PTCA后低分子肝素的局部和全身递送:急性结果和对多孔球囊初始临床经验的6个月随访(PILOT-study)。多孔PTCA球囊局部治疗初探。

M Oberhoff, A Baumbach, T Hermann, C Diehl, R Maier, A Athanasiadis, C Herdeg, A Bohnet, K K Haase, W Voelker, R Baildon, S Veldhof, K R Karsch
{"title":"PTCA后低分子肝素的局部和全身递送:急性结果和对多孔球囊初始临床经验的6个月随访(PILOT-study)。多孔PTCA球囊局部治疗初探。","authors":"M Oberhoff,&nbsp;A Baumbach,&nbsp;T Hermann,&nbsp;C Diehl,&nbsp;R Maier,&nbsp;A Athanasiadis,&nbsp;C Herdeg,&nbsp;A Bohnet,&nbsp;K K Haase,&nbsp;W Voelker,&nbsp;R Baildon,&nbsp;S Veldhof,&nbsp;K R Karsch","doi":"10.1002/(sici)1097-0304(199807)44:3<267::aid-ccd4>3.0.co;2-3","DOIUrl":null,"url":null,"abstract":"<p><p>The purpose of this study was to assess safety and feasibility of intracoronary delivery of reviparin using a porous balloon following percutaneous transluminal coronary angioplasty. The 2.7 mm porous balloon used in this study had 35 holes arranged in a spiral pattern. Eighteen patients (male n = 10, female n = 8, age 63 +/- 9 years) undergoing successful PTCA in coronary arteries with a vessel diameter of 2.5 to 3.0 mm determined by online QCA (LAD = 11, RCX = 3, RCA = 4) were included. They received a bolus of 7,000 anti-Xa-IU reviparin followed by local delivery of 1,500 anti-Xa-IU in 4 ml with an injection pressure of 2 atm. The patients received additionally 10500 anti-Xa-units intravenously during the following 24 hours and a daily dose of 7000 anti-Xa-units reviparin subcutaneously for the following 28 days. Angiograms were obtained before and after PTCA, directly after local delivery, at 24 hours postintervention and after 6 months. The primary success rate was 100%. Quantitative coronary angiography showed a minimum luminal diameter of 0.42 +/- 0.14 mm before PTCA, 1.87 +/- 0.45 after PTCA, 1.67 +/- 0.43 after LDD, 1.63 +/- 0.46 after 24 hours, and 1.06 +/- 0.6 after 6 months. Angiographic follow-up was obtained in all patients. No major complications occurred during the 6-month follow-up period. The angiographic restenosis rate was 28% (5/18) at follow-up. This study demonstrates safety and feasibility of local intracoronary delivery of reviparin with a porous balloon following PTCA even in smaller diameter coronary arteries.</p>","PeriodicalId":9664,"journal":{"name":"Catheterization and cardiovascular diagnosis","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1998-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/(sici)1097-0304(199807)44:3<267::aid-ccd4>3.0.co;2-3","citationCount":"8","resultStr":"{\"title\":\"Local and systemic delivery of low molecular weight heparin following PTCA: acute results and 6-month follow-up of the initial clinical experience with the porous balloon (PILOT-study). Preliminary Investigation of Local Therapy Using Porous PTCA Balloons.\",\"authors\":\"M Oberhoff,&nbsp;A Baumbach,&nbsp;T Hermann,&nbsp;C Diehl,&nbsp;R Maier,&nbsp;A Athanasiadis,&nbsp;C Herdeg,&nbsp;A Bohnet,&nbsp;K K Haase,&nbsp;W Voelker,&nbsp;R Baildon,&nbsp;S Veldhof,&nbsp;K R Karsch\",\"doi\":\"10.1002/(sici)1097-0304(199807)44:3<267::aid-ccd4>3.0.co;2-3\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The purpose of this study was to assess safety and feasibility of intracoronary delivery of reviparin using a porous balloon following percutaneous transluminal coronary angioplasty. The 2.7 mm porous balloon used in this study had 35 holes arranged in a spiral pattern. Eighteen patients (male n = 10, female n = 8, age 63 +/- 9 years) undergoing successful PTCA in coronary arteries with a vessel diameter of 2.5 to 3.0 mm determined by online QCA (LAD = 11, RCX = 3, RCA = 4) were included. They received a bolus of 7,000 anti-Xa-IU reviparin followed by local delivery of 1,500 anti-Xa-IU in 4 ml with an injection pressure of 2 atm. The patients received additionally 10500 anti-Xa-units intravenously during the following 24 hours and a daily dose of 7000 anti-Xa-units reviparin subcutaneously for the following 28 days. Angiograms were obtained before and after PTCA, directly after local delivery, at 24 hours postintervention and after 6 months. The primary success rate was 100%. Quantitative coronary angiography showed a minimum luminal diameter of 0.42 +/- 0.14 mm before PTCA, 1.87 +/- 0.45 after PTCA, 1.67 +/- 0.43 after LDD, 1.63 +/- 0.46 after 24 hours, and 1.06 +/- 0.6 after 6 months. Angiographic follow-up was obtained in all patients. No major complications occurred during the 6-month follow-up period. The angiographic restenosis rate was 28% (5/18) at follow-up. This study demonstrates safety and feasibility of local intracoronary delivery of reviparin with a porous balloon following PTCA even in smaller diameter coronary arteries.</p>\",\"PeriodicalId\":9664,\"journal\":{\"name\":\"Catheterization and cardiovascular diagnosis\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1998-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1002/(sici)1097-0304(199807)44:3<267::aid-ccd4>3.0.co;2-3\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Catheterization and cardiovascular diagnosis\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1002/(sici)1097-0304(199807)44:3<267::aid-ccd4>3.0.co;2-3\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Catheterization and cardiovascular diagnosis","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/(sici)1097-0304(199807)44:3<267::aid-ccd4>3.0.co;2-3","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

