{"title":"肌瘤的生物磁及多普勒鉴别。","authors":"Panagiotis Anastasiadis, Achilleas N Anastasiadis, Athanasia Kotini, Nikoleta Koutlaki, Photios Anninos","doi":"10.1186/1477-044X-4-3","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>To elucidate the hemodynamics of the uterine artery myomas by use of Doppler ultrasound and biomagnetic measurements.</p><p><strong>Method: </strong>Twenty-four women were included in the study. Sixteen of them were characterised with large myomas whereas 8 of them with small ones. Biomagnetic signals of uterine arteries myomas were recorded and analyzed with Fourier analysis. The biomagnetic signals were distributed according to spectral amplitudes as high (140-300 ft/ radicalHz), low (50-110 ft/ radicalHz) and borderline (111-139 ft/ radicalHz). Uterine artery waveform measurements were evaluated by use of Pulsatility Index (PI) (normal value PI < 1.45).</p><p><strong>Results: </strong>There was a statistically significant difference between large and small myomas concerning the waveform amplitudes (P < 0.0005) and the PI index (P < 0.0005). Specifically, we noticed high biomagnetic amplitudes in most large myomas (93.75 %) and low biomagnetic amplitudes in most small ones (87.5 %).</p><p><strong>Conclusion: </strong>It is suggested that the biomagnetic recordings of uterine artery myomas could be a valuable modality in the estimation of the circulation of blood cells justifying the findings of Doppler velocimetry examination.</p>","PeriodicalId":8888,"journal":{"name":"Biomagnetic Research and Technology","volume":"4 ","pages":"3"},"PeriodicalIF":0.0000,"publicationDate":"2006-04-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1186/1477-044X-4-3","citationCount":"1","resultStr":"{\"title\":\"Differentiation of myomas by means of biomagnetic and doppler findings.\",\"authors\":\"Panagiotis Anastasiadis, Achilleas N Anastasiadis, Athanasia Kotini, Nikoleta Koutlaki, Photios Anninos\",\"doi\":\"10.1186/1477-044X-4-3\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Aim: </strong>To elucidate the hemodynamics of the uterine artery myomas by use of Doppler ultrasound and biomagnetic measurements.</p><p><strong>Method: </strong>Twenty-four women were included in the study. Sixteen of them were characterised with large myomas whereas 8 of them with small ones. Biomagnetic signals of uterine arteries myomas were recorded and analyzed with Fourier analysis. The biomagnetic signals were distributed according to spectral amplitudes as high (140-300 ft/ radicalHz), low (50-110 ft/ radicalHz) and borderline (111-139 ft/ radicalHz). Uterine artery waveform measurements were evaluated by use of Pulsatility Index (PI) (normal value PI < 1.45).</p><p><strong>Results: </strong>There was a statistically significant difference between large and small myomas concerning the waveform amplitudes (P < 0.0005) and the PI index (P < 0.0005). Specifically, we noticed high biomagnetic amplitudes in most large myomas (93.75 %) and low biomagnetic amplitudes in most small ones (87.5 %).</p><p><strong>Conclusion: </strong>It is suggested that the biomagnetic recordings of uterine artery myomas could be a valuable modality in the estimation of the circulation of blood cells justifying the findings of Doppler velocimetry examination.</p>\",\"PeriodicalId\":8888,\"journal\":{\"name\":\"Biomagnetic Research and Technology\",\"volume\":\"4 \",\"pages\":\"3\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-04-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1186/1477-044X-4-3\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biomagnetic Research and Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1186/1477-044X-4-3\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomagnetic Research and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/1477-044X-4-3","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Differentiation of myomas by means of biomagnetic and doppler findings.
Aim: To elucidate the hemodynamics of the uterine artery myomas by use of Doppler ultrasound and biomagnetic measurements.
Method: Twenty-four women were included in the study. Sixteen of them were characterised with large myomas whereas 8 of them with small ones. Biomagnetic signals of uterine arteries myomas were recorded and analyzed with Fourier analysis. The biomagnetic signals were distributed according to spectral amplitudes as high (140-300 ft/ radicalHz), low (50-110 ft/ radicalHz) and borderline (111-139 ft/ radicalHz). Uterine artery waveform measurements were evaluated by use of Pulsatility Index (PI) (normal value PI < 1.45).
Results: There was a statistically significant difference between large and small myomas concerning the waveform amplitudes (P < 0.0005) and the PI index (P < 0.0005). Specifically, we noticed high biomagnetic amplitudes in most large myomas (93.75 %) and low biomagnetic amplitudes in most small ones (87.5 %).
Conclusion: It is suggested that the biomagnetic recordings of uterine artery myomas could be a valuable modality in the estimation of the circulation of blood cells justifying the findings of Doppler velocimetry examination.