一个简单有效的筛查方案,以确定白内障患者的双眼视力异常。

IF 1.7 4区 医学 Q3 OPHTHALMOLOGY BMC Ophthalmology Pub Date : 2024-12-18 DOI:10.1186/s12886-024-03807-w
Qing-Qing Tan, Jia-Hao Tan, Chang-Kang Luo, Chun-Yan Lai, Wei Zhao, Chang-Jun Lan, James Lewis, Saeed Aljohani, Xuan Liao, Mitchell Scheiman
{"title":"一个简单有效的筛查方案,以确定白内障患者的双眼视力异常。","authors":"Qing-Qing Tan, Jia-Hao Tan, Chang-Kang Luo, Chun-Yan Lai, Wei Zhao, Chang-Jun Lan, James Lewis, Saeed Aljohani, Xuan Liao, Mitchell Scheiman","doi":"10.1186/s12886-024-03807-w","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>To compare the effectiveness of a brief binocular vision screening protocol to a comprehensive examination for detecting binocular vision anomalies before and after cataract surgery.</p><p><strong>Methods: </strong>A comprehensive binocular vision test battery as a gold standard were administered on recruited patients before the first surgery and at the third visit after surgery on the second eye. A receiver operating characteristic (ROC) curve was plotted to illustrate the diagnostic ability of each test. In addition, a univariate logistic regression analysis was performed to further determine the contribution of each preoperative test to the prediction of pre- and post-surgical binocular vision anomalies.</p><p><strong>Results: </strong>Significant differences were shown for the difference in phoria from distance to near measured by the cover test (Area Under Curve [AUC] = 0.96, P < 0.01), step vergence testing of positive fusional vergence at distance (AUC = 0.71, P < 0.01) and near (AUC = 0.77, P < 0.01). The other tests did not show statistically significant differences. The ROC curve generated by combining the difference in distance and near phoria with positive fusional vergence at both distance and near demonstrated a more robust measure of diagnostic accuracy. (AUC = 0.98, P < 0.01).</p><p><strong>Conclusion: </strong>Distance and near phoria difference measured by cover test has similar effectiveness as a comprehensive binocular vision testing protocol for the diagnosis of binocular vision anomalies. Distance and near positive fusional vergence measured by step vergence testing also have significant predictive value. A combination of the two tests is an outstanding screening protocol for binocular vision anomalies before cataract surgery.</p><p><strong>Trial registration: </strong>The study was registered at ClinicalTrials.gov (NCT03592615, Date of registration: July 19, 2018).</p>","PeriodicalId":9058,"journal":{"name":"BMC Ophthalmology","volume":"24 1","pages":"536"},"PeriodicalIF":1.7000,"publicationDate":"2024-12-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11657689/pdf/","citationCount":"0","resultStr":"{\"title\":\"A brief effective screening protocol for identifying cataract patients with binocular vision anomalies.\",\"authors\":\"Qing-Qing Tan, Jia-Hao Tan, Chang-Kang Luo, Chun-Yan Lai, Wei Zhao, Chang-Jun Lan, James Lewis, Saeed Aljohani, Xuan Liao, Mitchell Scheiman\",\"doi\":\"10.1186/s12886-024-03807-w\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>To compare the effectiveness of a brief binocular vision screening protocol to a comprehensive examination for detecting binocular vision anomalies before and after cataract surgery.</p><p><strong>Methods: </strong>A comprehensive binocular vision test battery as a gold standard were administered on recruited patients before the first surgery and at the third visit after surgery on the second eye. A receiver operating characteristic (ROC) curve was plotted to illustrate the diagnostic ability of each test. In addition, a univariate logistic regression analysis was performed to further determine the contribution of each preoperative test to the prediction of pre- and post-surgical binocular vision anomalies.</p><p><strong>Results: </strong>Significant differences were shown for the difference in phoria from distance to near measured by the cover test (Area Under Curve [AUC] = 0.96, P < 0.01), step vergence testing of positive fusional vergence at distance (AUC = 0.71, P < 0.01) and near (AUC = 0.77, P < 0.01). The other tests did not show statistically significant differences. The ROC curve generated by combining the difference in distance and near phoria with positive fusional vergence at both distance and near demonstrated a more robust measure of diagnostic accuracy. (AUC = 0.98, P < 0.01).</p><p><strong>Conclusion: </strong>Distance and near phoria difference measured by cover test has similar effectiveness as a comprehensive binocular vision testing protocol for the diagnosis of binocular vision anomalies. Distance and near positive fusional vergence measured by step vergence testing also have significant predictive value. A combination of the two tests is an outstanding screening protocol for binocular vision anomalies before cataract surgery.</p><p><strong>Trial registration: </strong>The study was registered at ClinicalTrials.gov (NCT03592615, Date of registration: July 19, 2018).</p>\",\"PeriodicalId\":9058,\"journal\":{\"name\":\"BMC Ophthalmology\",\"volume\":\"24 1\",\"pages\":\"536\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2024-12-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11657689/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"BMC Ophthalmology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1186/s12886-024-03807-w\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12886-024-03807-w","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

