感音神经性听力损失的听者对阻尼助听器和无阻尼助听器的偏好和表现。

L A Davis, S A Davidson
{"title":"感音神经性听力损失的听者对阻尼助听器和无阻尼助听器的偏好和表现。","authors":"L A Davis,&nbsp;S A Davidson","doi":"10.1044/jshr.3903.483","DOIUrl":null,"url":null,"abstract":"<p><p>This study investigated the relationship between acoustic damping of hearing aid responses and listeners' speech discrimination and judgments of preference and sound quality. Eighteen subjects with essentially equivalent hearing impairments participated. Subjects' speech discrimination was evaluated for a male talker in quiet and in noise and for a female talker in the same conditions with hearing aids with 0 dB, -5 dB, and -10 dB of damping. Subjects also compared the damping levels using eight bipolar adjective pairs and provided judgments of overall preference. Measurements of the hearing aid responses were made in a 2-cm3 coupler and in the subjects' ears using probe microphone techniques. Smoothness of the responses was quantified using the Index of Response Irregularity (IRI) and the Frequency Response Smoothness Quantification Index (FReSQI). Subjects preferred the two damped hearing aid responses to the undamped. They also had better speech discrimination with damped hearing aid responses. The bipolar adjectives were of limited use in comparing hearing aids. A few questions about hearing aid sound quality and preference appear adequate for evaluating listeners' choice of hearing aids. Smoothness of the hearing aid responses in the test box was higher for the damped hearing aids than for the undamped. However, for real ear responses measured using a probe microphone, smoothness did not change as a function of damping level.</p>","PeriodicalId":76022,"journal":{"name":"Journal of speech and hearing research","volume":"39 3","pages":"483-93"},"PeriodicalIF":0.0000,"publicationDate":"1996-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1044/jshr.3903.483","citationCount":"12","resultStr":"{\"title\":\"Preference for and performance with damped and undamped hearing aids by listeners with sensorineural hearing loss.\",\"authors\":\"L A Davis,&nbsp;S A Davidson\",\"doi\":\"10.1044/jshr.3903.483\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This study investigated the relationship between acoustic damping of hearing aid responses and listeners' speech discrimination and judgments of preference and sound quality. Eighteen subjects with essentially equivalent hearing impairments participated. Subjects' speech discrimination was evaluated for a male talker in quiet and in noise and for a female talker in the same conditions with hearing aids with 0 dB, -5 dB, and -10 dB of damping. Subjects also compared the damping levels using eight bipolar adjective pairs and provided judgments of overall preference. Measurements of the hearing aid responses were made in a 2-cm3 coupler and in the subjects' ears using probe microphone techniques. Smoothness of the responses was quantified using the Index of Response Irregularity (IRI) and the Frequency Response Smoothness Quantification Index (FReSQI). Subjects preferred the two damped hearing aid responses to the undamped. They also had better speech discrimination with damped hearing aid responses. The bipolar adjectives were of limited use in comparing hearing aids. A few questions about hearing aid sound quality and preference appear adequate for evaluating listeners' choice of hearing aids. Smoothness of the hearing aid responses in the test box was higher for the damped hearing aids than for the undamped. However, for real ear responses measured using a probe microphone, smoothness did not change as a function of damping level.</p>\",\"PeriodicalId\":76022,\"journal\":{\"name\":\"Journal of speech and hearing research\",\"volume\":\"39 3\",\"pages\":\"483-93\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1996-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1044/jshr.3903.483\",\"citationCount\":\"12\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of speech and hearing research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1044/jshr.3903.483\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of speech and hearing research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1044/jshr.3903.483","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 12

摘要

本研究探讨了助听器反应的声阻尼与听者的言语辨别、偏好判断和音质之间的关系。18名听力障碍基本相同的受试者参与了研究。对安静和噪音环境下的男性说话者以及在相同条件下使用助听器的女性说话者的语音辨别能力进行了评估,助听器的阻尼分别为0 dB、-5 dB和-10 dB。受试者还使用八个双极性形容词对比较阻尼水平,并提供总体偏好判断。助听器响应的测量是在一个2-cm3的耦合器中进行的,使用探针麦克风技术在受试者的耳朵中进行。采用反应不规则指数(IRI)和频率响应平滑量化指数(FReSQI)对反应的平滑度进行量化。与无阻尼助听器相比,受试者更喜欢两种有阻尼助听器的反应。在助听器反应减弱的情况下,他们也有更好的言语辨别能力。双极性形容词在比较助听器时使用有限。关于助听器音质和偏好的几个问题似乎足以评估听者对助听器的选择。在测试箱中,有阻尼助听器的助听器响应的平稳性高于无阻尼助听器。然而,对于使用探头麦克风测量的真实耳朵响应,平滑度不会随着阻尼水平的变化而变化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Preference for and performance with damped and undamped hearing aids by listeners with sensorineural hearing loss.

This study investigated the relationship between acoustic damping of hearing aid responses and listeners' speech discrimination and judgments of preference and sound quality. Eighteen subjects with essentially equivalent hearing impairments participated. Subjects' speech discrimination was evaluated for a male talker in quiet and in noise and for a female talker in the same conditions with hearing aids with 0 dB, -5 dB, and -10 dB of damping. Subjects also compared the damping levels using eight bipolar adjective pairs and provided judgments of overall preference. Measurements of the hearing aid responses were made in a 2-cm3 coupler and in the subjects' ears using probe microphone techniques. Smoothness of the responses was quantified using the Index of Response Irregularity (IRI) and the Frequency Response Smoothness Quantification Index (FReSQI). Subjects preferred the two damped hearing aid responses to the undamped. They also had better speech discrimination with damped hearing aid responses. The bipolar adjectives were of limited use in comparing hearing aids. A few questions about hearing aid sound quality and preference appear adequate for evaluating listeners' choice of hearing aids. Smoothness of the hearing aid responses in the test box was higher for the damped hearing aids than for the undamped. However, for real ear responses measured using a probe microphone, smoothness did not change as a function of damping level.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A Rapid Laser Probing Method Facilitates the Non-invasive and Contact-free Determination of Leaf Thermal Properties. Point-light facial displays enhance comprehension of speech in noise. Establishing the validity of recovery from stuttering without formal treatment. Role of F0 and amplitude in the perception of intervocalic glottal stops. Tactile perception of spatial stimuli on the lip surface by young and older adults.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1