{"title":"研究分段总和生物测量法对现代短眼眼内透镜功率计算公式的附加作用。","authors":"Hany Ahmed Helaly, Mohamed Hassan Elkhawaga, Mohamed Sobhy El-Mansy, Mohamed Sobhy Hassan","doi":"10.1186/s12886-025-03896-1","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To study the added effect of sum-of-segments (SOS) biometry to modern intraocular lens power calculation formulas for eyes with short axial length.</p><p><strong>Methods: </strong>This was a retrospective case series that included 99 eyes from 99 patients. Preoperative AXL measurements were conducted utilizing the ARGOS biometer (Alcon, Inc., Fort Worth, TX). The following formulas were used: Barrett Universal II (BUII), Cooke K6, EVO 2.0, and PEARL-DGS formulas. Additionally, the Barrett formula has been updated and is now incorporated into the ARGOS biometer, introducing the Barrett true axial length (BTAL) formula.</p><p><strong>Results: </strong>EVO 2.0<sub>sos</sub> and PEARL-DGS<sub>sos</sub> formulas had the highest cases within ± 0.25 D of the intended refraction (45.45% and 42.42%, respectively). The PEARL-DGS<sub>sos</sub> was the only formula to show a myopic mean prediction error (-0.25 ± 0.36 D). The Cooke K6 formula showed the highest hyperopic mean prediction error (0.55 ± 0.35 D), followed by EVO 2.0, Cooke K6<sub>sos</sub>, and BUII formulas. BTAL had mean prediction error of 0.15 ± 0.47 which is less hyperopic than BUII (0.43 ± 0.39 D). Subgroup analysis of eyes with AXL 21 mm or shorter (n = 57) was done. Again, the PEARL-DGS<sub>sos</sub> formula showed the only myopic mean prediction error (-0.23 ± 0.37 D).</p><p><strong>Conclusion: </strong>PEARL-DGS<sub>sos</sub> was the only formula to show a myopic mean prediction error. Using BTAL and SOS option in Cooke K6, EVO 2.0, and PEARL-DGS formulas decreased the undesirable hyperopic shift in the mean prediction error. This effect was more evident in shorter eyes ≤ 21.0 mm.</p>","PeriodicalId":9058,"journal":{"name":"BMC Ophthalmology","volume":"25 1","pages":"63"},"PeriodicalIF":1.7000,"publicationDate":"2025-02-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11816771/pdf/","citationCount":"0","resultStr":"{\"title\":\"Studying the added effect of sum-of-segments biometry to modern intraocular lens power calculation formulas for short eyes.\",\"authors\":\"Hany Ahmed Helaly, Mohamed Hassan Elkhawaga, Mohamed Sobhy El-Mansy, Mohamed Sobhy Hassan\",\"doi\":\"10.1186/s12886-025-03896-1\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To study the added effect of sum-of-segments (SOS) biometry to modern intraocular lens power calculation formulas for eyes with short axial length.</p><p><strong>Methods: </strong>This was a retrospective case series that included 99 eyes from 99 patients. Preoperative AXL measurements were conducted utilizing the ARGOS biometer (Alcon, Inc., Fort Worth, TX). The following formulas were used: Barrett Universal II (BUII), Cooke K6, EVO 2.0, and PEARL-DGS formulas. Additionally, the Barrett formula has been updated and is now incorporated into the ARGOS biometer, introducing the Barrett true axial length (BTAL) formula.</p><p><strong>Results: </strong>EVO 2.0<sub>sos</sub> and PEARL-DGS<sub>sos</sub> formulas had the highest cases within ± 0.25 D of the intended refraction (45.45% and 42.42%, respectively). The PEARL-DGS<sub>sos</sub> was the only formula to show a myopic mean prediction error (-0.25 ± 0.36 D). The Cooke K6 formula showed the highest hyperopic mean prediction error (0.55 ± 0.35 D), followed by EVO 2.0, Cooke K6<sub>sos</sub>, and BUII formulas. BTAL had mean prediction error of 0.15 ± 0.47 which is less hyperopic than BUII (0.43 ± 0.39 D). Subgroup analysis of eyes with AXL 21 mm or shorter (n = 57) was done. Again, the PEARL-DGS<sub>sos</sub> formula showed the only myopic mean prediction error (-0.23 ± 0.37 D).</p><p><strong>Conclusion: </strong>PEARL-DGS<sub>sos</sub> was the only formula to show a myopic mean prediction error. Using BTAL and SOS option in Cooke K6, EVO 2.0, and PEARL-DGS formulas decreased the undesirable hyperopic shift in the mean prediction error. This effect was more evident in shorter eyes ≤ 21.0 mm.</p>\",\"PeriodicalId\":9058,\"journal\":{\"name\":\"BMC Ophthalmology\",\"volume\":\"25 1\",\"pages\":\"63\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2025-02-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11816771/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"BMC Ophthalmology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1186/s12886-025-03896-1\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12886-025-03896-1","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:研究短眼轴长人工晶状体度数计算公式中分段和(sum-of-segments, SOS)生物计量的补充作用。方法:这是一个回顾性病例系列,包括99例患者的99只眼睛。术前AXL测量采用ARGOS生物计(Alcon, Inc., Fort Worth, TX)。使用以下配方:Barrett Universal II (BUII)、Cooke K6、EVO 2.0、PEARL-DGS配方。此外,巴雷特公式已经更新,现在纳入ARGOS生物计,引入巴雷特真轴长(BTAL)公式。结果:EVO 2.0sos和PEARL-DGSsos配方在预期屈光度±0.25 D范围内的发生率最高,分别为45.45%和42.42%。PEARL-DGSsos是唯一的近视平均预测误差(-0.25±0.36 D)的公式,Cooke K6公式的远视平均预测误差最大(0.55±0.35 D),其次是EVO 2.0、Cooke K6sos和BUII公式。BTAL的平均预测误差为0.15±0.47,低于BUII的平均预测误差(0.43±0.39 D)。对AXL≤21 mm的眼(n = 57)进行亚组分析。结论:PEARL-DGSsos公式是唯一出现近视平均预测误差的公式(-0.23±0.37 D)。在Cooke K6、EVO 2.0和PEARL-DGS公式中使用BTAL和SOS选项减少了平均预测误差的不良远视偏移。这种效果在≤21.0 mm的短眼中更为明显。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Studying the added effect of sum-of-segments biometry to modern intraocular lens power calculation formulas for short eyes.

