[一种连续监测高危心脏病患者外周血管和肺血管总阻力的方法]。

Anaesthesiologie und Reanimation Pub Date : 1999-01-01
H Apitzsch, D Olthoff, S Lange, V Thiem
{"title":"[一种连续监测高危心脏病患者外周血管和肺血管总阻力的方法]。","authors":"H Apitzsch,&nbsp;D Olthoff,&nbsp;S Lange,&nbsp;V Thiem","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>In this study we present a computer-assisted monitoring system (\"Opserver\") which allows a continuous registration of directly measured values: hear rate (HR), systolic, diastolic and mean arterial pressure (SAP, DAP, MAP): systolic, diastolic and mean pulmonary arterial pressure (PAPs, PAPd, PAPm), central venous pressure (CVP), mixed venous oxygen saturation (SvO2), pulse-oxymetrically measured oxygen saturation (SaO2), cardiac output (CO) and calculated haemodynamic parameters: cardiac index (CI), total peripheral vascular resistance (TPVR) and pulmonary vascular resistance (PVR). The basic principle of this on-line monitoring system is the registration of calculated parameters combining data of various devices by specially-developed software. The procedure is shown in several clinical examples. The advantages of this system are:--monitoring of critical haemodynamic responses in cardiac high-risk patients relating to induction and finishing of anaesthesia including in- and extubation, recovery from anaesthesia, operation and transport and--exact documentation of the data for the purpose of clinical studies. Based on continuous measurement, this monitoring system allows an optimum evaluation of cardiorespiratory acute incidents, thereby permitting a problem-oriented therapy in high-risk patients with vasoactive medication in the perioperative period and in the intensive care unit.</p>","PeriodicalId":76993,"journal":{"name":"Anaesthesiologie und Reanimation","volume":"24 5","pages":"116-9"},"PeriodicalIF":0.0000,"publicationDate":"1999-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[A method for continuous monitoring of total peripheral and pulmonary vascular resistance in high risk cardiac patients].\",\"authors\":\"H Apitzsch,&nbsp;D Olthoff,&nbsp;S Lange,&nbsp;V Thiem\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>In this study we present a computer-assisted monitoring system (\\\"Opserver\\\") which allows a continuous registration of directly measured values: hear rate (HR), systolic, diastolic and mean arterial pressure (SAP, DAP, MAP): systolic, diastolic and mean pulmonary arterial pressure (PAPs, PAPd, PAPm), central venous pressure (CVP), mixed venous oxygen saturation (SvO2), pulse-oxymetrically measured oxygen saturation (SaO2), cardiac output (CO) and calculated haemodynamic parameters: cardiac index (CI), total peripheral vascular resistance (TPVR) and pulmonary vascular resistance (PVR). The basic principle of this on-line monitoring system is the registration of calculated parameters combining data of various devices by specially-developed software. The procedure is shown in several clinical examples. The advantages of this system are:--monitoring of critical haemodynamic responses in cardiac high-risk patients relating to induction and finishing of anaesthesia including in- and extubation, recovery from anaesthesia, operation and transport and--exact documentation of the data for the purpose of clinical studies. Based on continuous measurement, this monitoring system allows an optimum evaluation of cardiorespiratory acute incidents, thereby permitting a problem-oriented therapy in high-risk patients with vasoactive medication in the perioperative period and in the intensive care unit.</p>\",\"PeriodicalId\":76993,\"journal\":{\"name\":\"Anaesthesiologie und Reanimation\",\"volume\":\"24 5\",\"pages\":\"116-9\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1999-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Anaesthesiologie und Reanimation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Anaesthesiologie und Reanimation","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在这项研究中,我们提出了一个计算机辅助监测系统(“Opserver”),它可以连续记录直接测量的值:心率(HR),收缩压,舒张压和平均动脉压(SAP, DAP, MAP);收缩压,舒张压和平均肺动脉压(PAPs, PAPd, PAPm),中心静脉压(CVP),混合静脉氧饱和度(SvO2),脉搏氧饱和度(SaO2),心输出量(CO)和计算的血流动力学参数。心脏指数(CI)、总外周血管阻力(TPVR)和肺血管阻力(PVR)。该在线监测系统的基本原理是通过专门开发的软件,结合各种设备的数据,对计算参数进行配准。该方法在几个临床实例中得到了展示。该系统的优点是:监测与麻醉诱导和结束相关的心脏高危患者的关键血流动力学反应,包括插管和拔管,麻醉恢复,手术和运输,以及为临床研究目的准确记录数据。基于连续测量,该监测系统允许对心肺急性事件进行最佳评估,从而允许在围手术期和重症监护病房使用血管活性药物的高危患者进行问题导向治疗。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
[A method for continuous monitoring of total peripheral and pulmonary vascular resistance in high risk cardiac patients].

In this study we present a computer-assisted monitoring system ("Opserver") which allows a continuous registration of directly measured values: hear rate (HR), systolic, diastolic and mean arterial pressure (SAP, DAP, MAP): systolic, diastolic and mean pulmonary arterial pressure (PAPs, PAPd, PAPm), central venous pressure (CVP), mixed venous oxygen saturation (SvO2), pulse-oxymetrically measured oxygen saturation (SaO2), cardiac output (CO) and calculated haemodynamic parameters: cardiac index (CI), total peripheral vascular resistance (TPVR) and pulmonary vascular resistance (PVR). The basic principle of this on-line monitoring system is the registration of calculated parameters combining data of various devices by specially-developed software. The procedure is shown in several clinical examples. The advantages of this system are:--monitoring of critical haemodynamic responses in cardiac high-risk patients relating to induction and finishing of anaesthesia including in- and extubation, recovery from anaesthesia, operation and transport and--exact documentation of the data for the purpose of clinical studies. Based on continuous measurement, this monitoring system allows an optimum evaluation of cardiorespiratory acute incidents, thereby permitting a problem-oriented therapy in high-risk patients with vasoactive medication in the perioperative period and in the intensive care unit.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
[Regional anaesthesia versus general anaesthesia--pathophysiology and clinical implications]. [Analgesia, sedation and anaesthesia in emergency service]. [The influence of normobaric hyperoxia on hepatic oxygenation--experience with an animal model]. [Perioperative management of a patient with alcaptonuria--a case report]. [Implantable drug pumps for spinal opioid analgesia: technical solutions and problems].
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1