{"title":"关于固定装置数量,手术技术和加载时间的作用。","authors":"Alf Eliasson","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Aims: </strong>The aims of this thesis were to analyze reduced number of implants supporting full arch fixed mandibular prostheses and fixed partial dentures (FPDs), non-submerged healing and early loading in the edentulous mandible. A further aim was to evaluate fit of Computer Numerical Controlled (CNC) milled I-Bridge frameworks.</p><p><strong>Material & methods: </strong>Paper I. One hundred and nineteen patients rehabilitated with full arch mandibular prostheses supported by four implants were evaluated after a mean follow-up of 4.4 years. Paper II. A total of 178 patients provided with FPDs supported by two (n=92) or three implants (n=122) of whom 123 were evaluated after a mean follow-up of 9.4 years. Paper III. Early and delayed loading of full arch mandibular prostheses were evaluated in 109 patients, 54 with delayed loading and 55 with early loading, with a mean follow-up of 3.6 years. Paper IV. Submerged and non-submerged implant placement for supporting fixed prostheses in the edentulous mandible were evaluated after five years in 29 patients. Paper V. The precision of fit of CNC-milled I-Bridge frameworks was evaluated using two different implant systems.</p><p><strong>Results: </strong>Paper I. The five-year cumulative survival rate (CSR) for implants was 99.1% and for prostheses 100%. Mean bone loss from baseline to five-year follow-up was 0.5 mm. No indication could be found that the number of supporting implants influenced the prosthetic complications. Paper II. The five-year implant and prosthesis CSR was 97.7% for two-implant supported FPDs and 97.3% for three-implant supported FPDs. Mean bone loss at five years was 0.4 mm. Significantly more prosthetic and abutment screw loosening were seen in two-implant supported FPDs. Paper III. Five-year CSR for implants was 94.4% and 92.5% for prostheses in early loading, and 97.9% and 98.0% in the delayed loading group. More prostheses needed adjustment or replacement in the early group, but patients treated with early loading were more pleased with the treatment procedure. Paper IV. Five-year CSR survival rate was 99.4%. Three implants fractured in one patient. Mean bone loss at five years was 0.7 mm in submerged implants and 0.5 mm in non-submerged implants. Paper V. All frameworks demonstrated clinically acceptable fit with mean distortion values within 23 microm (x-axis), 26 microm (y), 4 microm (z- axis) and 34 microm (3-D) for all frameworks. Control frameworks displayed greater levels of distortion than frameworks produced in a strict test situation.</p><p><strong>Conclusion: </strong>A reduction of the number of supporting implants to four implants in full arch mandibular prostheses and two implants in three unit FPDs in partial edentulous jaws resulted in the same clinical outcome as when more implants are used. Non-submerged implant placement in the edentulous mandible was as predictable as submerged, but early loading of implant-supported mandibular prostheses incurred more prosthetic complications. Computer numerical controlled milled frameworks presented levels of precision of fit within limits considered to be clinically acceptable and superior to earlier published results on cast frameworks.</p>","PeriodicalId":76572,"journal":{"name":"Swedish dental journal. Supplement","volume":" 197","pages":"3-95"},"PeriodicalIF":0.0000,"publicationDate":"2008-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"On the role of number of fixtures, surgical technique and timing of loading.\",\"authors\":\"Alf Eliasson\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Aims: </strong>The aims of this thesis were to analyze reduced number of implants supporting full arch fixed mandibular prostheses and fixed partial dentures (FPDs), non-submerged healing and early loading in the edentulous mandible. A further aim was to evaluate fit of Computer Numerical Controlled (CNC) milled I-Bridge frameworks.