Adi Hertz , Michael Jerdev , Liza Grosman-Rimon , Itiel Ben-Zakai , Jordan Rimon , Offer Amir , Gabby Elbaz Greener , Shemy Carasso
{"title":"应用超声心动图特征跟踪软件对有或无明显冠心病患者进行心脏计算机断层血管造影的心肌功能评估。","authors":"Adi Hertz , Michael Jerdev , Liza Grosman-Rimon , Itiel Ben-Zakai , Jordan Rimon , Offer Amir , Gabby Elbaz Greener , Shemy Carasso","doi":"10.1016/j.ijcha.2024.101586","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction</h3><div>Cardiac computerized tomographic angiography (CCTA) is perceived as a non-invasive tool for assessment of coronary vessel anatomy. Feature tracking echocardiography has recently emerged as a tool for assessment of regional and global left ventricular function. We aimed to explore the applicability of echocardiographic strain on CCTA cine clips and assess whether global and regional strain parameters are associated with the extent of coronary stenosis.</div></div><div><h3>Methods</h3><div>CCTA studies of 61 consecutive patients were reconstructed to yield cine images in classic echocardiographic long and short views. Siemens Velocity Vector Imaging (VVI) software was applied to generate strain and displacement results. Volumetric and mechanics parameters were compared among patients with no or non-significant coronary artery disease (CAD) and patients with significant CAD. Finally, a comparison of the degree of coronary stenosis to regional segmental strain was performed.</div></div><div><h3>Results</h3><div>Myocardial mechanics parameters could be generated in 60 cases. Ejection fraction (EF) and left ventricular end diastolic volume (LVEDV) were within the normal range in both groups. VVI values were lower in the CAD group (VVI LVEF 59 ± 6 vs. 50 ± 11, p = 0.0002). Global longitudinal and global circumferential strain both were significantly lower in this group. Regional segmental strain was lower in segments affected by coronary stenosis in comparison to unaffected segments.</div></div><div><h3>Conclusion</h3><div>While CT segmentation derived LVEF did not differ among groups, patients with significant coronary stenosis had reduced longitudinal and circumferential contraction. This suggests that application of VVI to CCTA cine clips tracking may help to differentiate significant and non-significant coronary stenosis, adding functional value to anatomic findings in CCTA.</div></div>","PeriodicalId":38026,"journal":{"name":"IJC Heart and Vasculature","volume":"56 ","pages":"Article 101586"},"PeriodicalIF":2.5000,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11742848/pdf/","citationCount":"0","resultStr":"{\"title\":\"Functional myocardial assessment in cine cardiac computerized tomographic angiography using echocardiographic feature-tracking software in patients with and without significant coronary disease\",\"authors\":\"Adi Hertz , Michael Jerdev , Liza Grosman-Rimon , Itiel Ben-Zakai , Jordan Rimon , Offer Amir , Gabby Elbaz Greener , Shemy Carasso\",\"doi\":\"10.1016/j.ijcha.2024.101586\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Introduction</h3><div>Cardiac computerized tomographic angiography (CCTA) is perceived as a non-invasive tool for assessment of coronary vessel anatomy. Feature tracking echocardiography has recently emerged as a tool for assessment of regional and global left ventricular function. We aimed to explore the applicability of echocardiographic strain on CCTA cine clips and assess whether global and regional strain parameters are associated with the extent of coronary stenosis.</div></div><div><h3>Methods</h3><div>CCTA studies of 61 consecutive patients were reconstructed to yield cine images in classic echocardiographic long and short views. Siemens Velocity Vector Imaging (VVI) software was applied to generate strain and displacement results. Volumetric and mechanics parameters were compared among patients with no or non-significant coronary artery disease (CAD) and patients with significant CAD. Finally, a comparison of the degree of coronary stenosis to regional segmental strain was performed.</div></div><div><h3>Results</h3><div>Myocardial mechanics parameters could be generated in 60 cases. Ejection fraction (EF) and left ventricular end diastolic volume (LVEDV) were within the normal range in both groups. VVI values were lower in the CAD group (VVI LVEF 59 ± 6 vs. 50 ± 11, p = 0.0002). Global longitudinal and global circumferential strain both were significantly lower in this group. Regional segmental strain was lower in segments affected by coronary stenosis in comparison to unaffected segments.</div></div><div><h3>Conclusion</h3><div>While CT segmentation derived LVEF did not differ among groups, patients with significant coronary stenosis had reduced longitudinal and circumferential contraction. This suggests that application of VVI to CCTA cine clips tracking may help to differentiate significant and non-significant coronary stenosis, adding functional value to anatomic findings in CCTA.</div></div>\",\"PeriodicalId\":38026,\"journal\":{\"name\":\"IJC Heart and Vasculature\",\"volume\":\"56 \",\"pages\":\"Article 101586\"},\"PeriodicalIF\":2.5000,\"publicationDate\":\"2025-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11742848/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IJC Heart and Vasculature\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2352906724002525\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IJC Heart and Vasculature","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2352906724002525","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
Functional myocardial assessment in cine cardiac computerized tomographic angiography using echocardiographic feature-tracking software in patients with and without significant coronary disease
Introduction
Cardiac computerized tomographic angiography (CCTA) is perceived as a non-invasive tool for assessment of coronary vessel anatomy. Feature tracking echocardiography has recently emerged as a tool for assessment of regional and global left ventricular function. We aimed to explore the applicability of echocardiographic strain on CCTA cine clips and assess whether global and regional strain parameters are associated with the extent of coronary stenosis.
Methods
CCTA studies of 61 consecutive patients were reconstructed to yield cine images in classic echocardiographic long and short views. Siemens Velocity Vector Imaging (VVI) software was applied to generate strain and displacement results. Volumetric and mechanics parameters were compared among patients with no or non-significant coronary artery disease (CAD) and patients with significant CAD. Finally, a comparison of the degree of coronary stenosis to regional segmental strain was performed.
Results
Myocardial mechanics parameters could be generated in 60 cases. Ejection fraction (EF) and left ventricular end diastolic volume (LVEDV) were within the normal range in both groups. VVI values were lower in the CAD group (VVI LVEF 59 ± 6 vs. 50 ± 11, p = 0.0002). Global longitudinal and global circumferential strain both were significantly lower in this group. Regional segmental strain was lower in segments affected by coronary stenosis in comparison to unaffected segments.
Conclusion
While CT segmentation derived LVEF did not differ among groups, patients with significant coronary stenosis had reduced longitudinal and circumferential contraction. This suggests that application of VVI to CCTA cine clips tracking may help to differentiate significant and non-significant coronary stenosis, adding functional value to anatomic findings in CCTA.
期刊介绍:
IJC Heart & Vasculature is an online-only, open-access journal dedicated to publishing original articles and reviews (also Editorials and Letters to the Editor) which report on structural and functional cardiovascular pathology, with an emphasis on imaging and disease pathophysiology. Articles must be authentic, educational, clinically relevant, and original in their content and scientific approach. IJC Heart & Vasculature requires the highest standards of scientific integrity in order to promote reliable, reproducible and verifiable research findings. All authors are advised to consult the Principles of Ethical Publishing in the International Journal of Cardiology before submitting a manuscript. Submission of a manuscript to this journal gives the publisher the right to publish that paper if it is accepted. Manuscripts may be edited to improve clarity and expression.