[肺多平面重建(MPR)病变的可检出性]。

Satoshi Kato, Atsushi Nambu, Akitoshi Saito, Tsutomu Araki
{"title":"[肺多平面重建(MPR)病变的可检出性]。","authors":"Satoshi Kato,&nbsp;Atsushi Nambu,&nbsp;Akitoshi Saito,&nbsp;Tsutomu Araki","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the diagnostic ability of multiplanar reformation (MPR) images of the lung in comparison with thin-section source CT images.</p><p><strong>Materials and methods: </strong>MPR images were reconstructed for 79 patients with suspected pulmonary disease. Slice thicknesses of source images were 2 mm in 24, 1 mm in 30, and 0.5 mm in 25 cases. The presence of centrilobular nodules, emphysema, bronchiectasis, ground-glass opacity (GGO), consolidation, interstitial thickening, and pulmonary nodule was evaluated on thin-section source images by an experienced chest radiologist to establish gold standards and then subsequently assessed on the MPR images independently by two radiologists. The sensitivity, specificity, and accuracy of each finding were calculated regarding the results of thin-section source images as the gold standards. Accuracy for the detection of findings was also statistically compared among the three groups of different source slice thicknesses using Fisher's exact test.</p><p><strong>Results: </strong>Accuracy for the detection of findings was significantly less (p < 0.05) in 2 mm slice MPR for centrilobular nodule, GGO, and interstitial thickening than in 1 mm or 0.5 mm slice MPR. No statistically significant difference was observed for any of the findings between 0.5 mm and 1 mm slice MPR. Rates of sensitivity, specificity, and accuracy of the MPR images for detection of the findings were 89-100%, 73-95%, and 84-95%, respectively.</p><p><strong>Conclusion: </strong>In comparison with thin-section source images, MPR images are comparably sensitive but not as specific for the detection of findings. When producing MPR images, the slice thickness of source images should be less than 2 mm.</p>","PeriodicalId":19251,"journal":{"name":"Nihon Igaku Hoshasen Gakkai zasshi. Nippon acta radiologica","volume":"65 4","pages":"378-83"},"PeriodicalIF":0.0000,"publicationDate":"2005-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Detectability of lesions in multiplanar reformation (MPR) of the lung].\",\"authors\":\"Satoshi Kato,&nbsp;Atsushi Nambu,&nbsp;Akitoshi Saito,&nbsp;Tsutomu Araki\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To evaluate the diagnostic ability of multiplanar reformation (MPR) images of the lung in comparison with thin-section source CT images.</p><p><strong>Materials and methods: </strong>MPR images were reconstructed for 79 patients with suspected pulmonary disease. Slice thicknesses of source images were 2 mm in 24, 1 mm in 30, and 0.5 mm in 25 cases. The presence of centrilobular nodules, emphysema, bronchiectasis, ground-glass opacity (GGO), consolidation, interstitial thickening, and pulmonary nodule was evaluated on thin-section source images by an experienced chest radiologist to establish gold standards and then subsequently assessed on the MPR images independently by two radiologists. The sensitivity, specificity, and accuracy of each finding were calculated regarding the results of thin-section source images as the gold standards. Accuracy for the detection of findings was also statistically compared among the three groups of different source slice thicknesses using Fisher's exact test.</p><p><strong>Results: </strong>Accuracy for the detection of findings was significantly less (p < 0.05) in 2 mm slice MPR for centrilobular nodule, GGO, and interstitial thickening than in 1 mm or 0.5 mm slice MPR. No statistically significant difference was observed for any of the findings between 0.5 mm and 1 mm slice MPR. Rates of sensitivity, specificity, and accuracy of the MPR images for detection of the findings were 89-100%, 73-95%, and 84-95%, respectively.</p><p><strong>Conclusion: </strong>In comparison with thin-section source images, MPR images are comparably sensitive but not as specific for the detection of findings. When producing MPR images, the slice thickness of source images should be less than 2 mm.</p>\",\"PeriodicalId\":19251,\"journal\":{\"name\":\"Nihon Igaku Hoshasen Gakkai zasshi. Nippon acta radiologica\",\"volume\":\"65 4\",\"pages\":\"378-83\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2005-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Nihon Igaku Hoshasen Gakkai zasshi. Nippon acta radiologica\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nihon Igaku Hoshasen Gakkai zasshi. Nippon acta radiologica","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:评价肺多平面重构(MPR)图像与薄层源CT图像的诊断能力。材料与方法:对79例疑似肺部疾病患者的MPR图像进行重建。源图像切片厚度24例为2mm, 30例为1mm, 25例为0.5 mm。小叶中心结节、肺气肿、支气管扩张、毛玻璃影(GGO)、实变、间质增厚和肺结节的存在由一位经验丰富的胸部放射科医生在薄层源图像上进行评估,以建立金标准,随后由两名放射科医生独立在MPR图像上进行评估。以薄切片源图像的结果为金标准,计算每个发现的灵敏度、特异性和准确性。采用Fisher精确检验,对三组不同源切片厚度的检测结果的准确性进行统计学比较。结果:2 mm片MPR对小叶中心结节、GGO、间质增厚的检出率明显低于1 mm或0.5 mm片MPR (p < 0.05)。在0.5 mm和1mm切片的MPR中,没有观察到统计学上的显著差异。MPR图像检测病灶的敏感性、特异性和准确性分别为89-100%、73-95%和84-95%。结论:与薄层源图像相比,MPR图像具有相当的敏感性,但对病灶的检测特异性较差。在生成MPR图像时,源图像的切片厚度应小于2mm。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
[Detectability of lesions in multiplanar reformation (MPR) of the lung].

