【七氟醚平衡吸入麻醉范围内的可乐定——对pEEG参数的影响】。

Anaesthesiologie und Reanimation Pub Date : 2000-01-01
T Frank, V Thieme, D Olthoff
{"title":"【七氟醚平衡吸入麻醉范围内的可乐定——对pEEG参数的影响】。","authors":"T Frank,&nbsp;V Thieme,&nbsp;D Olthoff","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The anaesthetic-saving property of clonidine has often been reported. In our own prospective, randomized study, in which the depth of anaesthesia was controlled by using spectral edge frequency (target-SEF90 = 10 Hz) and clinical parameters, we confirmed the anaesthetic-saving property only for fentanyl (-20%). On the other hand, there was no difference in MAC-sevoflurane values between the groups in keeping a steady target-SEF. For this reason, we analysed the stored pEEG data with regard to clonidine-specific effects. Twenty-eight patients were included in our study. The patients were randomly treated preoperatively with an infusion of 4 micrograms/kg KG Clonidine (clonidine group) or a placebo (placebo group). For anaesthesia, a standardized procedure with fentanyl, propofol, rocuronium, N2O/O2/sevoflurane was performed. The depth of anaesthesia was controlled by using SEF90 and clinical parameters. SEF90, SEF50 and the EEG power-spectrum were analysed over a five-minute period in the steady state of anaesthesia without surgical manipulation. Both placebo and the clonidine showed comparable values for SEF90 (9.9 +/- 1 vs. 10.7 +/- 0.9 Hz). On the other hand, there were differences in the SEF50 values between the groups (3.3 +/- 0.7 vs. 6.4 +/- 2.2 Hz). In the clonidine group, relative alpha-power was higher than in the placebo group (36.3 +/- 15.8 vs. 16.8 +/- 8.8%). Parallel to this effect, there was a reduction in relative delta-power in the clonidine group (47.6 +/- 15.2 vs. 65.4 +/- 9.1%). The described EEG effects on the power-spectrum inevitably influence SEF50 and SEF90. In our opinion, SEF50 is not a powerful predictor of depth of anaesthesia, when anaesthesia is performed in the way described. By performing this variation of balanced anaesthesia and co-medication with clonidine, higher values of SEF90 (11-14 Hz) seem to be adequate for surgical manipulation.</p>","PeriodicalId":76993,"journal":{"name":"Anaesthesiologie und Reanimation","volume":"25 2","pages":"32-6"},"PeriodicalIF":0.0000,"publicationDate":"2000-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Clonidine within the scope of balanced inhalation anesthesia with sevoflurane--effects on pEEG parameters].\",\"authors\":\"T Frank,&nbsp;V Thieme,&nbsp;D Olthoff\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The anaesthetic-saving property of clonidine has often been reported. In our own prospective, randomized study, in which the depth of anaesthesia was controlled by using spectral edge frequency (target-SEF90 = 10 Hz) and clinical parameters, we confirmed the anaesthetic-saving property only for fentanyl (-20%). On the other hand, there was no difference in MAC-sevoflurane values between the groups in keeping a steady target-SEF. For this reason, we analysed the stored pEEG data with regard to clonidine-specific effects. Twenty-eight patients were included in our study. The patients were randomly treated preoperatively with an infusion of 4 micrograms/kg KG Clonidine (clonidine group) or a placebo (placebo group). For anaesthesia, a standardized procedure with fentanyl, propofol, rocuronium, N2O/O2/sevoflurane was performed. The depth of anaesthesia was controlled by using SEF90 and clinical parameters. SEF90, SEF50 and the EEG power-spectrum were analysed over a five-minute period in the steady state of anaesthesia without surgical manipulation. Both placebo and the clonidine showed comparable values for SEF90 (9.9 +/- 1 vs. 10.7 +/- 0.9 Hz). On the other hand, there were differences in the SEF50 values between the groups (3.3 +/- 0.7 vs. 6.4 +/- 2.2 Hz). In the clonidine group, relative alpha-power was higher than in the placebo group (36.3 +/- 15.8 vs. 16.8 +/- 8.8%). Parallel to this effect, there was a reduction in relative delta-power in the clonidine group (47.6 +/- 15.2 vs. 65.4 +/- 9.1%). The described EEG effects on the power-spectrum inevitably influence SEF50 and SEF90. In our opinion, SEF50 is not a powerful predictor of depth of anaesthesia, when anaesthesia is performed in the way described. By performing this variation of balanced anaesthesia and co-medication with clonidine, higher values of SEF90 (11-14 Hz) seem to be adequate for surgical manipulation.</p>\",\"PeriodicalId\":76993,\"journal\":{\"name\":\"Anaesthesiologie und Reanimation\",\"volume\":\"25 2\",\"pages\":\"32-6\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2000-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Anaesthesiologie und Reanimation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Anaesthesiologie und Reanimation","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

