不同b值组合的合成弥散加权成像在前列腺癌诊断中的比较研究

IF 2.1 3区 医学 Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Clinical radiology Pub Date : 2024-12-07 DOI:10.1016/j.crad.2024.106770
L He, Z Zhang, J Zhang, J Xia, Y Wang, J Zhu
{"title":"不同b值组合的合成弥散加权成像在前列腺癌诊断中的比较研究","authors":"L He, Z Zhang, J Zhang, J Xia, Y Wang, J Zhu","doi":"10.1016/j.crad.2024.106770","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>To evaluate the impact of different b-value combinations on synthetic diffusion-weighted imaging (sDWI) and determine the sDWI with an optimal b-value combination for prostatic cancer (PCa) diagnosis.</p><p><strong>Material and methods: </strong>A retrospective analysis of 68 patients with abnormal prostate-specific antigen (PSA) was conducted. The sDWI images with b value of 1500 s/mm<sup>2</sup> were separately reconstructed by the following five b-value combinations: b=0, 200s/mm<sup>2</sup> (sDWI<sub>0-200</sub>); b=600, 800s/mm<sup>2</sup> (sDWI<sub>600-800</sub>); b=0, 600s/mm<sup>2</sup> (sDWI<sub>0-600</sub>); b=200, 800s/mm<sup>2</sup> sDWI<sub>200-800</sub>); b=0, 800s/mm<sup>2</sup> (sDWI<sub>0-800</sub>). Quantitative analysis was performed on the acquired DWI (aDWI) images with b=1500s/mm<sup>2</sup> (aDWI<sub>1500</sub>) and all sDWI images. These six image groups were scored in five aspects for image quality and further reviewed by two radiologists via six protocols: Protocol Ⅰ, T<sub>2</sub>WI+sDWI<sub>0-200</sub>; Protocol Ⅱ, T<sub>2</sub>WI+sDWI<sub>600-800</sub>; Protocol Ⅲ, T<sub>2</sub>WI+sDWI<sub>0-600</sub>; Protocol Ⅳ, T<sub>2</sub>WI+sDWI<sub>200-800</sub>; Protocol Ⅴ, T<sub>2</sub>WI+sDWI<sub>0-800</sub>; Protocol Ⅵ, T<sub>2</sub>WI+aDWI<sub>1500</sub>. The corresponding diagnostic efficacies for PCa were evaluated using receiver operating characteristic (ROC) curves.</p><p><strong>Results: </strong>Contrast ratio values of all sDWI images were higher than those of aDWI<sub>1500</sub> images. Contrast-to-noise ratio values of sDWI<sub>0-200</sub> and sDWI<sub>600-800</sub> images were lower than those of the rest sDWI images. All subjective quality scores of sDWI<sub>0-600</sub>, sDWI<sub>200-800,</sub> and sDWI<sub>0-800</sub> were significantly higher than other groups except for background signal suppression. The area under the curve (AUC) of Protocol Ⅲ, Ⅳ, Ⅴ, and Ⅵ was significantly larger than those of other protocols.</p><p><strong>Conclusion: </strong>Different b-value combinations impact the image quality and diagnostic accuracy of sDWI for PCa detection. The combination of b≤200s/mm<sup>2</sup> and b≥600s/mm<sup>2</sup> revealed to be optimal.</p>","PeriodicalId":10695,"journal":{"name":"Clinical radiology","volume":"81 ","pages":"106770"},"PeriodicalIF":2.1000,"publicationDate":"2024-12-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Synthetic diffusion-weighted imaging in prostate cancer diagnosis: a comparison study with different B-value combinations.\",\"authors\":\"L He, Z Zhang, J Zhang, J Xia, Y Wang, J Zhu\",\"doi\":\"10.1016/j.crad.2024.106770\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Aim: </strong>To evaluate the impact of different b-value combinations on synthetic diffusion-weighted imaging (sDWI) and determine the sDWI with an optimal b-value combination for prostatic cancer (PCa) diagnosis.</p><p><strong>Material and methods: </strong>A retrospective analysis of 68 patients with abnormal prostate-specific antigen (PSA) was conducted. The sDWI images with b value of 1500 s/mm<sup>2</sup> were separately reconstructed by the following five b-value combinations: b=0, 200s/mm<sup>2</sup> (sDWI<sub>0-200</sub>); b=600, 800s/mm<sup>2</sup> (sDWI<sub>600-800</sub>); b=0, 600s/mm<sup>2</sup> (sDWI<sub>0-600</sub>); b=200, 800s/mm<sup>2</sup> sDWI<sub>200-800</sub>); b=0, 800s/mm<sup>2</sup> (sDWI<sub>0-800</sub>). Quantitative analysis was performed on the acquired DWI (aDWI) images with b=1500s/mm<sup>2</sup> (aDWI<sub>1500</sub>) and all sDWI images. These six image groups were scored in five aspects for image quality and further reviewed by two radiologists via six protocols: Protocol Ⅰ, T<sub>2</sub>WI+sDWI<sub>0-200</sub>; Protocol Ⅱ, T<sub>2</sub>WI+sDWI<sub>600-800</sub>; Protocol Ⅲ, T<sub>2</sub>WI+sDWI<sub>0-600</sub>; Protocol Ⅳ, T<sub>2</sub>WI+sDWI<sub>200-800</sub>; Protocol Ⅴ, T<sub>2</sub>WI+sDWI<sub>0-800</sub>; Protocol Ⅵ, T<sub>2</sub>WI+aDWI<sub>1500</sub>. The corresponding diagnostic efficacies for PCa were evaluated using receiver operating characteristic (ROC) curves.</p><p><strong>Results: </strong>Contrast ratio values of all sDWI images were higher than those of aDWI<sub>1500</sub> images. Contrast-to-noise ratio values of sDWI<sub>0-200</sub> and sDWI<sub>600-800</sub> images were lower than those of the rest sDWI images. All subjective quality scores of sDWI<sub>0-600</sub>, sDWI<sub>200-800,</sub> and sDWI<sub>0-800</sub> were significantly higher than other groups except for background signal suppression. The area under the curve (AUC) of Protocol Ⅲ, Ⅳ, Ⅴ, and Ⅵ was significantly larger than those of other protocols.</p><p><strong>Conclusion: </strong>Different b-value combinations impact the image quality and diagnostic accuracy of sDWI for PCa detection. The combination of b≤200s/mm<sup>2</sup> and b≥600s/mm<sup>2</sup> revealed to be optimal.</p>\",\"PeriodicalId\":10695,\"journal\":{\"name\":\"Clinical radiology\",\"volume\":\"81 \",\"pages\":\"106770\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2024-12-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical radiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1016/j.crad.2024.106770\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical radiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.crad.2024.106770","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

