调和生物乙醇的pHe测量:缓冲50- 50% wt%水-乙醇混合物的pHabs测量

IF 2.5 Q1 Chemistry Analytica Chimica Acta: X Pub Date : 2022-03-01 DOI:10.1016/j.acax.2022.100085
L. Deleebeeck , A. Snedden , D. Stoica
{"title":"调和生物乙醇的pHe测量:缓冲50- 50% wt%水-乙醇混合物的pHabs测量","authors":"L. Deleebeeck ,&nbsp;A. Snedden ,&nbsp;D. Stoica","doi":"10.1016/j.acax.2022.100085","DOIUrl":null,"url":null,"abstract":"<div><p>Water-ethanol mixtures intended for specific purposes, such as bioethanol fuel, can be subject to national quality standards, including the measurement of pHe – a solvent-specific quantification of acidity. This work discusses the shortcomings of the use of pHe in these quality standards, including the lack of metrological traceability of pHe measurements made using combination pH electrodes calibrated using aqueous pH buffers. The feasibility of measuring the acidity of 50-50 wt% water-ethanol mixtures on a non-solvent-specific, unified pH scale, which is traceable to the conventional aqueous pH scale (<span><math><mrow><msubsup><mtext>pH</mtext><mtext>abs</mtext><mrow><msub><mtext>H</mtext><mn>2</mn></msub><mtext>O</mtext></mrow></msubsup></mrow></math></span>) is demonstrated. <span><math><mrow><msubsup><mtext>pH</mtext><mtext>abs</mtext><mrow><msub><mtext>H</mtext><mn>2</mn></msub><mtext>O</mtext></mrow></msubsup></mrow></math></span> measurements of buffered and un-buffered water-ethanol mixtures using two cell configurations, including the use of an ionic liquid salt bridge (ILSB), show good agreement. The cell configuration, consisting of a commercial glass (half-cell) electrode and a reference electrode incorporating an ILSB, can be readily adopted by measurement laboratories.</p></div>","PeriodicalId":241,"journal":{"name":"Analytica Chimica Acta: X","volume":"10 ","pages":"Article 100085"},"PeriodicalIF":2.5000,"publicationDate":"2022-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9240372/pdf/","citationCount":"1","resultStr":"{\"title\":\"Reconciling the pHe measurements of bioethanol: pHabs measurements of buffered 50-50 wt% water-ethanol mixtures\",\"authors\":\"L. Deleebeeck ,&nbsp;A. Snedden ,&nbsp;D. Stoica\",\"doi\":\"10.1016/j.acax.2022.100085\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Water-ethanol mixtures intended for specific purposes, such as bioethanol fuel, can be subject to national quality standards, including the measurement of pHe – a solvent-specific quantification of acidity. This work discusses the shortcomings of the use of pHe in these quality standards, including the lack of metrological traceability of pHe measurements made using combination pH electrodes calibrated using aqueous pH buffers. The feasibility of measuring the acidity of 50-50 wt% water-ethanol mixtures on a non-solvent-specific, unified pH scale, which is traceable to the conventional aqueous pH scale (<span><math><mrow><msubsup><mtext>pH</mtext><mtext>abs</mtext><mrow><msub><mtext>H</mtext><mn>2</mn></msub><mtext>O</mtext></mrow></msubsup></mrow></math></span>) is demonstrated. <span><math><mrow><msubsup><mtext>pH</mtext><mtext>abs</mtext><mrow><msub><mtext>H</mtext><mn>2</mn></msub><mtext>O</mtext></mrow></msubsup></mrow></math></span> measurements of buffered and un-buffered water-ethanol mixtures using two cell configurations, including the use of an ionic liquid salt bridge (ILSB), show good agreement. The cell configuration, consisting of a commercial glass (half-cell) electrode and a reference electrode incorporating an ILSB, can be readily adopted by measurement laboratories.</p></div>\",\"PeriodicalId\":241,\"journal\":{\"name\":\"Analytica Chimica Acta: X\",\"volume\":\"10 \",\"pages\":\"Article 100085\"},\"PeriodicalIF\":2.5000,\"publicationDate\":\"2022-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9240372/pdf/\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Analytica Chimica Acta: X\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2590134622000019\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"Chemistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytica Chimica Acta: X","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2590134622000019","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Chemistry","Score":null,"Total":0}
引用次数: 1

摘要

用于特定用途的水-乙醇混合物,如生物乙醇燃料,可以遵守国家质量标准,包括pHe的测量-一种溶剂特定的酸度量化。这项工作讨论了在这些质量标准中使用pHe的缺点,包括使用使用水性pH缓冲液校准的组合pH电极进行的pHe测量缺乏计量可追溯性。证明了在非溶剂特定的统一pH标度上测量50-50 wt%水-乙醇混合物酸度的可行性,该pH标度可追溯到传统的水pH标度(pHabsH2O)。使用两种电池配置,包括使用离子液体盐桥(ILSB),对缓冲和非缓冲水-乙醇混合物的pHabsH2O测量显示出良好的一致性。该电池配置由商用玻璃(半电池)电极和包含ILSB的参比电极组成,可以很容易地被测量实验室采用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Reconciling the pHe measurements of bioethanol: pHabs measurements of buffered 50-50 wt% water-ethanol mixtures

Water-ethanol mixtures intended for specific purposes, such as bioethanol fuel, can be subject to national quality standards, including the measurement of pHe – a solvent-specific quantification of acidity. This work discusses the shortcomings of the use of pHe in these quality standards, including the lack of metrological traceability of pHe measurements made using combination pH electrodes calibrated using aqueous pH buffers. The feasibility of measuring the acidity of 50-50 wt% water-ethanol mixtures on a non-solvent-specific, unified pH scale, which is traceable to the conventional aqueous pH scale (pHabsH2O) is demonstrated. pHabsH2O measurements of buffered and un-buffered water-ethanol mixtures using two cell configurations, including the use of an ionic liquid salt bridge (ILSB), show good agreement. The cell configuration, consisting of a commercial glass (half-cell) electrode and a reference electrode incorporating an ILSB, can be readily adopted by measurement laboratories.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Analytica Chimica Acta: X
Analytica Chimica Acta: X Chemistry-Analytical Chemistry
自引率
0.00%
发文量
3
审稿时长
16 weeks
期刊最新文献
Editorial Board Outside Front Cover Reconciling the pHe measurements of bioethanol: pHabs measurements of buffered 50-50 wt% water-ethanol mixtures Outside Front Cover Editorial Board
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1