分析种植体的牙合:Tekscan的TScan III。

Dental implantology update Pub Date : 2007-09-01
Arun K Garg
{"title":"分析种植体的牙合:Tekscan的TScan III。","authors":"Arun K Garg","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Though no single, specific occlusal pattern has been developed that is ideal for oral implantology, research suggests some general criteria for deciding on a particular occlusal pattern that will help reduce cuspal interferences and lessen horizontal or lateral forces on the fixtures. Anticipated occlusal and chewing forces need to be taken under consideration for any implant-supported prosthesis. In addition, opposing dentition, as well as potential parafunctional mandibular movements, should be noted. Tekscan's T-Scan Occlusal Analysis System can help clinicians meet the needs of their patients for reliable measurements of occlusal biting forces. The T-Scan III System is Tekscan's most recent attempt to help dental clinicians obtain consistent and useful occlusal data for the placement, analysis, and repair of dental implants.</p>","PeriodicalId":77097,"journal":{"name":"Dental implantology update","volume":"18 9","pages":"65-70"},"PeriodicalIF":0.0000,"publicationDate":"2007-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Analyzing dental occlusion for implants: Tekscan's TScan III.\",\"authors\":\"Arun K Garg\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Though no single, specific occlusal pattern has been developed that is ideal for oral implantology, research suggests some general criteria for deciding on a particular occlusal pattern that will help reduce cuspal interferences and lessen horizontal or lateral forces on the fixtures. Anticipated occlusal and chewing forces need to be taken under consideration for any implant-supported prosthesis. In addition, opposing dentition, as well as potential parafunctional mandibular movements, should be noted. Tekscan's T-Scan Occlusal Analysis System can help clinicians meet the needs of their patients for reliable measurements of occlusal biting forces. The T-Scan III System is Tekscan's most recent attempt to help dental clinicians obtain consistent and useful occlusal data for the placement, analysis, and repair of dental implants.</p>\",\"PeriodicalId\":77097,\"journal\":{\"name\":\"Dental implantology update\",\"volume\":\"18 9\",\"pages\":\"65-70\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Dental implantology update\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Dental implantology update","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

虽然没有单一的,特定的咬合模式已经发展成为理想的口腔种植,研究提出了一些通用的标准来决定一个特定的咬合模式,这将有助于减少尖牙干扰和减少对固定装置的水平或侧向力。预期的咬合和咀嚼力需要考虑到任何种植体支持的假体。此外,相反的牙列,以及潜在的副功能下颌运动,应注意。Tekscan的T-Scan咬合分析系统可以帮助临床医生满足患者对咬合咬合力可靠测量的需求。T-Scan III系统是Tekscan最新的尝试,旨在帮助牙科临床医生获得一致和有用的咬合数据,用于牙种植体的放置、分析和修复。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Analyzing dental occlusion for implants: Tekscan's TScan III.

Though no single, specific occlusal pattern has been developed that is ideal for oral implantology, research suggests some general criteria for deciding on a particular occlusal pattern that will help reduce cuspal interferences and lessen horizontal or lateral forces on the fixtures. Anticipated occlusal and chewing forces need to be taken under consideration for any implant-supported prosthesis. In addition, opposing dentition, as well as potential parafunctional mandibular movements, should be noted. Tekscan's T-Scan Occlusal Analysis System can help clinicians meet the needs of their patients for reliable measurements of occlusal biting forces. The T-Scan III System is Tekscan's most recent attempt to help dental clinicians obtain consistent and useful occlusal data for the placement, analysis, and repair of dental implants.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Influence of platelet-rich plasma on dental implants. Osseointegration in well-controlled diabetic patients. Shear bond strength comparison of two different adhesive systems. Closer look: autofluorescence for oral cancer detection. Comparative evaluation of herbs and spices against bacterial pathogens. Making progress: considering standards of care.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1