{"title":"支架移植破裂致主动脉肠瘘1例。","authors":"L Norgren,&nbsp;B Jernby,&nbsp;L Engellau","doi":"10.1583/1074-6218(1998)005<0269:AFCBAR>2.0.CO;2","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To report a case of aortoenteric fistula secondary to endovascular abdominal aortic aneurysm (AAA) exclusion using the Stentor bifurcated endovascular graft.</p><p><strong>Methods and results: </strong>Seventeen months after a successful endovascular AAA procedure, a male patient developed upper gastrointestinal bleeding. An aortoenteric fistula was diagnosed. At operation, the endograft fabric was found to be ruptured in an area of suture disruption between the nitinol stents. Coincidentally, a pre-existing inflammatory process might have caused adhesions between the bowel and the aortic wall, predisposing to fistula formation. The patient recovered after placement of a conventional aortic graft.</p><p><strong>Conclusions: </strong>Suture disruption between the internal support stents is a recognized complication in the first-generation Stentor device. Although the case described here is probably not typical of the consequences of this sequela, it does reinforce the need for continual periodic imaging to check for signs of graft disruption in Stentor endografts.</p>","PeriodicalId":79443,"journal":{"name":"Journal of endovascular surgery : the official journal of the International Society for Endovascular Surgery","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1998-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"90","resultStr":"{\"title\":\"Aortoenteric fistula caused by a ruptured stent-graft: a case report.\",\"authors\":\"L Norgren,&nbsp;B Jernby,&nbsp;L Engellau\",\"doi\":\"10.1583/1074-6218(1998)005<0269:AFCBAR>2.0.CO;2\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To report a case of aortoenteric fistula secondary to endovascular abdominal aortic aneurysm (AAA) exclusion using the Stentor bifurcated endovascular graft.</p><p><strong>Methods and results: </strong>Seventeen months after a successful endovascular AAA procedure, a male patient developed upper gastrointestinal bleeding. An aortoenteric fistula was diagnosed. At operation, the endograft fabric was found to be ruptured in an area of suture disruption between the nitinol stents. Coincidentally, a pre-existing inflammatory process might have caused adhesions between the bowel and the aortic wall, predisposing to fistula formation. The patient recovered after placement of a conventional aortic graft.</p><p><strong>Conclusions: </strong>Suture disruption between the internal support stents is a recognized complication in the first-generation Stentor device. Although the case described here is probably not typical of the consequences of this sequela, it does reinforce the need for continual periodic imaging to check for signs of graft disruption in Stentor endografts.</p>\",\"PeriodicalId\":79443,\"journal\":{\"name\":\"Journal of endovascular surgery : the official journal of the International Society for Endovascular Surgery\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1998-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"90\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of endovascular surgery : the official journal of the International Society for Endovascular Surgery\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1583/1074-6218(1998)005<0269:AFCBAR>2.0.CO;2\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of endovascular surgery : the official journal of the International Society for Endovascular Surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1583/1074-6218(1998)005<0269:AFCBAR>2.0.CO;2","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 90

摘要

目的:报告一例血管内支架分叉移植排除腹主动脉瘤继发主动脉肠瘘的病例。方法和结果:在血管内AAA手术成功17个月后,一名男性患者出现上消化道出血。诊断为主动脉肠瘘。在手术中,发现在镍钛诺支架之间的缝合断裂区域内移植物织物破裂。巧合的是,先前存在的炎症过程可能导致肠和主动脉壁之间的粘连,容易形成瘘管。患者在常规主动脉移植后恢复。结论:内支架之间的缝线断裂是第一代支架装置中公认的并发症。虽然这里描述的病例可能不是这种后遗症的典型后果,但它确实加强了持续定期影像学检查stenitor内移植物移植物破裂迹象的必要性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Aortoenteric fistula caused by a ruptured stent-graft: a case report.

Purpose: To report a case of aortoenteric fistula secondary to endovascular abdominal aortic aneurysm (AAA) exclusion using the Stentor bifurcated endovascular graft.

Methods and results: Seventeen months after a successful endovascular AAA procedure, a male patient developed upper gastrointestinal bleeding. An aortoenteric fistula was diagnosed. At operation, the endograft fabric was found to be ruptured in an area of suture disruption between the nitinol stents. Coincidentally, a pre-existing inflammatory process might have caused adhesions between the bowel and the aortic wall, predisposing to fistula formation. The patient recovered after placement of a conventional aortic graft.

Conclusions: Suture disruption between the internal support stents is a recognized complication in the first-generation Stentor device. Although the case described here is probably not typical of the consequences of this sequela, it does reinforce the need for continual periodic imaging to check for signs of graft disruption in Stentor endografts.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Aorto-left renal vein fistula: is there a place for endovascular management? Aortocaval fistula: a challenge for endovascular management. Endovascular repair of an aortoenteric fistula in a high-risk patient. Carotid stenting using radial artery access. Neurological monitoring during carotid artery stenting: the Duck Squeezing Test.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1