Shogo Nishi , Yasuhide Nakayama , Hatsue Ueda-Ishibashi , Takehisa Matsuda
{"title":"用带有微孔的载肝素支架栓塞实验性动脉瘤","authors":"Shogo Nishi ,&nbsp;Yasuhide Nakayama ,&nbsp;Hatsue Ueda-Ishibashi ,&nbsp;Takehisa Matsuda","doi":"10.1016/S1522-1865(03)00114-8","DOIUrl":null,"url":null,"abstract":"<div><p><strong>Purpose:</strong> For percutaneous transluminal angioplasty (PTA), a heparin-loaded stent graft, composed of a commercially available metallic stent with a microporous and surface-modified thin film, has been developed. Early controlled endothelialization is promoted by a regular array of micropores produced by an excimer laser ablation technique. Early thrombus is prevented by a drug delivery system established by impregnation of photoreactive gelatin with heparin. Our stent grafts were used for embolization of experimental carotid aneurysms with an autologous external jugular vein patch in dogs. <strong>Materials and methods:</strong> At 1 month after formation, the aneurysms were occluded with stent grafts. Affected arteries were removed with the aneurysms, immediately (two aneurysms in one dog), 1 week (four aneurysms in two dogs), 1 month (three aneurysms in two dogs) and 3 months (four aneurysms in two dogs) after embolization, and were studied histologically to evaluate patency and endothelialization over the intraluminal surface of the thin film. <strong>Results:</strong> Treated carotid arteries were all patent with occluded aneurysms completely at any periods. Even at 1 week after embolization, endothelialization was confirmed on the surface of the stent graft on the lumen side. At 1 and 3 months, all treated aneurysms with enough patent parent arteries were filled with organized tissues and completely occluded. <strong>Conclusion:</strong> Our developed stent graft appears to be promising for the treatment of aneurysms, especially with respect to immediate termination of blood inflow and early endothelialization in the neck of the aneurysm.</p></div>","PeriodicalId":80261,"journal":{"name":"Cardiovascular radiation medicine","volume":"4 1","pages":"Pages 29-33"},"PeriodicalIF":0.0000,"publicationDate":"2003-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S1522-1865(03)00114-8","citationCount":"15","resultStr":"{\"title\":\"Embolization of experimental aneurysms using a heparin-loaded stent graft with micropores\",\"authors\":\"Shogo Nishi ,&nbsp;Yasuhide Nakayama ,&nbsp;Hatsue Ueda-Ishibashi ,&nbsp;Takehisa Matsuda\",\"doi\":\"10.1016/S1522-1865(03)00114-8\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p><strong>Purpose:</strong> For percutaneous transluminal angioplasty (PTA), a heparin-loaded stent graft, composed of a commercially available metallic stent with a microporous and surface-modified thin film, has been developed. Early controlled endothelialization is promoted by a regular array of micropores produced by an excimer laser ablation technique. Early thrombus is prevented by a drug delivery system established by impregnation of photoreactive gelatin with heparin. Our stent grafts were used for embolization of experimental carotid aneurysms with an autologous external jugular vein patch in dogs. <strong>Materials and methods:</strong> At 1 month after formation, the aneurysms were occluded with stent grafts. Affected arteries were removed with the aneurysms, immediately (two aneurysms in one dog), 1 week (four aneurysms in two dogs), 1 month (three aneurysms in two dogs) and 3 months (four aneurysms in two dogs) after embolization, and were studied histologically to evaluate patency and endothelialization over the intraluminal surface of the thin film. <strong>Results:</strong> Treated carotid arteries were all patent with occluded aneurysms completely at any periods. Even at 1 week after embolization, endothelialization was confirmed on the surface of the stent graft on the lumen side. At 1 and 3 months, all treated aneurysms with enough patent parent arteries were filled with organized tissues and completely occluded. <strong>Conclusion:</strong> Our developed stent graft appears to be promising for the treatment of aneurysms, especially with respect to immediate termination of blood inflow and early endothelialization in the neck of the aneurysm.</p></div>\",\"PeriodicalId\":80261,\"journal\":{\"name\":\"Cardiovascular radiation medicine\",\"volume\":\"4 1\",\"pages\":\"Pages 29-33\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2003-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/S1522-1865(03)00114-8\",\"citationCount\":\"15\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Cardiovascular radiation medicine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1522186503001148\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cardiovascular radiation medicine","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1522186503001148","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 15

摘要

目的:为经皮腔内血管成形术(PTA),开发了一种肝素负载支架,由市买金属支架与微孔和表面改性薄膜组成。早期受控内皮化是由准分子激光烧蚀技术产生的规则微孔阵列促进的。早期血栓是通过将光反应性明胶与肝素浸渍而建立的药物输送系统来预防的。我们的支架移植被用于用自体颈外静脉贴片栓塞实验性颈动脉动脉瘤。材料和方法:动脉瘤形成后1个月,用支架闭塞。栓塞后立即(1只狗2个动脉瘤)、1周(2只狗4个动脉瘤)、1个月(2只狗3个动脉瘤)和3个月(2只狗4个动脉瘤)切除病变动脉,并进行组织学研究,评估膜腔内表面的通畅程度和内皮化程度。结果:经治疗的颈动脉在任何时期均通畅且动脉瘤闭塞。即使在栓塞后1周,在管腔一侧的支架表面也证实了内皮化。在1个月和3个月时,所有治疗过的动脉瘤均有足够通畅的主动脉,充满有组织的组织并完全闭塞。结论:我们开发的支架移植对于动脉瘤的治疗似乎是有希望的,特别是在动脉瘤颈部立即终止血液流入和早期内皮化方面。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Embolization of experimental aneurysms using a heparin-loaded stent graft with micropores

Purpose: For percutaneous transluminal angioplasty (PTA), a heparin-loaded stent graft, composed of a commercially available metallic stent with a microporous and surface-modified thin film, has been developed. Early controlled endothelialization is promoted by a regular array of micropores produced by an excimer laser ablation technique. Early thrombus is prevented by a drug delivery system established by impregnation of photoreactive gelatin with heparin. Our stent grafts were used for embolization of experimental carotid aneurysms with an autologous external jugular vein patch in dogs. Materials and methods: At 1 month after formation, the aneurysms were occluded with stent grafts. Affected arteries were removed with the aneurysms, immediately (two aneurysms in one dog), 1 week (four aneurysms in two dogs), 1 month (three aneurysms in two dogs) and 3 months (four aneurysms in two dogs) after embolization, and were studied histologically to evaluate patency and endothelialization over the intraluminal surface of the thin film. Results: Treated carotid arteries were all patent with occluded aneurysms completely at any periods. Even at 1 week after embolization, endothelialization was confirmed on the surface of the stent graft on the lumen side. At 1 and 3 months, all treated aneurysms with enough patent parent arteries were filled with organized tissues and completely occluded. Conclusion: Our developed stent graft appears to be promising for the treatment of aneurysms, especially with respect to immediate termination of blood inflow and early endothelialization in the neck of the aneurysm.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Abstracts No change in endothelial-dependent vasomotion late after coronary irradiation Clinical and angiographic outcomes of cardiac transplant patients treated with intracoronary beta-radiation for in-stent restenosis Brachytherapy with gamma radiation of a coronary artery for in-stent restenosis may induce the regression of in-stent restenosis of an adjacent coronary artery without angioplasty. First case report and review of the literature Endovascular treatment of peripheral vascular disease: before or after coronary surgery?
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1