{"title":"连续流系统在线过程监测的自动校准。","authors":"M Agudo, A Ríos, M Valcárcel, A Danet","doi":"10.1155/S1463924695000022","DOIUrl":null,"url":null,"abstract":"<p><p>An automatic procedure for calibration in continuous-flow systems is proposed. A flow gradient unit in the sample channel, controlled via a switching valve, delivers a concentration gradient of the standard so that the standard concentration varies with time after the flow-rate gradient is started. Thus, the signal (absorbance)- concentration relationship can be determined and checked for (recalibration) as frequently as required. The procedure was applied to a simulated continuous monitoring of hydrazine in waters, as well as to specific water samples that were spiked with hydrazine at different concentrations.</p>","PeriodicalId":22600,"journal":{"name":"The Journal of Automatic Chemistry","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1995-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1155/S1463924695000022","citationCount":"1","resultStr":"{\"title\":\"Automatic calibration for on-line process monitoring in continuous-flow systems.\",\"authors\":\"M Agudo, A Ríos, M Valcárcel, A Danet\",\"doi\":\"10.1155/S1463924695000022\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>An automatic procedure for calibration in continuous-flow systems is proposed. A flow gradient unit in the sample channel, controlled via a switching valve, delivers a concentration gradient of the standard so that the standard concentration varies with time after the flow-rate gradient is started. Thus, the signal (absorbance)- concentration relationship can be determined and checked for (recalibration) as frequently as required. The procedure was applied to a simulated continuous monitoring of hydrazine in waters, as well as to specific water samples that were spiked with hydrazine at different concentrations.</p>\",\"PeriodicalId\":22600,\"journal\":{\"name\":\"The Journal of Automatic Chemistry\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1995-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1155/S1463924695000022\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The Journal of Automatic Chemistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1155/S1463924695000022\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of Automatic Chemistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/S1463924695000022","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Automatic calibration for on-line process monitoring in continuous-flow systems.
An automatic procedure for calibration in continuous-flow systems is proposed. A flow gradient unit in the sample channel, controlled via a switching valve, delivers a concentration gradient of the standard so that the standard concentration varies with time after the flow-rate gradient is started. Thus, the signal (absorbance)- concentration relationship can be determined and checked for (recalibration) as frequently as required. The procedure was applied to a simulated continuous monitoring of hydrazine in waters, as well as to specific water samples that were spiked with hydrazine at different concentrations.