不要介意间隙:利用虚拟力学测试的见解重新构建Perren应变规则用于骨折愈合。

IF 4.7 2区 医学 Q2 CELL & TISSUE ENGINEERING Bone & Joint Research Pub Date : 2025-01-01 DOI:10.1302/2046-3758.141.BJR-2024-0191.R2
Maham Tanveer, Karina Klein, Brigitte von Rechenberg, Salim Darwiche, Hannah L Dailey
{"title":"不要介意间隙:利用虚拟力学测试的见解重新构建Perren应变规则用于骨折愈合。","authors":"Maham Tanveer, Karina Klein, Brigitte von Rechenberg, Salim Darwiche, Hannah L Dailey","doi":"10.1302/2046-3758.141.BJR-2024-0191.R2","DOIUrl":null,"url":null,"abstract":"<p><strong>Aims: </strong>The \"2 to 10% strain rule\" for fracture healing has been widely interpreted to mean that interfragmentary strain greater than 10% predisposes a fracture to nonunion. This interpretation focuses on the gap-closing strain (axial micromotion divided by gap size), ignoring the region around the gap where osteogenesis typically initiates. The aim of this study was to measure gap-closing and 3D interfragmentary strains in plated ovine osteotomies and associate local strain conditions with callus mineralization.</p><p><strong>Methods: </strong>MicroCT scans of eight female sheep with plated mid-shaft tibial osteotomies were used to create image-based finite element models. Virtual mechanical testing was used to compute postoperative gap-closing and 3D continuum strains representing compression (volumetric strain) and shear deformation (distortional strain). Callus mineralization was measured in zones in and around the osteotomy gap.</p><p><strong>Results: </strong>Gap-closing strains averaged 51% (mean) at the far cortex. Peak compressive volumetric strain averaged 32% and only a small tissue volume (average 0.3 cm<sup>3</sup>) within the gap experienced compressive strains > 10%. Distortional strains were much higher and more widespread, peaking at a mean of 115%, with a mean of 3.3 cm<sup>3</sup> of tissue in and around the osteotomy experiencing distortional strains > 10%. Callus mineralization initiated outside the high-strain gap and was significantly lower within the fracture gap compared to around it at nine weeks.</p><p><strong>Conclusion: </strong>Ovine osteotomies can heal with high gap strains (> 10%) dominated by shear conditions. High gap strain appears to be a transient local limiter of osteogenesis, not a global inhibitor of secondary fracture repair.</p>","PeriodicalId":9074,"journal":{"name":"Bone & Joint Research","volume":"14 1","pages":"5-15"},"PeriodicalIF":4.7000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11688128/pdf/","citationCount":"0","resultStr":"{\"title\":\"Don't mind the gap: reframing the Perren strain rule for fracture healing using insights from virtual mechanical testing.\",\"authors\":\"Maham Tanveer, Karina Klein, Brigitte von Rechenberg, Salim Darwiche, Hannah L Dailey\",\"doi\":\"10.1302/2046-3758.141.BJR-2024-0191.R2\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Aims: </strong>The \\\"2 to 10% strain rule\\\" for fracture healing has been widely interpreted to mean that interfragmentary strain greater than 10% predisposes a fracture to nonunion. This interpretation focuses on the gap-closing strain (axial micromotion divided by gap size), ignoring the region around the gap where osteogenesis typically initiates. The aim of this study was to measure gap-closing and 3D interfragmentary strains in plated ovine osteotomies and associate local strain conditions with callus mineralization.</p><p><strong>Methods: </strong>MicroCT scans of eight female sheep with plated mid-shaft tibial osteotomies were used to create image-based finite element models. Virtual mechanical testing was used to compute postoperative gap-closing and 3D continuum strains representing compression (volumetric strain) and shear deformation (distortional strain). Callus mineralization was measured in zones in and around the osteotomy gap.</p><p><strong>Results: </strong>Gap-closing strains averaged 51% (mean) at the far cortex. Peak compressive volumetric strain averaged 32% and only a small tissue volume (average 0.3 cm<sup>3</sup>) within the gap experienced compressive strains > 10%. Distortional strains were much higher and more widespread, peaking at a mean of 115%, with a mean of 3.3 cm<sup>3</sup> of tissue in and around the osteotomy experiencing distortional strains > 10%. Callus mineralization initiated outside the high-strain gap and was significantly lower within the fracture gap compared to around it at nine weeks.</p><p><strong>Conclusion: </strong>Ovine osteotomies can heal with high gap strains (> 10%) dominated by shear conditions. High gap strain appears to be a transient local limiter of osteogenesis, not a global inhibitor of secondary fracture repair.</p>\",\"PeriodicalId\":9074,\"journal\":{\"name\":\"Bone & Joint Research\",\"volume\":\"14 1\",\"pages\":\"5-15\"},\"PeriodicalIF\":4.7000,\"publicationDate\":\"2025-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11688128/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Bone & Joint Research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1302/2046-3758.141.BJR-2024-0191.R2\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CELL & TISSUE ENGINEERING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bone & Joint Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1302/2046-3758.141.BJR-2024-0191.R2","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CELL & TISSUE ENGINEERING","Score":null,"Total":0}
引用次数: 0