Purpose: To evaluate the diagnostic ability of multiplanar reformation (MPR) images of the lung in comparison with thin-section source CT images.

Materials and methods: MPR images were reconstructed for 79 patients with suspected pulmonary disease. Slice thicknesses of source images were 2 mm in 24, 1 mm in 30, and 0.5 mm in 25 cases. The presence of centrilobular nodules, emphysema, bronchiectasis, ground-glass opacity (GGO), consolidation, interstitial thickening, and pulmonary nodule was evaluated on thin-section source images by an experienced chest radiologist to establish gold standards and then subsequently assessed on the MPR images independently by two radiologists. The sensitivity, specificity, and accuracy of each finding were calculated regarding the results of thin-section source images as the gold standards. Accuracy for the detection of findings was also statistically compared among the three groups of different source slice thicknesses using Fisher's exact test.

Results: Accuracy for the detection of findings was significantly less (p < 0.05) in 2 mm slice MPR for centrilobular nodule, GGO, and interstitial thickening than in 1 mm or 0.5 mm slice MPR. No statistically significant difference was observed for any of the findings between 0.5 mm and 1 mm slice MPR. Rates of sensitivity, specificity, and accuracy of the MPR images for detection of the findings were 89-100%, 73-95%, and 84-95%, respectively.

Conclusion: In comparison with thin-section source images, MPR images are comparably sensitive but not as specific for the detection of findings. When producing MPR images, the slice thickness of source images should be less than 2 mm.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
[Abstracts of the 45th Autumn Meeting of the Japanese Radiological Society. October 29-31, 2009. Wakayama, Japan]. [Abstracts of the 68th Annual Meeting of the Japanese Radiological Society. April 16-19, 2009. Yokohama, Japan]. [The 44th Autumn Meeting of the Japanese Radiological Society. Fukushima, Japan. October 22-24, 2008. Abstracts]. [The 67th Annual Meeting of the Japanese Radiological Society. Yokohama, Japan. April 4-6, 2008. Abstracts]. [The 43rd autumn meeting of the Japan Radiological Society. Nagoya, Japan. October 25-27, 2007. Abstracts].
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1