使用新型铜银宫内节育器nova - t380两年临床经验。

I Batár, A Kuukankorpi, I Rauramo, M Siljander
{"title":"使用新型铜银宫内节育器nova - t380两年临床经验。","authors":"I Batár,&nbsp;A Kuukankorpi,&nbsp;I Rauramo,&nbsp;M Siljander","doi":"10.1023/a:1006631511642","DOIUrl":null,"url":null,"abstract":"<p><p>In 1992, an open single-group phase III clinical trial was started at three centers to investigate the clinical performance of the high copper surface area Nova-T 380, a modification of Nova-T. This report presents the interim results of the first two years of use. A total of 400 women volunteers were enrolled in the study. The mean age was 31.4 years (SD 5.5) with a minimum of 18 and a maximum of 44 years. At the cut-off date, 259 women had passed the 24-month visit. Gross cumulative life-table rates at the end of the first and second years, respectively, calculated by the Kaplan-Meier method, were as follows: pregnancy 0.5 and 1.6, expulsion 1.6 and 2.8, bleeding 4.7 and 8.7, pain 1.3 and 2.3, removal for other medical reasons 1.7 and 3.9, planning pregnancy 1.1 and 6.0, removal for other personal reasons 0.5 and 1.5, per 100 users. No ectopic pregnancies or PIDs occurred. The continuation rates were 89.0 and 75.5 at 12 and 24 months, respectively. The first two-year performance of the Nova-T 380 was good. Bleeding problems were in the same range as with devices with smaller copper surface areas. No unexpected serious adverse events were encountered.</p>","PeriodicalId":76977,"journal":{"name":"Advances in contraception : the official journal of the Society for the Advancement of Contraception","volume":"15 1","pages":"37-48"},"PeriodicalIF":0.0000,"publicationDate":"1999-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1023/a:1006631511642","citationCount":"14","resultStr":"{\"title\":\"Two-year clinical experience with Nova-T 380, a novel copper-silver IUD.\",\"authors\":\"I Batár,&nbsp;A Kuukankorpi,&nbsp;I Rauramo,&nbsp;M Siljander\",\"doi\":\"10.1023/a:1006631511642\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>In 1992, an open single-group phase III clinical trial was started at three centers to investigate the clinical performance of the high copper surface area Nova-T 380, a modification of Nova-T. This report presents the interim results of the first two years of use. A total of 400 women volunteers were enrolled in the study. The mean age was 31.4 years (SD 5.5) with a minimum of 18 and a maximum of 44 years. At the cut-off date, 259 women had passed the 24-month visit. Gross cumulative life-table rates at the end of the first and second years, respectively, calculated by the Kaplan-Meier method, were as follows: pregnancy 0.5 and 1.6, expulsion 1.6 and 2.8, bleeding 4.7 and 8.7, pain 1.3 and 2.3, removal for other medical reasons 1.7 and 3.9, planning pregnancy 1.1 and 6.0, removal for other personal reasons 0.5 and 1.5, per 100 users. No ectopic pregnancies or PIDs occurred. The continuation rates were 89.0 and 75.5 at 12 and 24 months, respectively. The first two-year performance of the Nova-T 380 was good. Bleeding problems were in the same range as with devices with smaller copper surface areas. No unexpected serious adverse events were encountered.</p>\",\"PeriodicalId\":76977,\"journal\":{\"name\":\"Advances in contraception : the official journal of the Society for the Advancement of Contraception\",\"volume\":\"15 1\",\"pages\":\"37-48\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1999-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1023/a:1006631511642\",\"citationCount\":\"14\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Advances in contraception : the official journal of the Society for the Advancement of Contraception\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1023/a:1006631511642\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advances in contraception : the official journal of the Society for the Advancement of Contraception","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1023/a:1006631511642","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 14

摘要

1992年,在三个中心开展了一项开放的单组III期临床试验,以研究高铜表面积nova - t380 (Nova-T的改良版)的临床性能。本报告介绍了前两年使用的中期结果。总共有400名女性志愿者参加了这项研究。平均年龄31.4岁(SD 5.5),最小18岁,最大44岁。截止日期,有259名妇女通过了为期24个月的访问。根据Kaplan-Meier方法计算,第一年和第二年结束时的总累积生命表率分别如下:每100名使用者中,怀孕0.5和1.6,排出1.6和2.8,出血4.7和8.7,疼痛1.3和2.3,因其他医疗原因切除1.7和3.9,计划妊娠1.1和6.0,因其他个人原因切除0.5和1.5。未发生异位妊娠或妊高征。12个月和24个月的延续率分别为89.0和75.5。nova - t380头两年的表现不错。出血问题与铜表面积较小的装置在同一范围内。未发生意外的严重不良事件。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Two-year clinical experience with Nova-T 380, a novel copper-silver IUD.

In 1992, an open single-group phase III clinical trial was started at three centers to investigate the clinical performance of the high copper surface area Nova-T 380, a modification of Nova-T. This report presents the interim results of the first two years of use. A total of 400 women volunteers were enrolled in the study. The mean age was 31.4 years (SD 5.5) with a minimum of 18 and a maximum of 44 years. At the cut-off date, 259 women had passed the 24-month visit. Gross cumulative life-table rates at the end of the first and second years, respectively, calculated by the Kaplan-Meier method, were as follows: pregnancy 0.5 and 1.6, expulsion 1.6 and 2.8, bleeding 4.7 and 8.7, pain 1.3 and 2.3, removal for other medical reasons 1.7 and 3.9, planning pregnancy 1.1 and 6.0, removal for other personal reasons 0.5 and 1.5, per 100 users. No ectopic pregnancies or PIDs occurred. The continuation rates were 89.0 and 75.5 at 12 and 24 months, respectively. The first two-year performance of the Nova-T 380 was good. Bleeding problems were in the same range as with devices with smaller copper surface areas. No unexpected serious adverse events were encountered.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Nota editorial Workshop papers Free communications 1 Free communications 2 Free communications 3
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1