秘鲁一家公立医院T380A铜宫内节育器停用率的相关因素

F Escudero, G F Gonzales, L Delgadillo, A E Villena
{"title":"秘鲁一家公立医院T380A铜宫内节育器停用率的相关因素","authors":"F Escudero,&nbsp;G F Gonzales,&nbsp;L Delgadillo,&nbsp;A E Villena","doi":"10.1023/a:1006792409169","DOIUrl":null,"url":null,"abstract":"<p><p>The objectives of this study were to evaluate performance and causes of discontinuation of the Copper T380A IUD by users at the Family Planning Service at Hospital Arzobispo Loayza in Lima, Peru, during a period of three years. The study included 3167 acceptors of the CuT380A attending the service during 1992-1994. IUDs were inserted during interval timing. Follow-up was at 1, 12, 24 and 36 months after insertion. The following events were recorded: number of pregnancies, expulsions and all causes of discontinuation. The cumulative rates per 100 woman-years using the life-table method was calculated. Also calculated were the relative risks for expulsion and for pregnancy. At the end of the study, 361 women had discontinued the method for various reasons, whereas 1667 women continued using the method. The lost-to-follow-up proportion increased over time from 35.9 per 100 woman-years for the first year to 38.2 for the third year. The cumulative discontinuation rate over three years was 22.6 +/- 1.3 (cumulative rate +/- standard error) per 100 woman-years. The cumulative pregnancy rate for three years was 1.2 +/- 0.4 per 100 woman-years, whereas the cumulative rate of expulsion was 4.9 +/- 0.4 for the first, 6.4 for the second and 6.8 for the third year. The main cause of discontinuation during the first year of use was expulsion (4.9 per 100 woman-years) followed by personal reasons (2.1 per 100 woman-years). At the end of the third year, the main cause was personal reasons (11.4) and the second cause was expulsion (6.8). A higher probability of expulsion, pregnancy and discontinuation for bleeding and/or pain was associated with age less than 20 years. In conclusion, the effectiveness of the CuT380A IUD after three years of use was 98.8 per 100 woman-years, whereas continuation was 39.2, and loss to follow-up increased over time.</p>","PeriodicalId":76977,"journal":{"name":"Advances in contraception : the official journal of the Society for the Advancement of Contraception","volume":"15 4","pages":"303-11"},"PeriodicalIF":0.0000,"publicationDate":"1999-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1023/a:1006792409169","citationCount":"9","resultStr":"{\"title\":\"Factors associated with discontinuation rates of the copper T380A IUD in a Peruvian public hospital.\",\"authors\":\"F Escudero,&nbsp;G F Gonzales,&nbsp;L Delgadillo,&nbsp;A E Villena\",\"doi\":\"10.1023/a:1006792409169\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The objectives of this study were to evaluate performance and causes of discontinuation of the Copper T380A IUD by users at the Family Planning Service at Hospital Arzobispo Loayza in Lima, Peru, during a period of three years. The study included 3167 acceptors of the CuT380A attending the service during 1992-1994. IUDs were inserted during interval timing. Follow-up was at 1, 12, 24 and 36 months after insertion. The following events were recorded: number of pregnancies, expulsions and all causes of discontinuation. The cumulative rates per 100 woman-years using the life-table method was calculated. Also calculated were the relative risks for expulsion and for pregnancy. At the end of the study, 361 women had discontinued the method for various reasons, whereas 1667 women continued using the method. The lost-to-follow-up proportion increased over time from 35.9 per 100 woman-years for the first year to 38.2 for the third year. The cumulative discontinuation rate over three years was 22.6 +/- 1.3 (cumulative rate +/- standard error) per 100 woman-years. The cumulative pregnancy rate for three years was 1.2 +/- 0.4 per 100 woman-years, whereas the cumulative rate of expulsion was 4.9 +/- 0.4 for the first, 6.4 for the second and 6.8 for the third year. The main cause of discontinuation during the first year of use was expulsion (4.9 per 100 woman-years) followed by personal reasons (2.1 per 100 woman-years). At the end of the third year, the main cause was personal reasons (11.4) and the second cause was expulsion (6.8). A higher probability of expulsion, pregnancy and discontinuation for bleeding and/or pain was associated with age less than 20 years. In conclusion, the effectiveness of the CuT380A IUD after three years of use was 98.8 per 100 woman-years, whereas continuation was 39.2, and loss to follow-up increased over time.</p>\",\"PeriodicalId\":76977,\"journal\":{\"name\":\"Advances in contraception : the official journal of the Society for the Advancement of Contraception\",\"volume\":\"15 4\",\"pages\":\"303-11\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1999-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1023/a:1006792409169\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Advances in contraception : the official journal of the Society for the Advancement of Contraception\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1023/a:1006792409169\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advances in contraception : the official journal of the Society for the Advancement of Contraception","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1023/a:1006792409169","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

