{"title":"使用1050赫兹准分子激光和七维眼动仪治疗近视散光的效果。","authors":"Ae Ra Kee, Muhammad Amir Bin Ismail, Han-Bor Fam, Johnson Choon-Hwai Tan, Alex Koon Hin Lau, Wee-Jin Heng","doi":"10.3928/1081597X-20250130-01","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the efficacy, predictability, and safety of laser in situ keratomileusis (LASIK) for the correction of myopia and myopic astigmatism using the SCHWIND Amaris 1050RS excimer laser (SCHWIND eye-tech-solutions).</p><p><strong>Methods: </strong>This was a prospective cohort study of 1,420 eyes with myopia or myopic astigmatism that underwent LASIK in a single tertiary center between January 2017 and April 2022. The IntraLase iFS femtosecond laser (Johnson & Johnson Vision) was used for flap creation and excimer laser ablation was performed using the SCHWIND Amaris 1050RS with aspheric aberration-free ablation profile, asymmetric pupillary offset, and seven-dimensional eye tracking. Preoperative mean spherical equivalent was -5.81 ± 2.41 diopters (D) (range: -0.63 to -13.63 D).</p><p><strong>Results: </strong>At 3 months, 95.1% and 99.6% of eyes achieved uncorrected distance visual acuity of 20/20 and 20/40 or better, respectively. The mean efficacy index was 0.99 ± 0.06 and the mean safety index was 1.0 ± 0.02. For predictability, 97.7% and 99.7% of eyes were within ±0.50 and ±1.00 D of the intended correction, respectively. The mean postoperative spherical equivalent was +0.02 ± 0.21 D, mean cylinder was 0.13 ± 0.25 D, mean vector-analyzed magnitude of cylindrical error was 0.09 ± 0.22 D, mean cylindrical angle of error was 0.64 ± 6.79 degrees, and mean cylindrical vector difference was 0.15 ± 0.26 D. None had significant surgical complications.</p><p><strong>Conclusions: </strong>This study demonstrates excellent efficacy, predictability, and safety of the SCHWIND Amaris 1050RS excimer laser for the correction of myopic astigmatism. The seven-dimensional eye tracker was effective in compensating for eye movements intraoperatively. <b>[<i>J Refract Surg</i>. 2025;41(3):e231-e237.]</b>.</p>","PeriodicalId":16951,"journal":{"name":"Journal of refractive surgery","volume":"41 3","pages":"e231-e237"},"PeriodicalIF":3.0000,"publicationDate":"2025-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Outcomes of LASIK for Myopic Astigmatism Using a 1,050-Hz Excimer Laser and Seven-Dimensional Eye Tracker.\",\"authors\":\"Ae Ra Kee, Muhammad Amir Bin Ismail, Han-Bor Fam, Johnson Choon-Hwai Tan, Alex Koon Hin Lau, Wee-Jin Heng\",\"doi\":\"10.3928/1081597X-20250130-01\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To evaluate the efficacy, predictability, and safety of laser in situ keratomileusis (LASIK) for the correction of myopia and myopic astigmatism using the SCHWIND Amaris 1050RS excimer laser (SCHWIND eye-tech-solutions).</p><p><strong>Methods: </strong>This was a prospective cohort study of 1,420 eyes with myopia or myopic astigmatism that underwent LASIK in a single tertiary center between January 2017 and April 2022. The IntraLase iFS femtosecond laser (Johnson & Johnson Vision) was used for flap creation and excimer laser ablation was performed using the SCHWIND Amaris 1050RS with aspheric aberration-free ablation profile, asymmetric pupillary offset, and seven-dimensional eye tracking. Preoperative mean spherical equivalent was -5.81 ± 2.41 diopters (D) (range: -0.63 to -13.63 D).</p><p><strong>Results: </strong>At 3 months, 95.1% and 99.6% of eyes achieved uncorrected distance visual acuity of 20/20 and 20/40 or better, respectively. The mean efficacy index was 0.99 ± 0.06 and the mean safety index was 1.0 ± 0.02. For predictability, 97.7% and 99.7% of eyes were within ±0.50 and ±1.00 D of the intended correction, respectively. The mean postoperative spherical equivalent was +0.02 ± 0.21 D, mean cylinder was 0.13 ± 0.25 D, mean vector-analyzed magnitude of cylindrical error was 0.09 ± 0.22 D, mean cylindrical angle of error was 0.64 ± 6.79 degrees, and mean cylindrical vector difference was 0.15 ± 0.26 D. None had significant surgical complications.</p><p><strong>Conclusions: </strong>This study demonstrates excellent efficacy, predictability, and safety of the SCHWIND Amaris 1050RS excimer laser for the correction of myopic astigmatism. The seven-dimensional eye tracker was effective in compensating for eye movements intraoperatively. <b>[<i>J Refract Surg</i>. 2025;41(3):e231-e237.]</b>.</p>\",\"PeriodicalId\":16951,\"journal\":{\"name\":\"Journal of refractive surgery\",\"volume\":\"41 3\",\"pages\":\"e231-e237\"},\"PeriodicalIF\":3.0000,\"publicationDate\":\"2025-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of refractive surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3928/1081597X-20250130-01\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of refractive surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3928/1081597X-20250130-01","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:评价SCHWIND Amaris 1050RS准分子激光(SCHWIND眼科技术解决方案)原位角膜磨圆术(LASIK)矫正近视和近视散光的疗效、可预测性和安全性。方法:这是一项前瞻性队列研究,纳入了2017年1月至2022年4月在单一三级中心接受LASIK手术的1420只近视或近视散光眼睛。使用IntraLase iFS飞秒激光(Johnson & Johnson Vision)进行皮瓣创建,使用SCHWIND Amaris 1050RS进行准分子激光消融,具有无非球面像差消融轮廓,不对称瞳孔偏移和七维眼动追踪。术前平均球等效度为-5.81±2.41屈光度(D)(范围:-0.63至-13.63 D)。结果:3个月时,95.1%和99.6%的眼睛达到20/20和20/40以上的非矫正距离视力。平均疗效指数为0.99±0.06,平均安全指数为1.0±0.02。对于可预测性,97.7%和99.7%的眼睛分别在预期矫正的±0.50和±1.00 D范围内。术后平均球面等效为+0.02±0.21 D,平均柱面为0.13±0.25 D,平均矢量分析柱面误差幅度为0.09±0.22 D,平均柱面误差角为0.64±6.79度,平均柱面矢量差为0.15±0.26 D,无明显手术并发症。结论:本研究证明了SCHWIND Amaris 1050RS准分子激光矫正近视散光的良好疗效、可预测性和安全性。七维眼动仪可有效补偿术中眼球运动。[J].中华眼科杂志,2015;41(3):391 - 391。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Outcomes of LASIK for Myopic Astigmatism Using a 1,050-Hz Excimer Laser and Seven-Dimensional Eye Tracker.

