静脉血中的酸碱参数--安全PICO注射器和锂肝素空采样管的数值之间的一致性。

IF 1.3 4区 医学 Q4 MEDICINE, RESEARCH & EXPERIMENTAL Scandinavian Journal of Clinical & Laboratory Investigation Pub Date : 2024-12-09 DOI:10.1080/00365513.2024.2420317
Linda Østervig Henriksen, Tina Windfeld, Willemijn Jansje Comuth, Anna-Marie Bloch Münster
{"title":"静脉血中的酸碱参数--安全PICO注射器和锂肝素空采样管的数值之间的一致性。","authors":"Linda Østervig Henriksen, Tina Windfeld, Willemijn Jansje Comuth, Anna-Marie Bloch Münster","doi":"10.1080/00365513.2024.2420317","DOIUrl":null,"url":null,"abstract":"<p><p>Venous blood is considered an acceptable alternative to arterial blood for assessment of metabolic acid-base disorders. Also, venous sampling using lithium-heparin (Li-Hep) tubes is advantageous to arterial sampling using PICO syringes, the risk of complications being lower. Usage of partly filled tubes without firm knowledge about the clinical consequences is, however, a pre-analytic consideration. The study evaluated primary acid-base parameters (pH, standardized hydrogen carbonate (HCO<sub>3</sub>), standardized base excess (SBE), lactate) and co-determined parameters in venous blood stored at room temperature up to 60 min in Li-Hep tubes vs. venous blood in PICO syringes analyzed immediately. Also, 50% filled tubes stored up to 30 min were compared to filled tubes analyzed immediately. Significant differences were generally observed. Stability was parameter and time dependent (filled tubes: 30 min: pH, (preferably 15 min for optimal stability), SBE, potassium and lactate, 60 min: HCO<sub>3</sub>, hemoglobin, methemoglobin (MetHb), carbon monoxide hemoglobin (COHb), sodium, chloride, glucose and creatinine; 50% filled tubes: 15 min: lactate, 30 min: HCO<sub>3</sub>, hemoglobin, MetHb, COHb, potassium, sodium, chloride, glucose and creatinine). In conclusion, storage in filled Li-Hep tubes for 30 min generates comparable results to blood in PICO syringes for all parameters, except pCO<sub>2</sub>, pO<sub>2</sub> and sO<sub>2</sub>. Storage in 50% filled Li-Hep tubes is not acceptable for pH, pCO<sub>2</sub>, pO<sub>2</sub>, sO<sub>2</sub> and SBE, and lactate is only stable for 15 min.</p>","PeriodicalId":21474,"journal":{"name":"Scandinavian Journal of Clinical & Laboratory Investigation","volume":" ","pages":"1-11"},"PeriodicalIF":1.3000,"publicationDate":"2024-12-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Acid-base parameters in venous blood - agreement between values from safePICO syringes and lithium-heparin vacutainer tubes.\",\"authors\":\"Linda Østervig Henriksen, Tina Windfeld, Willemijn Jansje Comuth, Anna-Marie Bloch Münster\",\"doi\":\"10.1080/00365513.2024.2420317\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Venous blood is considered an acceptable alternative to arterial blood for assessment of metabolic acid-base disorders. Also, venous sampling using lithium-heparin (Li-Hep) tubes is advantageous to arterial sampling using PICO syringes, the risk of complications being lower. Usage of partly filled tubes without firm knowledge about the clinical consequences is, however, a pre-analytic consideration. The study evaluated primary acid-base parameters (pH, standardized hydrogen carbonate (HCO<sub>3</sub>), standardized base excess (SBE), lactate) and co-determined parameters in venous blood stored at room temperature up to 60 min in Li-Hep tubes vs. venous blood in PICO syringes analyzed immediately. Also, 50% filled tubes stored up to 30 min were compared to filled tubes analyzed immediately. Significant differences were generally observed. Stability was parameter and time dependent (filled tubes: 30 min: pH, (preferably 15 min for optimal stability), SBE, potassium and lactate, 60 min: HCO<sub>3</sub>, hemoglobin, methemoglobin (MetHb), carbon monoxide hemoglobin (COHb), sodium, chloride, glucose and creatinine; 50% filled tubes: 15 min: lactate, 30 min: HCO<sub>3</sub>, hemoglobin, MetHb, COHb, potassium, sodium, chloride, glucose and creatinine). In conclusion, storage in filled Li-Hep tubes for 30 min generates comparable results to blood in PICO syringes for all parameters, except pCO<sub>2</sub>, pO<sub>2</sub> and sO<sub>2</sub>. Storage in 50% filled Li-Hep tubes is not acceptable for pH, pCO<sub>2</sub>, pO<sub>2</sub>, sO<sub>2</sub> and SBE, and lactate is only stable for 15 min.