摘要

目的:骨折愈合的“2 - 10%应变规则”被广泛解释为骨折块间应变大于10%易导致骨折不愈合。这种解释侧重于裂缝闭合应变(轴向微动除以裂缝大小),忽略了裂缝周围通常开始成骨的区域。本研究的目的是测量间隙关闭和3D碎片间应变在镀羊截骨术和局部应变条件与愈伤组织矿化的关联。方法:对8只母羊行胫骨中骨截骨术,采用微ct扫描建立基于图像的有限元模型。虚拟力学测试用于计算术后间隙闭合和代表压缩(体积应变)和剪切变形(扭曲应变)的三维连续应变。在截骨间隙内和周围区域测量骨痂矿化。结果:在远端皮质区,缺口闭合应变平均为51%(平均值)。峰值压缩体积应变平均为32%,间隙内只有很小的组织体积(平均为0.3 cm3)经历压缩应变bbb10 %。畸变应变高得多,分布也广得多,峰值平均为115%,截骨术内及周围平均3.3 cm3的组织出现畸变应变bbb10 %。伤愈组织矿化始于高应变间隙外,在骨折间隙内的矿化明显低于骨折间隙周围。结论:以剪切条件为主的高间隙应变(bbb10 %)可使羊截骨愈合。高间隙应变似乎是一种短暂的局部成骨限制,而不是二次骨折修复的全局抑制剂。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Don't mind the gap: reframing the Perren strain rule for fracture healing using insights from virtual mechanical testing.

Aims: The "2 to 10% strain rule" for fracture healing has been widely interpreted to mean that interfragmentary strain greater than 10% predisposes a fracture to nonunion. This interpretation focuses on the gap-closing strain (axial micromotion divided by gap size), ignoring the region around the gap where osteogenesis typically initiates. The aim of this study was to measure gap-closing and 3D interfragmentary strains in plated ovine osteotomies and associate local strain conditions with callus mineralization.

Methods: MicroCT scans of eight female sheep with plated mid-shaft tibial osteotomies were used to create image-based finite element models. Virtual mechanical testing was used to compute postoperative gap-closing and 3D continuum strains representing compression (volumetric strain) and shear deformation (distortional strain). Callus mineralization was measured in zones in and around the osteotomy gap.

Results: Gap-closing strains averaged 51% (mean) at the far cortex. Peak compressive volumetric strain averaged 32% and only a small tissue volume (average 0.3 cm3) within the gap experienced compressive strains > 10%. Distortional strains were much higher and more widespread, peaking at a mean of 115%, with a mean of 3.3 cm3 of tissue in and around the osteotomy experiencing distortional strains > 10%. Callus mineralization initiated outside the high-strain gap and was significantly lower within the fracture gap compared to around it at nine weeks.

Conclusion: Ovine osteotomies can heal with high gap strains (> 10%) dominated by shear conditions. High gap strain appears to be a transient local limiter of osteogenesis, not a global inhibitor of secondary fracture repair.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Bone & Joint Research
Bone & Joint Research CELL & TISSUE ENGINEERING-ORTHOPEDICS
CiteScore
7.40
自引率
23.90%
发文量
156
审稿时长
12 weeks
期刊介绍: The gold open access journal for the musculoskeletal sciences. Included in PubMed and available in PubMed Central.
期刊最新文献
Clinical efficacy and safety of P-15 peptide enhanced bone graft substitute in surgical bone regenerative procedures in adult maxillofacial, spine, and trauma patients : a systematic literature review. Comparison of fore- and midfoot angles using 3DCT in standard weightbearing and sesamoid view position in feet with hallux valgus. Changes in the shape of the lumbar curve during growth : a geometric morphometric approach. Prediction of implant failure risk due to periprosthetic femoral fracture after primary elective total hip arthroplasty : a simplified and validated model based on 154,519 total hip arthroplasties from the Swedish Arthroplasty Register. Periprosthetic joint infections: navigating innovations and potential translation.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1