用一种新的颗粒介导的血清c反应蛋白免疫分析法诊断新生儿感染

S Kitahashi, N Tatsumi, S Tagawa, T Matsui, M Higashihata, H Shintaku, S Tomoda, I Tsuda
{"title":"用一种新的颗粒介导的血清c反应蛋白免疫分析法诊断新生儿感染","authors":"S Kitahashi,&nbsp;N Tatsumi,&nbsp;S Tagawa,&nbsp;T Matsui,&nbsp;M Higashihata,&nbsp;H Shintaku,&nbsp;S Tomoda,&nbsp;I Tsuda","doi":"10.1155/S146392469800025X","DOIUrl":null,"url":null,"abstract":"<p><p>C-reactive protein (CRP) levels were measured using a new particle-mediated immunoassay. Tests for precision and linearity of this method gave satisfactory results. The minimum sensitivity of the assay was 1 ng/ml. Interference by bilirubin (<220mg/l) and haemoglobin (<20g/l) was not observed. Using this method, CRP was assayed as a means of monitoring for infection in newborns up to 72 h after delivery. The pattern of time course elevation curves was similar for both groups (10 healthy subjects and 26 patients), but the serum CRP (ng/ml) of infected newborns rose significantly higher than in healthy subjects at 24 h after birth. The rate of increase of CRP (CRP; ng/ml/h) may be a more useful parameter to detect infection, since a significant change in CRP was apparent only 12 h after birth. The reported method was reliable and the parameters obtained were considered clinically useful for early detection of infection.</p>","PeriodicalId":22600,"journal":{"name":"The Journal of Automatic Chemistry","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1998-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1155/S146392469800025X","citationCount":"2","resultStr":"{\"title\":\"Diagnosis of infections in newborns using a new particle-mediated immunoassay for serum C-reactive protein.\",\"authors\":\"S Kitahashi,&nbsp;N Tatsumi,&nbsp;S Tagawa,&nbsp;T Matsui,&nbsp;M Higashihata,&nbsp;H Shintaku,&nbsp;S Tomoda,&nbsp;I Tsuda\",\"doi\":\"10.1155/S146392469800025X\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>C-reactive protein (CRP) levels were measured using a new particle-mediated immunoassay. Tests for precision and linearity of this method gave satisfactory results. The minimum sensitivity of the assay was 1 ng/ml. Interference by bilirubin (<220mg/l) and haemoglobin (<20g/l) was not observed. Using this method, CRP was assayed as a means of monitoring for infection in newborns up to 72 h after delivery. The pattern of time course elevation curves was similar for both groups (10 healthy subjects and 26 patients), but the serum CRP (ng/ml) of infected newborns rose significantly higher than in healthy subjects at 24 h after birth. The rate of increase of CRP (CRP; ng/ml/h) may be a more useful parameter to detect infection, since a significant change in CRP was apparent only 12 h after birth. The reported method was reliable and the parameters obtained were considered clinically useful for early detection of infection.</p>\",\"PeriodicalId\":22600,\"journal\":{\"name\":\"The Journal of Automatic Chemistry\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1998-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1155/S146392469800025X\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The Journal of Automatic Chemistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1155/S146392469800025X\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of Automatic Chemistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/S146392469800025X","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

c反应蛋白(CRP)水平采用一种新的颗粒介导免疫分析法测定。方法的精密度和线性度试验结果令人满意。该方法的最低灵敏度为1 ng/ml。胆红素的干扰(
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Diagnosis of infections in newborns using a new particle-mediated immunoassay for serum C-reactive protein.

C-reactive protein (CRP) levels were measured using a new particle-mediated immunoassay. Tests for precision and linearity of this method gave satisfactory results. The minimum sensitivity of the assay was 1 ng/ml. Interference by bilirubin (<220mg/l) and haemoglobin (<20g/l) was not observed. Using this method, CRP was assayed as a means of monitoring for infection in newborns up to 72 h after delivery. The pattern of time course elevation curves was similar for both groups (10 healthy subjects and 26 patients), but the serum CRP (ng/ml) of infected newborns rose significantly higher than in healthy subjects at 24 h after birth. The rate of increase of CRP (CRP; ng/ml/h) may be a more useful parameter to detect infection, since a significant change in CRP was apparent only 12 h after birth. The reported method was reliable and the parameters obtained were considered clinically useful for early detection of infection.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
product news From the editor's desk Product news Product News Meeting Reports
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1