R Bartl, F Hofer
{"title":"[采用固定平行孔导向装置置入防旋转螺钉治疗髋部股关节旁骨折]。","authors":"R Bartl, F Hofer","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>We implanted in case of hip-near fractures of the femur after DHS the anti-rotation screw with help of a special parallel drill guide. It was possible to position the anti-rotation screw in a parallel fashion in all patients so that the dynamic effect of the DHS was not impaired and a faulty penetration of the screw into the hip by a badly positioned anti-rotation screw could be avoided. The radiological follow up shows us no sign of impaired healing.</p>","PeriodicalId":29789,"journal":{"name":"Unfallchirurgie","volume":"22 2","pages":"85-7"},"PeriodicalIF":0.6000,"publicationDate":"1996-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Placement of anti-rotation screw using a fixed parallel bore guide device in dynamic hip screw management of hip para-articular femoral fractures].\",\"authors\":\"R Bartl, F Hofer\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>We implanted in case of hip-near fractures of the femur after DHS the anti-rotation screw with help of a special parallel drill guide. It was possible to position the anti-rotation screw in a parallel fashion in all patients so that the dynamic effect of the DHS was not impaired and a faulty penetration of the screw into the hip by a badly positioned anti-rotation screw could be avoided. The radiological follow up shows us no sign of impaired healing.</p>\",\"PeriodicalId\":29789,\"journal\":{\"name\":\"Unfallchirurgie\",\"volume\":\"22 2\",\"pages\":\"85-7\"},\"PeriodicalIF\":0.6000,\"publicationDate\":\"1996-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Unfallchirurgie\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"EMERGENCY MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Unfallchirurgie","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"EMERGENCY MEDICINE","Score":null,"Total":0}
[Placement of anti-rotation screw using a fixed parallel bore guide device in dynamic hip screw management of hip para-articular femoral fractures].
We implanted in case of hip-near fractures of the femur after DHS the anti-rotation screw with help of a special parallel drill guide. It was possible to position the anti-rotation screw in a parallel fashion in all patients so that the dynamic effect of the DHS was not impaired and a faulty penetration of the screw into the hip by a badly positioned anti-rotation screw could be avoided. The radiological follow up shows us no sign of impaired healing.