目的:评价不同b值组合对合成弥散加权成像(sDWI)的影响,确定诊断前列腺癌(PCa)的最佳b值组合sDWI。材料与方法:对68例前列腺特异性抗原(PSA)异常患者进行回顾性分析。对b值为1500 s/mm2的sDWI图像分别采用以下5种b值组合进行重建:b= 0,200 s/mm2 (sDWI0-200);b= 600,800s /mm2 (sDWI600-800);b= 0,600 s/mm2 (sDWI0-600);b= 200,800s /mm2 (sDWI200-800);b= 0,800s /mm2 (sDWI0-800)。对采集的b=1500s/mm2的DWI (aDWI)图像(aDWI1500)和所有sDWI图像进行定量分析。这六个图像组从五个方面对图像质量进行评分,并由两名放射科医生通过六个协议进行进一步审查:协议Ⅰ,T2WI+sDWI0-200;协议Ⅱ,T2WI+sDWI600-800;协议Ⅲ,T2WI+sDWI0-600;协议Ⅳ,T2WI+sDWI200-800;协议Ⅴ,T2WI+sDWI0-800;协议Ⅵ,T2WI+aDWI1500。采用受试者工作特征(ROC)曲线评价前列腺癌的诊断效果。结果:所有sDWI图像的对比度值均高于aDWI1500图像。sDWI0-200和sDWI600-800图像的噪比值低于其他sDWI图像。除背景信号抑制外,sDWI0-600、sDWI200-800、sDWI0-800主观质量得分均显著高于其他各组。方案Ⅲ、Ⅳ、Ⅴ和Ⅵ的曲线下面积(area under The curve, AUC)明显大于其他方案。结论:不同的b值组合会影响sDWI对PCa检测的图像质量和诊断准确性。b≤200s/mm2和b≥600s/mm2的组合效果最佳。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Synthetic diffusion-weighted imaging in prostate cancer diagnosis: a comparison study with different B-value combinations.

