{"title":"受核影响的传统和特殊类型住宅的损坏。","authors":"P A RANDALL","doi":"10.2172/4029823","DOIUrl":null,"url":null,"abstract":"Ten residential structures of wood, brick, lightweight reinforced concrete block, and lightweight precast concrete slabs were exposed in pairs to the effects of a nuclear device of approximately 30 kt yield, detonated atop a 500-ft tower. The houses represented various structural types, and two houses of each type were tested. One house was located at an anticipated overpressure at which collapse or major damage might be expected and the other was located at an anticipated overpressure at which damage without collapse might be expected. The one-story reinforced lightweight concrete block house and the one-story precast lightweight concrete house suffered only minor structural damage. Photographs are included of the houses both before and after damage. Motion pictures were made during the event and were analyzed for information on thermal and blast effects. Recommendations are included for strengthening the structures within the limits of practical economy and so providing increased protection to dwelling structures. (C.H.)","PeriodicalId":86826,"journal":{"name":"ORINS [reports]. U.S. Atomic Energy Commission","volume":"WT-1194 ","pages":"1-83"},"PeriodicalIF":0.0000,"publicationDate":"1961-04-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":"{\"title\":\"Damage to conventional and special types of residences exposed to nuclear effects.\",\"authors\":\"P A RANDALL\",\"doi\":\"10.2172/4029823\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Ten residential structures of wood, brick, lightweight reinforced concrete block, and lightweight precast concrete slabs were exposed in pairs to the effects of a nuclear device of approximately 30 kt yield, detonated atop a 500-ft tower. The houses represented various structural types, and two houses of each type were tested. One house was located at an anticipated overpressure at which collapse or major damage might be expected and the other was located at an anticipated overpressure at which damage without collapse might be expected. The one-story reinforced lightweight concrete block house and the one-story precast lightweight concrete house suffered only minor structural damage. Photographs are included of the houses both before and after damage. Motion pictures were made during the event and were analyzed for information on thermal and blast effects. Recommendations are included for strengthening the structures within the limits of practical economy and so providing increased protection to dwelling structures. (C.H.)\",\"PeriodicalId\":86826,\"journal\":{\"name\":\"ORINS [reports]. U.S. Atomic Energy Commission\",\"volume\":\"WT-1194 \",\"pages\":\"1-83\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1961-04-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ORINS [reports]. U.S. Atomic Energy Commission\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2172/4029823\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ORINS [reports]. U.S. Atomic Energy Commission","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2172/4029823","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Damage to conventional and special types of residences exposed to nuclear effects.
Ten residential structures of wood, brick, lightweight reinforced concrete block, and lightweight precast concrete slabs were exposed in pairs to the effects of a nuclear device of approximately 30 kt yield, detonated atop a 500-ft tower. The houses represented various structural types, and two houses of each type were tested. One house was located at an anticipated overpressure at which collapse or major damage might be expected and the other was located at an anticipated overpressure at which damage without collapse might be expected. The one-story reinforced lightweight concrete block house and the one-story precast lightweight concrete house suffered only minor structural damage. Photographs are included of the houses both before and after damage. Motion pictures were made during the event and were analyzed for information on thermal and blast effects. Recommendations are included for strengthening the structures within the limits of practical economy and so providing increased protection to dwelling structures. (C.H.)