{"title":"射线照相图像的远程传输。初步报告。","authors":"U Nilsson, U Nyman, M Nilsson","doi":"10.1177/028418518602700318","DOIUrl":null,"url":null,"abstract":"<p><p>A digital system for transmission of images over telephone lines using a 256 X 256 X 6 bits matrix provided for communication between a county hospital and a university hospital is presented. During a three-month period radiologic diagnostic problems encountered in 62 patients (computed tomography in 46 and conventional radiography in 16) were referred by transmitting selected images from each examination. Transmission of computed tomograms was performed without significant degradation of image quality and there was no loss of diagnostic information. Deterioration of image quality was noticed when conventional films especially those of the chest, were digitized and transmitted, though in no instance were they non-diagnostic. The consultations gave valuable information to the transmitting radiologist in approximately 50 per cent of the cases. Review by the consulted radiologists of all original films in each of the examinations 6 months later did not improve the diagnostic results. Thus, a few carefully selected images, digitized and transmitted over telephone lines, may be sufficient for adequate consultation.</p>","PeriodicalId":7142,"journal":{"name":"Acta radiologica: diagnosis","volume":"27 3","pages":"357-60"},"PeriodicalIF":0.0000,"publicationDate":"1986-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1177/028418518602700318","citationCount":"8","resultStr":"{\"title\":\"Teletransmission of radiographic images. Preliminary report.\",\"authors\":\"U Nilsson, U Nyman, M Nilsson\",\"doi\":\"10.1177/028418518602700318\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A digital system for transmission of images over telephone lines using a 256 X 256 X 6 bits matrix provided for communication between a county hospital and a university hospital is presented. During a three-month period radiologic diagnostic problems encountered in 62 patients (computed tomography in 46 and conventional radiography in 16) were referred by transmitting selected images from each examination. Transmission of computed tomograms was performed without significant degradation of image quality and there was no loss of diagnostic information. Deterioration of image quality was noticed when conventional films especially those of the chest, were digitized and transmitted, though in no instance were they non-diagnostic. The consultations gave valuable information to the transmitting radiologist in approximately 50 per cent of the cases. Review by the consulted radiologists of all original films in each of the examinations 6 months later did not improve the diagnostic results. Thus, a few carefully selected images, digitized and transmitted over telephone lines, may be sufficient for adequate consultation.</p>\",\"PeriodicalId\":7142,\"journal\":{\"name\":\"Acta radiologica: diagnosis\",\"volume\":\"27 3\",\"pages\":\"357-60\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1986-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1177/028418518602700318\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta radiologica: diagnosis\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1177/028418518602700318\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta radiologica: diagnosis","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/028418518602700318","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8
摘要
介绍了一种用于县级医院和大学医院之间通信的使用256 X 256 X 6位矩阵的电话线图像传输数字系统。在三个月的时间里,62例患者遇到的放射诊断问题(46例计算机断层扫描和16例常规放射照相)通过传输每次检查的选定图像进行参考。计算机断层图像的传输没有明显的图像质量下降,也没有诊断信息的损失。当传统影像,尤其是胸部影像,被数字化并传输时,图像质量会下降,尽管在任何情况下都是非诊断性的。在大约50%的病例中,会诊向放射科医生提供了宝贵的资料。6个月后,会诊放射科医师对每次检查的所有原始片子进行复查,诊断结果没有改善。因此,一些经过精心挑选的图像,经过数字化并通过电话线传送,可能就足以进行充分的磋商。
Teletransmission of radiographic images. Preliminary report.
A digital system for transmission of images over telephone lines using a 256 X 256 X 6 bits matrix provided for communication between a county hospital and a university hospital is presented. During a three-month period radiologic diagnostic problems encountered in 62 patients (computed tomography in 46 and conventional radiography in 16) were referred by transmitting selected images from each examination. Transmission of computed tomograms was performed without significant degradation of image quality and there was no loss of diagnostic information. Deterioration of image quality was noticed when conventional films especially those of the chest, were digitized and transmitted, though in no instance were they non-diagnostic. The consultations gave valuable information to the transmitting radiologist in approximately 50 per cent of the cases. Review by the consulted radiologists of all original films in each of the examinations 6 months later did not improve the diagnostic results. Thus, a few carefully selected images, digitized and transmitted over telephone lines, may be sufficient for adequate consultation.