可乐定的麻醉性经常被报道。在我们自己的前瞻性随机研究中,通过频谱边缘频率(目标- sef90 = 10 Hz)和临床参数控制麻醉深度,我们证实了芬太尼的麻醉保存特性(-20%)。另一方面,在保持稳定的目标sef方面,两组之间的mac -七氟烷值没有差异。出于这个原因,我们分析了存储的pEEG数据关于可乐定特异性效应。我们的研究纳入了28名患者。患者术前随机输注4微克/千克千克可乐定(可乐定组)或安慰剂(安慰剂组)。对于麻醉,采用芬太尼、异丙酚、罗库溴铵、N2O/O2/七氟醚的标准化程序。采用SEF90及临床参数控制麻醉深度。在没有手术操作的稳定麻醉状态下,分析5分钟内SEF90、SEF50和脑电图功率谱。安慰剂和可乐定的SEF90值具有可比性(9.9 +/- 1 vs 10.7 +/- 0.9 Hz)。另一方面,两组之间的SEF50值存在差异(3.3 +/- 0.7 vs. 6.4 +/- 2.2 Hz)。在可乐定组中,相对α -功率高于安慰剂组(36.3 +/- 15.8 vs 16.8 +/- 8.8%)。与此效应平行,可乐定组的相对δ功率降低(47.6 +/- 15.2 vs. 65.4 +/- 9.1%)。所描述的EEG对功率谱的影响不可避免地影响SEF50和SEF90。在我们看来,SEF50不是一个强有力的预测深度的麻醉,当麻醉是在上述方式进行。通过执行这种平衡麻醉和与可乐定联合用药的变化,较高的SEF90值(11-14 Hz)似乎足以用于手术操作。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
[Clonidine within the scope of balanced inhalation anesthesia with sevoflurane--effects on pEEG parameters].

The anaesthetic-saving property of clonidine has often been reported. In our own prospective, randomized study, in which the depth of anaesthesia was controlled by using spectral edge frequency (target-SEF90 = 10 Hz) and clinical parameters, we confirmed the anaesthetic-saving property only for fentanyl (-20%). On the other hand, there was no difference in MAC-sevoflurane values between the groups in keeping a steady target-SEF. For this reason, we analysed the stored pEEG data with regard to clonidine-specific effects. Twenty-eight patients were included in our study. The patients were randomly treated preoperatively with an infusion of 4 micrograms/kg KG Clonidine (clonidine group) or a placebo (placebo group). For anaesthesia, a standardized procedure with fentanyl, propofol, rocuronium, N2O/O2/sevoflurane was performed. The depth of anaesthesia was controlled by using SEF90 and clinical parameters. SEF90, SEF50 and the EEG power-spectrum were analysed over a five-minute period in the steady state of anaesthesia without surgical manipulation. Both placebo and the clonidine showed comparable values for SEF90 (9.9 +/- 1 vs. 10.7 +/- 0.9 Hz). On the other hand, there were differences in the SEF50 values between the groups (3.3 +/- 0.7 vs. 6.4 +/- 2.2 Hz). In the clonidine group, relative alpha-power was higher than in the placebo group (36.3 +/- 15.8 vs. 16.8 +/- 8.8%). Parallel to this effect, there was a reduction in relative delta-power in the clonidine group (47.6 +/- 15.2 vs. 65.4 +/- 9.1%). The described EEG effects on the power-spectrum inevitably influence SEF50 and SEF90. In our opinion, SEF50 is not a powerful predictor of depth of anaesthesia, when anaesthesia is performed in the way described. By performing this variation of balanced anaesthesia and co-medication with clonidine, higher values of SEF90 (11-14 Hz) seem to be adequate for surgical manipulation.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
[Regional anaesthesia versus general anaesthesia--pathophysiology and clinical implications]. [Analgesia, sedation and anaesthesia in emergency service]. [The influence of normobaric hyperoxia on hepatic oxygenation--experience with an animal model]. [Perioperative management of a patient with alcaptonuria--a case report]. [Implantable drug pumps for spinal opioid analgesia: technical solutions and problems].
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1