</p>\",\"PeriodicalId\":21474,\"journal\":{\"name\":\"Scandinavian Journal of Clinical & Laboratory Investigation\",\"volume\":\" \",\"pages\":\"1-11\"},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2024-12-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Scandinavian Journal of Clinical & Laboratory Investigation\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1080/00365513.2024.2420317\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"MEDICINE, RESEARCH & EXPERIMENTAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Scandinavian Journal of Clinical & Laboratory Investigation","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/00365513.2024.2420317","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"MEDICINE, RESEARCH & EXPERIMENTAL","Score":null,"Total":0}
引用次数: 0
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Acid-base parameters in venous blood - agreement between values from safePICO syringes and lithium-heparin vacutainer tubes.

Venous blood is considered an acceptable alternative to arterial blood for assessment of metabolic acid-base disorders. Also, venous sampling using lithium-heparin (Li-Hep) tubes is advantageous to arterial sampling using PICO syringes, the risk of complications being lower. Usage of partly filled tubes without firm knowledge about the clinical consequences is, however, a pre-analytic consideration. The study evaluated primary acid-base parameters (pH, standardized hydrogen carbonate (HCO3), standardized base excess (SBE), lactate) and co-determined parameters in venous blood stored at room temperature up to 60 min in Li-Hep tubes vs. venous blood in PICO syringes analyzed immediately. Also, 50% filled tubes stored up to 30 min were compared to filled tubes analyzed immediately. Significant differences were generally observed. Stability was parameter and time dependent (filled tubes: 30 min: pH, (preferably 15 min for optimal stability), SBE, potassium and lactate, 60 min: HCO3, hemoglobin, methemoglobin (MetHb), carbon monoxide hemoglobin (COHb), sodium, chloride, glucose and creatinine; 50% filled tubes: 15 min: lactate, 30 min: HCO3, hemoglobin, MetHb, COHb, potassium, sodium, chloride, glucose and creatinine). In conclusion, storage in filled Li-Hep tubes for 30 min generates comparable results to blood in PICO syringes for all parameters, except pCO2, pO2 and sO2. Storage in 50% filled Li-Hep tubes is not acceptable for pH, pCO2, pO2, sO2 and SBE, and lactate is only stable for 15 min.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.50
自引率
4.80%
发文量
85
审稿时长
4-8 weeks
期刊介绍: The Scandinavian Journal of Clinical and Laboratory Investigation is an international scientific journal covering clinically oriented biochemical and physiological research. Since the launch of the journal in 1949, it has been a forum for international laboratory medicine, closely related to, and edited by, The Scandinavian Society for Clinical Chemistry. The journal contains peer-reviewed articles, editorials, invited reviews, and short technical notes, as well as several supplements each year. Supplements consist of monographs, and symposium and congress reports covering subjects within clinical chemistry and clinical physiology.
期刊最新文献
Extending the Lund-Malmö creatinine-based GFR equation to cystatin C - validation results from the European Kidney Function Consortium (EKFC) cohort of children and adults. The course of plasma alpha-1-microglobulin and haemolysis during cardiac surgery and the relationship to acute kidney injury, a pilot study. Stability of bilirubin and oxyhaemoglobin in cerebrospinal fluid. Comparative analysis of protein expression profiles with genotypes in the diagnosis of Inborn Errors of Immunity. Sentinel testing, analytical sigma metrics and a risk management approach as part of a simplified method verification/validation process.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1