[基于LINAC立体定向照射CIRS SHANE幻象脑肿瘤的剂量学分析]。

Q4 Medicine Magyar onkologia Pub Date : 2021-03-17 Epub Date: 2020-07-17
Dalma Mihály, Barbara Melles-Bencsik, Tamás Pócza, Gábor Kontra, Tibor Major, András Bajcsay, Csaba Polgár, Csilla Pesznyák
{"title":"[基于LINAC立体定向照射CIRS SHANE幻象脑肿瘤的剂量学分析]。","authors":"Dalma Mihály,&nbsp;Barbara Melles-Bencsik,&nbsp;Tamás Pócza,&nbsp;Gábor Kontra,&nbsp;Tibor Major,&nbsp;András Bajcsay,&nbsp;Csaba Polgár,&nbsp;Csilla Pesznyák","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The aim of the study was to compare the different stereotactic treatment plans and dose calculation algorithms for small targets with film dosimetry in anthropomorphic phantom. Treatment plans were prepared for multiple targets with single setup isocenter. Plans for three different irradiation techniques were generated using conformal arc with four non-coplanar arcs, RapidArc with two coplanar full arcs and RapidArc with four non-coplanar arcs in the Varian Eclipse v13.7.16 TPS. Conformal arc and RapidArc plans were calculated using AAA, Acuros XBDm and XBDw algorithms. Conformity index, gradient index and dose maximum were calculated for all PTVs. All measurements were made on the Varian TrueBeam linear accelerator. Comparison between computed and measured dose distributions was performed with gamma evaluation criteria of 3%, 3 mm; 3%, 1 mm and 2%, 2 mm. According to our results, the Eclipse AAA and AXB algorithms provide accurate dose distributions for homogeneous cranial irradiation.</p>","PeriodicalId":18175,"journal":{"name":"Magyar onkologia","volume":"65 1","pages":"23-29"},"PeriodicalIF":0.0000,"publicationDate":"2021-03-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Dosimetric analysis of LINAC based stereotactic irradiation of brain tumours in CIRS SHANE phantom].\",\"authors\":\"Dalma Mihály,&nbsp;Barbara Melles-Bencsik,&nbsp;Tamás Pócza,&nbsp;Gábor Kontra,&nbsp;Tibor Major,&nbsp;András Bajcsay,&nbsp;Csaba Polgár,&nbsp;Csilla Pesznyák\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The aim of the study was to compare the different stereotactic treatment plans and dose calculation algorithms for small targets with film dosimetry in anthropomorphic phantom. Treatment plans were prepared for multiple targets with single setup isocenter. Plans for three different irradiation techniques were generated using conformal arc with four non-coplanar arcs, RapidArc with two coplanar full arcs and RapidArc with four non-coplanar arcs in the Varian Eclipse v13.7.16 TPS. Conformal arc and RapidArc plans were calculated using AAA, Acuros XBDm and XBDw algorithms. Conformity index, gradient index and dose maximum were calculated for all PTVs. All measurements were made on the Varian TrueBeam linear accelerator. Comparison between computed and measured dose distributions was performed with gamma evaluation criteria of 3%, 3 mm; 3%, 1 mm and 2%, 2 mm. According to our results, the Eclipse AAA and AXB algorithms provide accurate dose distributions for homogeneous cranial irradiation.</p>\",\"PeriodicalId\":18175,\"journal\":{\"name\":\"Magyar onkologia\",\"volume\":\"65 1\",\"pages\":\"23-29\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-03-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Magyar onkologia\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2020/7/17 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Magyar onkologia","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2020/7/17 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

本研究的目的是比较不同立体定向治疗方案和剂量计算算法的小目标与膜剂量法拟人幻影。采用单次等中心设置多靶点治疗方案。在Varian Eclipse v13.7.16 TPS中,使用共形电弧与4个非共面电弧、RapidArc与2个共面全电弧和RapidArc与4个非共面电弧生成三种不同辐照技术的方案。采用AAA、acros XBDm和XBDw算法计算共形弧和RapidArc平面。计算所有PTVs的符合性指数、梯度指数和最大剂量。所有测量都是在瓦里安TrueBeam直线加速器上进行的。以3%,3 mm的伽马评价标准对计算剂量分布和测量剂量分布进行比较;3%, 1mm和2%,2mm。根据我们的研究结果,Eclipse AAA和AXB算法为均匀的颅骨照射提供了准确的剂量分布。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
[Dosimetric analysis of LINAC based stereotactic irradiation of brain tumours in CIRS SHANE phantom].

The aim of the study was to compare the different stereotactic treatment plans and dose calculation algorithms for small targets with film dosimetry in anthropomorphic phantom. Treatment plans were prepared for multiple targets with single setup isocenter. Plans for three different irradiation techniques were generated using conformal arc with four non-coplanar arcs, RapidArc with two coplanar full arcs and RapidArc with four non-coplanar arcs in the Varian Eclipse v13.7.16 TPS. Conformal arc and RapidArc plans were calculated using AAA, Acuros XBDm and XBDw algorithms. Conformity index, gradient index and dose maximum were calculated for all PTVs. All measurements were made on the Varian TrueBeam linear accelerator. Comparison between computed and measured dose distributions was performed with gamma evaluation criteria of 3%, 3 mm; 3%, 1 mm and 2%, 2 mm. According to our results, the Eclipse AAA and AXB algorithms provide accurate dose distributions for homogeneous cranial irradiation.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Magyar onkologia
Magyar onkologia Medicine-Medicine (all)
CiteScore
0.60
自引率
0.00%
发文量
30
期刊最新文献
[The expanding possibilities of immuno-oncology treatments]. [Therapeutic drug monitoring for supporting oncological treatments: a new era begins]. [The role of classic serum tumor markers in the diagnosis and treatment monitoring of solid tumors in adults]. [Current therapeutic and familial implications of the genetic background of prostate cancer]. [Paraneoplastic endocrine syndromes: clinical picture and laboratory diagnostics].
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1