{"title":"Jasco CD-995:同时测量化学和对映体纯度的检测器的评价。","authors":"M R Hadley, G D Jonas","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>An evaluation of the use of the Jasco CD-995 in conjunction with achiral high-performance liquid chromatography (HPLC) for the determination of the enantiomeric purity of various SB compounds is described. The Jasco CD-995 is the first commercially-available detector specifically designed for the on-line monitoring of circular dichroism (CD) at a fixed wavelength. Predecessors such as the OR-990 from Jasco and other manufacturers use optical rotation as the detection principle. The results demonstrate that where enantiomeric purity is required to be controlled at levels greater than 99% w/w it is unlikely that the use of the CD-995 with achiral HPLC will compare with the sensitivity of enantio-selective HPLC and capillary electrophoresis (CE). In contrast, where the control of enantiomeric purity is required at levels less than 99% w/w good agreement can be achieved between the CD-995 with achiral HPLC and these techniques. Furthermore, the ability of the CD-995 in such situations to monitor ordinary UV absorbance and CD facilitates the simultaneous measurement of chemical and enantiomeric purity. The benefits in terms of \"faster, information-rich analyses\" are clear.</p>","PeriodicalId":11752,"journal":{"name":"Enantiomer","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2000-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"An evaluation of the Jasco CD-995: a detector for the simultaneous measurement of chemical and enantiomeric purity.\",\"authors\":\"M R Hadley, G D Jonas\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>An evaluation of the use of the Jasco CD-995 in conjunction with achiral high-performance liquid chromatography (HPLC) for the determination of the enantiomeric purity of various SB compounds is described. The Jasco CD-995 is the first commercially-available detector specifically designed for the on-line monitoring of circular dichroism (CD) at a fixed wavelength. Predecessors such as the OR-990 from Jasco and other manufacturers use optical rotation as the detection principle. The results demonstrate that where enantiomeric purity is required to be controlled at levels greater than 99% w/w it is unlikely that the use of the CD-995 with achiral HPLC will compare with the sensitivity of enantio-selective HPLC and capillary electrophoresis (CE). In contrast, where the control of enantiomeric purity is required at levels less than 99% w/w good agreement can be achieved between the CD-995 with achiral HPLC and these techniques. Furthermore, the ability of the CD-995 in such situations to monitor ordinary UV absorbance and CD facilitates the simultaneous measurement of chemical and enantiomeric purity. The benefits in terms of \\\"faster, information-rich analyses\\\" are clear.</p>\",\"PeriodicalId\":11752,\"journal\":{\"name\":\"Enantiomer\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2000-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Enantiomer\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Enantiomer","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
An evaluation of the Jasco CD-995: a detector for the simultaneous measurement of chemical and enantiomeric purity.
An evaluation of the use of the Jasco CD-995 in conjunction with achiral high-performance liquid chromatography (HPLC) for the determination of the enantiomeric purity of various SB compounds is described. The Jasco CD-995 is the first commercially-available detector specifically designed for the on-line monitoring of circular dichroism (CD) at a fixed wavelength. Predecessors such as the OR-990 from Jasco and other manufacturers use optical rotation as the detection principle. The results demonstrate that where enantiomeric purity is required to be controlled at levels greater than 99% w/w it is unlikely that the use of the CD-995 with achiral HPLC will compare with the sensitivity of enantio-selective HPLC and capillary electrophoresis (CE). In contrast, where the control of enantiomeric purity is required at levels less than 99% w/w good agreement can be achieved between the CD-995 with achiral HPLC and these techniques. Furthermore, the ability of the CD-995 in such situations to monitor ordinary UV absorbance and CD facilitates the simultaneous measurement of chemical and enantiomeric purity. The benefits in terms of "faster, information-rich analyses" are clear.