摘要

本研究的目的是评估秘鲁利马Arzobispo Loayza医院计划生育服务处用户在三年期间停用铜T380A宫内节育器的表现和原因。该研究包括3167名在1992-1994年期间参加该服务的CuT380A接受者。在间隔时间插入宫内节育器。随访时间分别为插入后1、12、24和36个月。记录了下列事件:怀孕次数、驱逐和所有终止妊娠的原因。使用生命表法计算每100名妇女年的累积比率。还计算了被驱逐和怀孕的相对风险。在研究结束时,361名妇女因各种原因停止了这种方法,而1667名妇女继续使用这种方法。随着时间的推移,失去随访的比例从第一年的35.9 / 100女性年增加到第三年的38.2 / 100女性年。三年内的累积停药率为每100名妇女年22.6±1.3(累积率±标准误差)。3年累计怀孕率为每100名妇女年1.2 +/- 0.4,而第1年累计驱逐率为4.9 +/- 0.4,第2年为6.4,第3年为6.8。在使用的第一年停止使用的主要原因是驱逐(每100名妇女年4.9人),其次是个人原因(每100名妇女年2.1人)。在第三年末,主要原因是个人原因(11.4),其次是开除(6.8)。年龄小于20岁的患者排药、妊娠和因出血和/或疼痛停药的可能性较高。总之,CuT380A宫内节育器使用三年后的有效性为98.8 / 100女性年,而继续使用的有效性为39.2 / 100女性年,随时间的推移,随访损失增加。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Factors associated with discontinuation rates of the copper T380A IUD in a Peruvian public hospital.

The objectives of this study were to evaluate performance and causes of discontinuation of the Copper T380A IUD by users at the Family Planning Service at Hospital Arzobispo Loayza in Lima, Peru, during a period of three years. The study included 3167 acceptors of the CuT380A attending the service during 1992-1994. IUDs were inserted during interval timing. Follow-up was at 1, 12, 24 and 36 months after insertion. The following events were recorded: number of pregnancies, expulsions and all causes of discontinuation. The cumulative rates per 100 woman-years using the life-table method was calculated. Also calculated were the relative risks for expulsion and for pregnancy. At the end of the study, 361 women had discontinued the method for various reasons, whereas 1667 women continued using the method. The lost-to-follow-up proportion increased over time from 35.9 per 100 woman-years for the first year to 38.2 for the third year. The cumulative discontinuation rate over three years was 22.6 +/- 1.3 (cumulative rate +/- standard error) per 100 woman-years. The cumulative pregnancy rate for three years was 1.2 +/- 0.4 per 100 woman-years, whereas the cumulative rate of expulsion was 4.9 +/- 0.4 for the first, 6.4 for the second and 6.8 for the third year. The main cause of discontinuation during the first year of use was expulsion (4.9 per 100 woman-years) followed by personal reasons (2.1 per 100 woman-years). At the end of the third year, the main cause was personal reasons (11.4) and the second cause was expulsion (6.8). A higher probability of expulsion, pregnancy and discontinuation for bleeding and/or pain was associated with age less than 20 years. In conclusion, the effectiveness of the CuT380A IUD after three years of use was 98.8 per 100 woman-years, whereas continuation was 39.2, and loss to follow-up increased over time.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Nota editorial Workshop papers Free communications 1 Free communications 2 Free communications 3
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1