</p><p><strong>Material & methods: </strong>Paper I. One hundred and nineteen patients rehabilitated with full arch mandibular prostheses supported by four implants were evaluated after a mean follow-up of 4.4 years. Paper II. A total of 178 patients provided with FPDs supported by two (n=92) or three implants (n=122) of whom 123 were evaluated after a mean follow-up of 9.4 years. Paper III. Early and delayed loading of full arch mandibular prostheses were evaluated in 109 patients, 54 with delayed loading and 55 with early loading, with a mean follow-up of 3.6 years. Paper IV. Submerged and non-submerged implant placement for supporting fixed prostheses in the edentulous mandible were evaluated after five years in 29 patients. Paper V. The precision of fit of CNC-milled I-Bridge frameworks was evaluated using two different implant systems.</p><p><strong>Results: </strong>Paper I. The five-year cumulative survival rate (CSR) for implants was 99.1% and for prostheses 100%. Mean bone loss from baseline to five-year follow-up was 0.5 mm. No indication could be found that the number of supporting implants influenced the prosthetic complications. Paper II. The five-year implant and prosthesis CSR was 97.7% for two-implant supported FPDs and 97.3% for three-implant supported FPDs. Mean bone loss at five years was 0.4 mm. Significantly more prosthetic and abutment screw loosening were seen in two-implant supported FPDs. Paper III. Five-year CSR for implants was 94.4% and 92.5% for prostheses in early loading, and 97.9% and 98.0% in the delayed loading group. More prostheses needed adjustment or replacement in the early group, but patients treated with early loading were more pleased with the treatment procedure. Paper IV. Five-year CSR survival rate was 99.4%. Three implants fractured in one patient. Mean bone loss at five years was 0.7 mm in submerged implants and 0.5 mm in non-submerged implants. Paper V. All frameworks demonstrated clinically acceptable fit with mean distortion values within 23 microm (x-axis), 26 microm (y), 4 microm (z- axis) and 34 microm (3-D) for all frameworks. Control frameworks displayed greater levels of distortion than frameworks produced in a strict test situation.</p><p><strong>Conclusion: </strong>A reduction of the number of supporting implants to four implants in full arch mandibular prostheses and two implants in three unit FPDs in partial edentulous jaws resulted in the same clinical outcome as when more implants are used. Non-submerged implant placement in the edentulous mandible was as predictable as submerged, but early loading of implant-supported mandibular prostheses incurred more prosthetic complications. Computer numerical controlled milled frameworks presented levels of precision of fit within limits considered to be clinically acceptable and superior to earlier published results on cast frameworks.</p>\",\"PeriodicalId\":76572,\"journal\":{\"name\":\"Swedish dental journal. Supplement\",\"volume\":\" 197\",\"pages\":\"3-95\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Swedish dental journal. Supplement\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Swedish dental journal. Supplement","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:本论文的目的是分析全弓固定下颌假体和固定局部义齿(FPDs)的种植体数量减少,无牙下颌的非浸入愈合和早期负荷。进一步的目的是评估计算机数控(CNC)铣削工字桥框架的配合。材料与方法:论文一:对119例采用4种种植体支撑下颌全弓修复的患者进行平均随访4.4年的评估。论文二世。共有178名患者接受了两个(n=92)或三个(n=122)种植体支持的fpd,其中123名患者在平均随访9.4年后接受了评估。纸三世。109例患者进行全弓下颌假体的早期和延迟加载,其中延迟加载54例,提前加载55例,平均随访3.6年。论文四:对29例无牙下颌骨无牙固定假体5年后的潜水种植体和非潜水种植体放置效果进行评价。论文五:采用两种不同的种植体系统对数控铣削I-Bridge框架的配合精度进行了评估。结果:第一篇:种植体5年累积生存率为99.1%,假体5年累积生存率为100%。从基线到5年随访的平均骨质流失为0.5 mm。没有发现支持种植体数量影响假体并发症的迹象。论文二世。双种植体支持的fpd的5年种植体和假体CSR为97.7%,三种植体支持的fpd为97.3%。5年平均骨质流失为0.4 mm。在双种植体支持的fpd中,假体和基台螺钉松动明显更多。纸三世。早期加载组种植体的5年CSR分别为94.4%和92.5%,延迟加载组为97.9%和98.0%。早期组需要调整或更换的假体较多,但早期负荷治疗的患者对治疗过程更满意。论文四:CSR 5年生存率为99.4%。1例患者3个植入物骨折。浸入式种植体5年平均骨损失为0.7 mm,非浸入式种植体为0.5 mm。所有框架均表现出临床可接受的拟合,其平均畸变值在23微米(x轴)、26微米(y轴)、4微米(z轴)和34微米(3-D)范围内。控制框架比严格测试情况下产生的框架显示出更大程度的扭曲。结论:在全弓下颌义齿中减少4个种植体,在部分无牙颌中减少3个单元fpd中减少2个种植体,其临床效果与使用更多种植体时相同。无牙下颌骨非浸入式种植体的植入与浸入式种植体一样可预测,但种植体支持下颌假体的早期加载会导致更多的假体并发症。计算机数控铣削框架的拟合精度水平在临床可接受的范围内,优于早期发表的铸造框架的结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
On the role of number of fixtures, surgical technique and timing of loading.