背景:比较简单的双眼视力筛查方案与综合检查在白内障手术前后检测双眼视力异常的有效性。方法:对入选患者在第一次手术前和第二眼手术后第三次复诊时进行双目综合视力测试,并将其作为金标准。绘制受试者工作特征(ROC)曲线来说明每个测试的诊断能力。此外,我们还进行了单变量logistic回归分析,以进一步确定每种术前检查对预测术前和术后双眼视力异常的贡献。结果:覆盖试验测得的远视距与近视距差异有显著性差异(曲线下面积[AUC] = 0.96, P)。结论:覆盖试验测得的远视距与近视距差异作为双目视力综合检测方案诊断双眼视力异常的效果相似。步进收敛检验测量的距离和近正融合收敛也具有显著的预测价值。这两项检查的结合是白内障手术前双眼视力异常的杰出筛查方案。试验注册:该研究已在ClinicalTrials.gov注册(NCT03592615,注册日期:2018年7月19日)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A brief effective screening protocol for identifying cataract patients with binocular vision anomalies.

Background: To compare the effectiveness of a brief binocular vision screening protocol to a comprehensive examination for detecting binocular vision anomalies before and after cataract surgery.

Methods: A comprehensive binocular vision test battery as a gold standard were administered on recruited patients before the first surgery and at the third visit after surgery on the second eye. A receiver operating characteristic (ROC) curve was plotted to illustrate the diagnostic ability of each test. In addition, a univariate logistic regression analysis was performed to further determine the contribution of each preoperative test to the prediction of pre- and post-surgical binocular vision anomalies.

Results: Significant differences were shown for the difference in phoria from distance to near measured by the cover test (Area Under Curve [AUC] = 0.96, P < 0.01), step vergence testing of positive fusional vergence at distance (AUC = 0.71, P < 0.01) and near (AUC = 0.77, P < 0.01). The other tests did not show statistically significant differences. The ROC curve generated by combining the difference in distance and near phoria with positive fusional vergence at both distance and near demonstrated a more robust measure of diagnostic accuracy. (AUC = 0.98, P < 0.01).

Conclusion: Distance and near phoria difference measured by cover test has similar effectiveness as a comprehensive binocular vision testing protocol for the diagnosis of binocular vision anomalies. Distance and near positive fusional vergence measured by step vergence testing also have significant predictive value. A combination of the two tests is an outstanding screening protocol for binocular vision anomalies before cataract surgery.

Trial registration: The study was registered at ClinicalTrials.gov (NCT03592615, Date of registration: July 19, 2018).

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
BMC Ophthalmology
BMC Ophthalmology OPHTHALMOLOGY-
CiteScore
3.40
自引率
5.00%
发文量
441
审稿时长
6-12 weeks
期刊介绍: BMC Ophthalmology is an open access, peer-reviewed journal that considers articles on all aspects of the prevention, diagnosis and management of eye disorders, as well as related molecular genetics, pathophysiology, and epidemiology.
期刊最新文献
Comparing structural and vascular parameters between advanced pseudoexfoliation glaucoma and primary open angle glaucoma using optical coherence tomography angiography. Phaeoisaria sp. fungal keratitis resembling corneal rust residue: a case report. Quantitative evaluation of the wide-field fundus photographs in eyes with severe stage 3 and stage 4A retinopathy of prematurity. Incidence of ophthalmic manifestations in congenital cytomegalovirus (CMV). Increased aqueous humor levels of endothelin-1 in patients with open angle glaucoma.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1