{"title":"比较经典的手动推楔形膜,与改进的自动化方法,使血液涂片。","authors":"L Benattar,&nbsp;G Flandrin","doi":"10.1007/s00282-999-0211-7","DOIUrl":null,"url":null,"abstract":"<p><p>Comparison of apparatus for automatically spreading peripheral blood films (GENES) to manual wedge-pull technique has been performed, showing that the average size of optimal area for counting is twice larger in automated smears compared to manual ones. The variability of WBC repartition has been studied in doing differential count on manual and automated smears and both are compared to results obtain with an independent technique (Coulter STKS) for differential. The correlation coefficients for each WBC population show a closer relationship between automated smear preparations and reference instrument (STKS) than with manual spreading smears. Monocyte differential is particularly influenced by the variability of manual spreading procedures.</p>","PeriodicalId":73231,"journal":{"name":"Hematology and cell therapy","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1999-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1007/s00282-999-0211-7","citationCount":"13","resultStr":"{\"title\":\"Comparison of the classical manual pushed wedge films, with an improved automated method for making blood smears.\",\"authors\":\"L Benattar,&nbsp;G Flandrin\",\"doi\":\"10.1007/s00282-999-0211-7\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Comparison of apparatus for automatically spreading peripheral blood films (GENES) to manual wedge-pull technique has been performed, showing that the average size of optimal area for counting is twice larger in automated smears compared to manual ones. The variability of WBC repartition has been studied in doing differential count on manual and automated smears and both are compared to results obtain with an independent technique (Coulter STKS) for differential. The correlation coefficients for each WBC population show a closer relationship between automated smear preparations and reference instrument (STKS) than with manual spreading smears. Monocyte differential is particularly influenced by the variability of manual spreading procedures.</p>\",\"PeriodicalId\":73231,\"journal\":{\"name\":\"Hematology and cell therapy\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1999-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1007/s00282-999-0211-7\",\"citationCount\":\"13\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Hematology and cell therapy\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1007/s00282-999-0211-7\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Hematology and cell therapy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s00282-999-0211-7","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 13

摘要

将自动涂布外周血膜(GENES)的仪器与人工楔拉技术进行了比较,结果表明,自动涂布的最佳计数区域的平均大小是人工涂布的两倍。在手工和自动涂片上进行差异计数时,研究了白细胞再分配的可变性,并将两者与独立技术(Coulter STKS)的差异结果进行了比较。每个白细胞群的相关系数显示,自动涂片制备与参考仪器(STKS)之间的关系比人工涂片更密切。单核细胞的差异特别受到人工扩散过程的可变性的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Comparison of the classical manual pushed wedge films, with an improved automated method for making blood smears.

Comparison of apparatus for automatically spreading peripheral blood films (GENES) to manual wedge-pull technique has been performed, showing that the average size of optimal area for counting is twice larger in automated smears compared to manual ones. The variability of WBC repartition has been studied in doing differential count on manual and automated smears and both are compared to results obtain with an independent technique (Coulter STKS) for differential. The correlation coefficients for each WBC population show a closer relationship between automated smear preparations and reference instrument (STKS) than with manual spreading smears. Monocyte differential is particularly influenced by the variability of manual spreading procedures.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Allogeneic bone marrow tranplantation for young adult patients with newly diagnosed acute myeloid leukemia: HLA-Matched sibling donor availability does not improve treatment ouctome Imbalance between the number of patients supplying stem cells for autologous transplantation and the number of patients receiving such transplants in France in 1997 and 1998 Autologous peripheral blood stem cell transplantation (PBSCT) in acute myeloid leukaemia (AML) in first complete remission (CR) a report of the BGMT cooperative group about 32 patients VECP-Bleo regimen as treatment of advanced stage aggressive non-Hodgkin’s Lymphoma in elderly patients a GOELAMS protocol Cost analysis of allogeneic bone marrow transplantation
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1