Aims: The aims of this thesis were to analyze reduced number of implants supporting full arch fixed mandibular prostheses and fixed partial dentures (FPDs), non-submerged healing and early loading in the edentulous mandible. A further aim was to evaluate fit of Computer Numerical Controlled (CNC) milled I-Bridge frameworks.

Material & methods: Paper I. One hundred and nineteen patients rehabilitated with full arch mandibular prostheses supported by four implants were evaluated after a mean follow-up of 4.4 years. Paper II. A total of 178 patients provided with FPDs supported by two (n=92) or three implants (n=122) of whom 123 were evaluated after a mean follow-up of 9.4 years. Paper III. Early and delayed loading of full arch mandibular prostheses were evaluated in 109 patients, 54 with delayed loading and 55 with early loading, with a mean follow-up of 3.6 years. Paper IV. Submerged and non-submerged implant placement for supporting fixed prostheses in the edentulous mandible were evaluated after five years in 29 patients. Paper V. The precision of fit of CNC-milled I-Bridge frameworks was evaluated using two different implant systems.

Results: Paper I. The five-year cumulative survival rate (CSR) for implants was 99.1% and for prostheses 100%. Mean bone loss from baseline to five-year follow-up was 0.5 mm. No indication could be found that the number of supporting implants influenced the prosthetic complications. Paper II. The five-year implant and prosthesis CSR was 97.7% for two-implant supported FPDs and 97.3% for three-implant supported FPDs. Mean bone loss at five years was 0.4 mm. Significantly more prosthetic and abutment screw loosening were seen in two-implant supported FPDs. Paper III. Five-year CSR for implants was 94.4% and 92.5% for prostheses in early loading, and 97.9% and 98.0% in the delayed loading group. More prostheses needed adjustment or replacement in the early group, but patients treated with early loading were more pleased with the treatment procedure. Paper IV. Five-year CSR survival rate was 99.4%. Three implants fractured in one patient. Mean bone loss at five years was 0.7 mm in submerged implants and 0.5 mm in non-submerged implants. Paper V. All frameworks demonstrated clinically acceptable fit with mean distortion values within 23 microm (x-axis), 26 microm (y), 4 microm (z- axis) and 34 microm (3-D) for all frameworks. Control frameworks displayed greater levels of distortion than frameworks produced in a strict test situation.

Conclusion: A reduction of the number of supporting implants to four implants in full arch mandibular prostheses and two implants in three unit FPDs in partial edentulous jaws resulted in the same clinical outcome as when more implants are used. Non-submerged implant placement in the edentulous mandible was as predictable as submerged, but early loading of implant-supported mandibular prostheses incurred more prosthetic complications. Computer numerical controlled milled frameworks presented levels of precision of fit within limits considered to be clinically acceptable and superior to earlier published results on cast frameworks.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Experimental tooth clenching. A model for studying mechanisms of muscle pain. On implementation of an endodontic program. Evaluation of surgically assisted rapid maxillary expansion and orthodontic treatment. Effects on dental, skeletal and nasal structures and rhinological findings. Masticatory function and temporomandibular disorders in patients with dentofacial deformities. On dental caries and dental erosion in Swedish young adults.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1