M H de Keijzer, B S Jakobs, R W Brandts, M T Hofs, F J Trijbels, J A Smeitink
{"title":"快速、可靠地测量儿童高血氨浓度。","authors":"M H de Keijzer, B S Jakobs, R W Brandts, M T Hofs, F J Trijbels, J A Smeitink","doi":"10.1515/cclm.1997.35.11.853","DOIUrl":null,"url":null,"abstract":"<p><p>Newborns and children may suffer from extremely high ammonia levels in their blood. We evaluated a fast, reliable micromethod, based on the Blood Ammonia Checker II (BAC II) in combination with the dilution with fresh whole blood. Comparison of the proposed method with an enzymatic method revealed a statistically significant correlation. We conclude that the dilution of patient's blood with fresh whole blood extends the measuring range of ammonia on the BAC II analyzer from 286 mumol/l to about 700 mumol/l.</p>","PeriodicalId":77119,"journal":{"name":"European journal of clinical chemistry and clinical biochemistry : journal of the Forum of European Clinical Chemistry Societies","volume":"35 11","pages":"853-4"},"PeriodicalIF":0.0000,"publicationDate":"1997-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1515/cclm.1997.35.11.853","citationCount":"4","resultStr":"{\"title\":\"Rapid and reliable measurement of highly elevated blood ammonia concentrations in children.\",\"authors\":\"M H de Keijzer, B S Jakobs, R W Brandts, M T Hofs, F J Trijbels, J A Smeitink\",\"doi\":\"10.1515/cclm.1997.35.11.853\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Newborns and children may suffer from extremely high ammonia levels in their blood. We evaluated a fast, reliable micromethod, based on the Blood Ammonia Checker II (BAC II) in combination with the dilution with fresh whole blood. Comparison of the proposed method with an enzymatic method revealed a statistically significant correlation. We conclude that the dilution of patient's blood with fresh whole blood extends the measuring range of ammonia on the BAC II analyzer from 286 mumol/l to about 700 mumol/l.</p>\",\"PeriodicalId\":77119,\"journal\":{\"name\":\"European journal of clinical chemistry and clinical biochemistry : journal of the Forum of European Clinical Chemistry Societies\",\"volume\":\"35 11\",\"pages\":\"853-4\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1997-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1515/cclm.1997.35.11.853\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European journal of clinical chemistry and clinical biochemistry : journal of the Forum of European Clinical Chemistry Societies\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1515/cclm.1997.35.11.853\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European journal of clinical chemistry and clinical biochemistry : journal of the Forum of European Clinical Chemistry Societies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1515/cclm.1997.35.11.853","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Rapid and reliable measurement of highly elevated blood ammonia concentrations in children.
Newborns and children may suffer from extremely high ammonia levels in their blood. We evaluated a fast, reliable micromethod, based on the Blood Ammonia Checker II (BAC II) in combination with the dilution with fresh whole blood. Comparison of the proposed method with an enzymatic method revealed a statistically significant correlation. We conclude that the dilution of patient's blood with fresh whole blood extends the measuring range of ammonia on the BAC II analyzer from 286 mumol/l to about 700 mumol/l.