Purpose: To study the added effect of sum-of-segments (SOS) biometry to modern intraocular lens power calculation formulas for eyes with short axial length.

Methods: This was a retrospective case series that included 99 eyes from 99 patients. Preoperative AXL measurements were conducted utilizing the ARGOS biometer (Alcon, Inc., Fort Worth, TX). The following formulas were used: Barrett Universal II (BUII), Cooke K6, EVO 2.0, and PEARL-DGS formulas. Additionally, the Barrett formula has been updated and is now incorporated into the ARGOS biometer, introducing the Barrett true axial length (BTAL) formula.

Results: EVO 2.0sos and PEARL-DGSsos formulas had the highest cases within ± 0.25 D of the intended refraction (45.45% and 42.42%, respectively). The PEARL-DGSsos was the only formula to show a myopic mean prediction error (-0.25 ± 0.36 D). The Cooke K6 formula showed the highest hyperopic mean prediction error (0.55 ± 0.35 D), followed by EVO 2.0, Cooke K6sos, and BUII formulas. BTAL had mean prediction error of 0.15 ± 0.47 which is less hyperopic than BUII (0.43 ± 0.39 D). Subgroup analysis of eyes with AXL 21 mm or shorter (n = 57) was done. Again, the PEARL-DGSsos formula showed the only myopic mean prediction error (-0.23 ± 0.37 D).

Conclusion: PEARL-DGSsos was the only formula to show a myopic mean prediction error. Using BTAL and SOS option in Cooke K6, EVO 2.0, and PEARL-DGS formulas decreased the undesirable hyperopic shift in the mean prediction error. This effect was more evident in shorter eyes ≤ 21.0 mm.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
BMC Ophthalmology
BMC Ophthalmology OPHTHALMOLOGY-
CiteScore
3.40
自引率
5.00%
发文量
441
审稿时长
6-12 weeks
期刊介绍: BMC Ophthalmology is an open access, peer-reviewed journal that considers articles on all aspects of the prevention, diagnosis and management of eye disorders, as well as related molecular genetics, pathophysiology, and epidemiology.
期刊最新文献
hsa_circ_0068631 facilitates the progression of diabetic retinopathy via regulating miR-140-5p in retinal microvascular endothelial cells. Analysis of macular microvasculature changes in human immunodeficiency virus infection using swept-source OCT angiography. Efficacy and safety of low-concentration atropine combined with orthokeratology for children with myopia: a systematic review and meta-analysis of randomized controlled trials. Visual function and cerebrospinal fluid volume along the optic nerve in patients with spontaneous cerebrospinal fluid rhinorrhea: a cross-sectional study. Combined anti-VEGF approach in neovascular glaucoma: clinical outcomes of intracameral and intravitreal bevacizumab administration.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1