Aim: To evaluate the impact of different b-value combinations on synthetic diffusion-weighted imaging (sDWI) and determine the sDWI with an optimal b-value combination for prostatic cancer (PCa) diagnosis.

Material and methods: A retrospective analysis of 68 patients with abnormal prostate-specific antigen (PSA) was conducted. The sDWI images with b value of 1500 s/mm2 were separately reconstructed by the following five b-value combinations: b=0, 200s/mm2 (sDWI0-200); b=600, 800s/mm2 (sDWI600-800); b=0, 600s/mm2 (sDWI0-600); b=200, 800s/mm2 sDWI200-800); b=0, 800s/mm2 (sDWI0-800). Quantitative analysis was performed on the acquired DWI (aDWI) images with b=1500s/mm2 (aDWI1500) and all sDWI images. These six image groups were scored in five aspects for image quality and further reviewed by two radiologists via six protocols: Protocol Ⅰ, T2WI+sDWI0-200; Protocol Ⅱ, T2WI+sDWI600-800; Protocol Ⅲ, T2WI+sDWI0-600; Protocol Ⅳ, T2WI+sDWI200-800; Protocol Ⅴ, T2WI+sDWI0-800; Protocol Ⅵ, T2WI+aDWI1500. The corresponding diagnostic efficacies for PCa were evaluated using receiver operating characteristic (ROC) curves.

Results: Contrast ratio values of all sDWI images were higher than those of aDWI1500 images. Contrast-to-noise ratio values of sDWI0-200 and sDWI600-800 images were lower than those of the rest sDWI images. All subjective quality scores of sDWI0-600, sDWI200-800, and sDWI0-800 were significantly higher than other groups except for background signal suppression. The area under the curve (AUC) of Protocol Ⅲ, Ⅳ, Ⅴ, and Ⅵ was significantly larger than those of other protocols.

Conclusion: Different b-value combinations impact the image quality and diagnostic accuracy of sDWI for PCa detection. The combination of b≤200s/mm2 and b≥600s/mm2 revealed to be optimal.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Clinical radiology
Clinical radiology 医学-核医学
CiteScore
4.70
自引率
3.80%
发文量
528
审稿时长
76 days
期刊介绍: Clinical Radiology is published by Elsevier on behalf of The Royal College of Radiologists. Clinical Radiology is an International Journal bringing you original research, editorials and review articles on all aspects of diagnostic imaging, including: • Computed tomography • Magnetic resonance imaging • Ultrasonography • Digital radiology • Interventional radiology • Radiography • Nuclear medicine Papers on radiological protection, quality assurance, audit in radiology and matters relating to radiological training and education are also included. In addition, each issue contains correspondence, book reviews and notices of forthcoming events.
期刊最新文献
Corrigendum to "CT histogram analysis to distinguish between acute intracerebral hemorrhage and cavernous hemangioma" [Clin Radiol 79 (11) (2024) e872-e879]. Re: Utility of zero echo time (ZTE) sequence for assessing bony lesions of skull base and calvarium. Measurement of lumbar vertebral body attenuation at PET-CT is a reliable method of diagnosing osteoporosis Safety of CT-guided percutaneous cryoablation in patients treated for clinical T1 renal cell carcinoma with the need for pre-procedural ureteral stenting: an international cohort study Correlation of semi-quantitative analyses and visual scores in pulmonary perfusion SPECT/CT imaging with pulmonary function test parameters in patients with interstitial lung diseases
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1