摘要

本研究的目的是评估经皮冠状动脉血管成形术后使用多孔球囊在冠状动脉内输送维甲素的安全性和可行性。本研究使用的2.7 mm多孔球囊有35个孔,呈螺旋状排列。本研究纳入18例(男10例,女8例,年龄63±9岁)经在线QCA测定冠脉直径为2.5 ~ 3.0 mm的冠状动脉PTCA成功行PTCA的患者(LAD = 11, RCX = 3, RCA = 4)。在注射压力为2atm的情况下,患者先接受7000抗xa - iu维帕林的注射,然后局部给予4ml 1500抗xa - iu。患者在接下来的24小时内静脉注射10500单位的抗xa,在接下来的28天内每天皮下注射7000单位的抗xa。分别在PTCA前后、局部分娩后、干预后24小时和6个月后进行血管造影。初次成功率为100%。定量冠脉造影显示PTCA前最小管径为0.42 +/- 0.14 mm, PTCA后为1.87 +/- 0.45 mm, LDD后为1.67 +/- 0.43 mm, 24小时后为1.63 +/- 0.46,6个月后为1.06 +/- 0.6 mm。所有患者均行血管造影随访。随访6个月,无重大并发症发生。随访时血管造影再狭窄率为28%(5/18)。本研究表明,即使在直径较小的冠状动脉中,PTCA后用多孔球囊局部冠状动脉内递送维甲素的安全性和可行性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Local and systemic delivery of low molecular weight heparin following PTCA: acute results and 6-month follow-up of the initial clinical experience with the porous balloon (PILOT-study). Preliminary Investigation of Local Therapy Using Porous PTCA Balloons.

The purpose of this study was to assess safety and feasibility of intracoronary delivery of reviparin using a porous balloon following percutaneous transluminal coronary angioplasty. The 2.7 mm porous balloon used in this study had 35 holes arranged in a spiral pattern. Eighteen patients (male n = 10, female n = 8, age 63 +/- 9 years) undergoing successful PTCA in coronary arteries with a vessel diameter of 2.5 to 3.0 mm determined by online QCA (LAD = 11, RCX = 3, RCA = 4) were included. They received a bolus of 7,000 anti-Xa-IU reviparin followed by local delivery of 1,500 anti-Xa-IU in 4 ml with an injection pressure of 2 atm. The patients received additionally 10500 anti-Xa-units intravenously during the following 24 hours and a daily dose of 7000 anti-Xa-units reviparin subcutaneously for the following 28 days. Angiograms were obtained before and after PTCA, directly after local delivery, at 24 hours postintervention and after 6 months. The primary success rate was 100%. Quantitative coronary angiography showed a minimum luminal diameter of 0.42 +/- 0.14 mm before PTCA, 1.87 +/- 0.45 after PTCA, 1.67 +/- 0.43 after LDD, 1.63 +/- 0.46 after 24 hours, and 1.06 +/- 0.6 after 6 months. Angiographic follow-up was obtained in all patients. No major complications occurred during the 6-month follow-up period. The angiographic restenosis rate was 28% (5/18) at follow-up. This study demonstrates safety and feasibility of local intracoronary delivery of reviparin with a porous balloon following PTCA even in smaller diameter coronary arteries.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Effect of basal epicardial tone on endothelium-independent coronary flow reserve measurement. Coronary stenting in the elderly: longitudinal results in a wide spectrum of patients treated with a new and more practical approach. Diabetes Atherosclerosis Intervention Study (DAIS): quantitative coronary angiographic analysis of coronary artery atherosclerosis. Determinants of rebound thrombin activity after cessation of heparin in patients undergoing coronary interventions. Percutaneous intervention: design, technique, and pharmacology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1