Hemant Ramesh Chourasia, Hitesh Chohan, Arwa Al-Maswary, Hadi Hassan Ghazwani, Hafiz Hadi Harbi, Nouh Hassan Khormi, Harisha Dewan, Hashim Bajawi, Mohammed Y Tarrosh
{"title":"Edgefile X7与HyFlex EDM在下颌磨牙中度弯曲中颊根管中根管定心与输送的比较分析。","authors":"Hemant Ramesh Chourasia, Hitesh Chohan, Arwa Al-Maswary, Hadi Hassan Ghazwani, Hafiz Hadi Harbi, Nouh Hassan Khormi, Harisha Dewan, Hashim Bajawi, Mohammed Y Tarrosh","doi":"10.12659/MSM.946794","DOIUrl":null,"url":null,"abstract":"<p><p>BACKGROUND This cone beam computed tomography (CBCT) endodontics study aimed to compare the canal-centering ability and canal transportation of Edgefile X7 and HyFlex EDM files in moderately curved mesiobuccal (MB) root canals of 30 mandibular first permanent molar teeth. MATERIAL AND METHODS Thirty permanent mandibular first molars with 10° and 24° of mesial root curvature were selected and scanned with CBCT. Two experimental groups of 15 each were made: group I: HyFlex EDM, and group II: Edgefile X7. The MB canals were instrumented, and CBCT scans were repeated. The distance from MB canal to the outer wall of the root was measured on pre- and post-instrumentation scans at 3 mm, 6 mm, and 9 mm from the apex. Canal transportation and centering ability were determined using established calculation methods. RESULTS For HyFlex EDM, average canal transportation was 0.01±0.17 mm, -0.10±0.21 mm, and 0.03±0.33 mm at 3 mm, 6 mm, and 9 mm, respectively; for Edgefile X7, average canal transportation was -0.02±0.21 mm, 0.07±0.22 mm, and -0.12±0.23 mm, respectively. HyFlex EDM group showed considerable canal transportation at 6 mm (P<0.05), while both groups showed non-significant differences at 3 mm and 9 mm. CONCLUSIONS At levels of 3 mm, 6 mm, and 9 mm, canal transportation was observed either on the mesial or distal surface of the canal curvature by HyFlex EDM and Edgefile X7 file systems. Compared with the HyFlex EDM file system, the Edgefile X7 file system showed reduced canal transportation and improved canal-centering ability.</p>","PeriodicalId":48888,"journal":{"name":"Medical Science Monitor","volume":"31 ","pages":"e946794"},"PeriodicalIF":3.1000,"publicationDate":"2025-01-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11705741/pdf/","citationCount":"0","resultStr":"{\"title\":\"Comparative Analysis of Canal Centering and Transportation: Edgefile X7 vs HyFlex EDM in Moderately Curved Mesiobuccal Root Canals of Mandibular Molars.\",\"authors\":\"Hemant Ramesh Chourasia, Hitesh Chohan, Arwa Al-Maswary, Hadi Hassan Ghazwani, Hafiz Hadi Harbi, Nouh Hassan Khormi, Harisha Dewan, Hashim Bajawi, Mohammed Y Tarrosh\",\"doi\":\"10.12659/MSM.946794\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>BACKGROUND This cone beam computed tomography (CBCT) endodontics study aimed to compare the canal-centering ability and canal transportation of Edgefile X7 and HyFlex EDM files in moderately curved mesiobuccal (MB) root canals of 30 mandibular first permanent molar teeth. MATERIAL AND METHODS Thirty permanent mandibular first molars with 10° and 24° of mesial root curvature were selected and scanned with CBCT. Two experimental groups of 15 each were made: group I: HyFlex EDM, and group II: Edgefile X7. The MB canals were instrumented, and CBCT scans were repeated. The distance from MB canal to the outer wall of the root was measured on pre- and post-instrumentation scans at 3 mm, 6 mm, and 9 mm from the apex. Canal transportation and centering ability were determined using established calculation methods. RESULTS For HyFlex EDM, average canal transportation was 0.01±0.17 mm, -0.10±0.21 mm, and 0.03±0.33 mm at 3 mm, 6 mm, and 9 mm, respectively; for Edgefile X7, average canal transportation was -0.02±0.21 mm, 0.07±0.22 mm, and -0.12±0.23 mm, respectively. HyFlex EDM group showed considerable canal transportation at 6 mm (P<0.05), while both groups showed non-significant differences at 3 mm and 9 mm. CONCLUSIONS At levels of 3 mm, 6 mm, and 9 mm, canal transportation was observed either on the mesial or distal surface of the canal curvature by HyFlex EDM and Edgefile X7 file systems. Compared with the HyFlex EDM file system, the Edgefile X7 file system showed reduced canal transportation and improved canal-centering ability.