Purpose: To evaluate the efficacy, predictability, and safety of laser in situ keratomileusis (LASIK) for the correction of myopia and myopic astigmatism using the SCHWIND Amaris 1050RS excimer laser (SCHWIND eye-tech-solutions).

Methods: This was a prospective cohort study of 1,420 eyes with myopia or myopic astigmatism that underwent LASIK in a single tertiary center between January 2017 and April 2022. The IntraLase iFS femtosecond laser (Johnson & Johnson Vision) was used for flap creation and excimer laser ablation was performed using the SCHWIND Amaris 1050RS with aspheric aberration-free ablation profile, asymmetric pupillary offset, and seven-dimensional eye tracking. Preoperative mean spherical equivalent was -5.81 ± 2.41 diopters (D) (range: -0.63 to -13.63 D).

Results: At 3 months, 95.1% and 99.6% of eyes achieved uncorrected distance visual acuity of 20/20 and 20/40 or better, respectively. The mean efficacy index was 0.99 ± 0.06 and the mean safety index was 1.0 ± 0.02. For predictability, 97.7% and 99.7% of eyes were within ±0.50 and ±1.00 D of the intended correction, respectively. The mean postoperative spherical equivalent was +0.02 ± 0.21 D, mean cylinder was 0.13 ± 0.25 D, mean vector-analyzed magnitude of cylindrical error was 0.09 ± 0.22 D, mean cylindrical angle of error was 0.64 ± 6.79 degrees, and mean cylindrical vector difference was 0.15 ± 0.26 D. None had significant surgical complications.

Conclusions: This study demonstrates excellent efficacy, predictability, and safety of the SCHWIND Amaris 1050RS excimer laser for the correction of myopic astigmatism. The seven-dimensional eye tracker was effective in compensating for eye movements intraoperatively. [J Refract Surg. 2025;41(3):e231-e237.].

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
5.10
自引率
12.50%
发文量
160
审稿时长
4-8 weeks
期刊介绍: The Journal of Refractive Surgery, the official journal of the International Society of Refractive Surgery, a partner of the American Academy of Ophthalmology, has been a monthly peer-reviewed forum for original research, review, and evaluation of refractive and lens-based surgical procedures for more than 30 years. Practical, clinically valuable articles provide readers with the most up-to-date information regarding advances in the field of refractive surgery. Begin to explore the Journal and all of its great benefits such as: • Columns including “Translational Science,” “Surgical Techniques,” and “Biomechanics” • Supplemental videos and materials available for many articles • Access to current articles, as well as several years of archived content • Articles posted online just 2 months after acceptance.
期刊最新文献
Visual Outcomes and the Impact of Intermediate Segment Orientation on the Performance of an Asymmetric Multifocal Intraocular Lens. The Use of Digital Integrated Manifest Refraction in Pseudophakic Eyes. Rotational Stability and Vault Outcomes of the EVO ICL Using Oblique Implanting Orientation Compared to Horizontal/Vertical Implanting Orientation. Corneal Endothelium and Tear Film Metrics Enhance the Accuracy of Machine Learning Prediction in Implantable Collamer Lens Surgery Outcomes. Clarification Regarding Astigmatism Inclusion Criteria in a Study Comparing TG-LASIK and KLEx.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1