{"title":"Sysmex SF-3000在白细胞差异计数解释形态学标记方面的性能评价。","authors":"P C Bartels,&nbsp;M Schoorl,&nbsp;F L Willekens","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Results from the Sysmex SF-3000 automated haematology analyser are reported with special attention to leucocyte morphology flagging in pathological conditions. Results for leucocyte differential counts provided by the Sysmex SF-3000 were compared with those obtained from the Sysmex NE-8000 and a visual evaluation based on a differential count of 400 leucocytes. One hundred samples from apparently healthy subjects and 100 samples from patients with haematological abnormalities were examined. The SF-3000 yielded a rather high frequency of flagging inappropriately referring to blasts, immature granulocytes, left shift and nucleated red blood cells/platelet clumps. The presence of atypical lymphocytes was not indicated by appropriate flagging.</p>","PeriodicalId":10285,"journal":{"name":"Clinical and laboratory haematology","volume":"19 3","pages":"187-90"},"PeriodicalIF":0.0000,"publicationDate":"1997-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of Sysmex SF-3000 performance concerning interpretive morphology flagging of the leucocyte differential count.\",\"authors\":\"P C Bartels,&nbsp;M Schoorl,&nbsp;F L Willekens\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Results from the Sysmex SF-3000 automated haematology analyser are reported with special attention to leucocyte morphology flagging in pathological conditions. Results for leucocyte differential counts provided by the Sysmex SF-3000 were compared with those obtained from the Sysmex NE-8000 and a visual evaluation based on a differential count of 400 leucocytes. One hundred samples from apparently healthy subjects and 100 samples from patients with haematological abnormalities were examined. The SF-3000 yielded a rather high frequency of flagging inappropriately referring to blasts, immature granulocytes, left shift and nucleated red blood cells/platelet clumps. The presence of atypical lymphocytes was not indicated by appropriate flagging.</p>\",\"PeriodicalId\":10285,\"journal\":{\"name\":\"Clinical and laboratory haematology\",\"volume\":\"19 3\",\"pages\":\"187-90\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1997-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical and laboratory haematology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical and laboratory haematology","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

报告了Sysmex SF-3000自动血液学分析仪的结果,特别注意病理状态下的白细胞形态标记。将Sysmex SF-3000提供的白细胞差异计数结果与Sysmex NE-8000提供的结果进行比较,并根据400个白细胞的差异计数进行视觉评估。100个样本来自表面健康的受试者和100个样本来自血液系统异常的患者。SF-3000在母细胞、未成熟粒细胞、左移和有核红细胞/血小板团块方面产生了相当高的不适当标记频率。不典型淋巴细胞的存在没有适当的标记。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Evaluation of Sysmex SF-3000 performance concerning interpretive morphology flagging of the leucocyte differential count.

Results from the Sysmex SF-3000 automated haematology analyser are reported with special attention to leucocyte morphology flagging in pathological conditions. Results for leucocyte differential counts provided by the Sysmex SF-3000 were compared with those obtained from the Sysmex NE-8000 and a visual evaluation based on a differential count of 400 leucocytes. One hundred samples from apparently healthy subjects and 100 samples from patients with haematological abnormalities were examined. The SF-3000 yielded a rather high frequency of flagging inappropriately referring to blasts, immature granulocytes, left shift and nucleated red blood cells/platelet clumps. The presence of atypical lymphocytes was not indicated by appropriate flagging.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Reply to Cavill Reference values for the activated partial thromboplastin time in infants using a synthetic reagent. A case of idiopathic hypereosinophilic syndrome with hypersegmented and hypogranular eosinophils. Reference intervals for haematological parameters in urban school children and adolescents. Atlas of Blood Cell Differentiation (Interactive CD‐ROM)
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1