</p>\",\"PeriodicalId\":48888,\"journal\":{\"name\":\"Medical Science Monitor\",\"volume\":\"31 \",\"pages\":\"e946794\"},\"PeriodicalIF\":3.1000,\"publicationDate\":\"2025-01-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11705741/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Medical Science Monitor\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.12659/MSM.946794\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical Science Monitor","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.12659/MSM.946794","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Medicine","Score":null,"Total":0}
Comparative Analysis of Canal Centering and Transportation: Edgefile X7 vs HyFlex EDM in Moderately Curved Mesiobuccal Root Canals of Mandibular Molars.
BACKGROUND This cone beam computed tomography (CBCT) endodontics study aimed to compare the canal-centering ability and canal transportation of Edgefile X7 and HyFlex EDM files in moderately curved mesiobuccal (MB) root canals of 30 mandibular first permanent molar teeth. MATERIAL AND METHODS Thirty permanent mandibular first molars with 10° and 24° of mesial root curvature were selected and scanned with CBCT. Two experimental groups of 15 each were made: group I: HyFlex EDM, and group II: Edgefile X7. The MB canals were instrumented, and CBCT scans were repeated. The distance from MB canal to the outer wall of the root was measured on pre- and post-instrumentation scans at 3 mm, 6 mm, and 9 mm from the apex. Canal transportation and centering ability were determined using established calculation methods. RESULTS For HyFlex EDM, average canal transportation was 0.01±0.17 mm, -0.10±0.21 mm, and 0.03±0.33 mm at 3 mm, 6 mm, and 9 mm, respectively; for Edgefile X7, average canal transportation was -0.02±0.21 mm, 0.07±0.22 mm, and -0.12±0.23 mm, respectively. HyFlex EDM group showed considerable canal transportation at 6 mm (P<0.05), while both groups showed non-significant differences at 3 mm and 9 mm. CONCLUSIONS At levels of 3 mm, 6 mm, and 9 mm, canal transportation was observed either on the mesial or distal surface of the canal curvature by HyFlex EDM and Edgefile X7 file systems. Compared with the HyFlex EDM file system, the Edgefile X7 file system showed reduced canal transportation and improved canal-centering ability.
期刊介绍:
Medical Science Monitor (MSM) established in 1995 is an international, peer-reviewed scientific journal which publishes original articles in Clinical Medicine and related disciplines such as Epidemiology and Population Studies, Product Investigations, Development of Laboratory Techniques :: Diagnostics and Medical Technology which enable presentation of research or review works in overlapping areas of medicine and technology such us (but not limited to): medical diagnostics, medical imaging systems, computer simulation of health and disease processes, new medical devices, etc. Reviews and Special Reports - papers may be accepted on the basis that they provide a systematic, critical and up-to-date overview of literature pertaining to research or clinical topics. Meta-analyses are considered as reviews. A special attention will be paid to a teaching value of a review paper.
Medical Science Monitor is internationally indexed in Thomson-Reuters Web of Science, Journals Citation Report (JCR), Science Citation Index Expanded (SCI), Index Medicus MEDLINE, PubMed, PMC, EMBASE/Excerpta Medica, Chemical Abstracts CAS and Index Copernicus.