经鼓室超声诊断梅尼埃病两种方法的比较:点击合电位/动作电位比值测量和音突合电位测量。

William P R Gibson
{"title":"经鼓室超声诊断梅尼埃病两种方法的比较:点击合电位/动作电位比值测量和音突合电位测量。","authors":"William P R Gibson","doi":"10.1080/00016480902729843","DOIUrl":null,"url":null,"abstract":"<p><strong>Conclusion: </strong>Transtympanic electrocochleography (TT ECochG) is helpful for the confirmation of Meniere's disease using tone burst stimuli to measure the amplitude of the frequency specific summating potentials (SP) but not when using the click evoked summating potential versus action potential ratio (SP/AP).</p><p><strong>Objectives: </strong>To evaluate the effectiveness of TT ECochG as a means of confirming the clinical diagnosis of Meniere's disease.</p><p><strong>Patients and methods: </strong>A total of 2,717 patients were referred for TT ECochG between August 1998 and September 2008. Each patient was assessed prospectively on clinical grounds according to the AAOHNS criteria and a scale devised by the author. A Meniere's group and a non-Meniere's group were determined and the TT ECochG results were compared between the groups that had similar hearing levels for the particular stimulus employed.</p><p><strong>Results: </strong>Click SP/AP measurements did not significantly differentiate between populations of Meniere's ears and non-Meniere's ears. Tone burst SP amplitude measurements were significantly different between the populations, especially using frequencies at 500 Hz, 1 kHz, and 2 kHz.</p>","PeriodicalId":7027,"journal":{"name":"Acta oto-laryngologica. Supplementum","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2009-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/00016480902729843","citationCount":"54","resultStr":"{\"title\":\"A comparison of two methods of using transtympanic electrocochleography for the diagnosis of Meniere's disease: click summating potential/action potential ratio measurements and tone burst summating potential measurements.\",\"authors\":\"William P R Gibson\",\"doi\":\"10.1080/00016480902729843\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Conclusion: </strong>Transtympanic electrocochleography (TT ECochG) is helpful for the confirmation of Meniere's disease using tone burst stimuli to measure the amplitude of the frequency specific summating potentials (SP) but not when using the click evoked summating potential versus action potential ratio (SP/AP).</p><p><strong>Objectives: </strong>To evaluate the effectiveness of TT ECochG as a means of confirming the clinical diagnosis of Meniere's disease.</p><p><strong>Patients and methods: </strong>A total of 2,717 patients were referred for TT ECochG between August 1998 and September 2008. Each patient was assessed prospectively on clinical grounds according to the AAOHNS criteria and a scale devised by the author. A Meniere's group and a non-Meniere's group were determined and the TT ECochG results were compared between the groups that had similar hearing levels for the particular stimulus employed.</p><p><strong>Results: </strong>Click SP/AP measurements did not significantly differentiate between populations of Meniere's ears and non-Meniere's ears. Tone burst SP amplitude measurements were significantly different between the populations, especially using frequencies at 500 Hz, 1 kHz, and 2 kHz.</p>\",\"PeriodicalId\":7027,\"journal\":{\"name\":\"Acta oto-laryngologica. Supplementum\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1080/00016480902729843\",\"citationCount\":\"54\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta oto-laryngologica. Supplementum\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1080/00016480902729843\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta oto-laryngologica. Supplementum","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/00016480902729843","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 54

摘要

结论:经鼓室耳蜗电图(TT ECochG)对Meniere病的诊断有一定的帮助,使用张力刺激测量频率特异性和电位(SP)的幅值,而使用点击诱发和电位与动作电位比(SP/AP)则没有帮助。目的:评价TT ECochG作为临床确诊梅尼埃病的手段的有效性。患者和方法:1998年8月至2008年9月间,共有2717例患者接受了TT ECochG。根据AAOHNS标准和作者设计的量表,对每位患者进行前瞻性临床评估。确定了梅尼埃氏组和非梅尼埃氏组,并比较了对特定刺激具有相似听力水平的两组之间的TT ECochG结果。结果:点击SP/AP测量在梅尼埃耳群体和非梅尼埃耳群体之间没有显著差异。音调突发SP振幅测量在种群之间有显著差异,特别是在500 Hz, 1 kHz和2 kHz频率下。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A comparison of two methods of using transtympanic electrocochleography for the diagnosis of Meniere's disease: click summating potential/action potential ratio measurements and tone burst summating potential measurements.

Conclusion: Transtympanic electrocochleography (TT ECochG) is helpful for the confirmation of Meniere's disease using tone burst stimuli to measure the amplitude of the frequency specific summating potentials (SP) but not when using the click evoked summating potential versus action potential ratio (SP/AP).

Objectives: To evaluate the effectiveness of TT ECochG as a means of confirming the clinical diagnosis of Meniere's disease.

Patients and methods: A total of 2,717 patients were referred for TT ECochG between August 1998 and September 2008. Each patient was assessed prospectively on clinical grounds according to the AAOHNS criteria and a scale devised by the author. A Meniere's group and a non-Meniere's group were determined and the TT ECochG results were compared between the groups that had similar hearing levels for the particular stimulus employed.

Results: Click SP/AP measurements did not significantly differentiate between populations of Meniere's ears and non-Meniere's ears. Tone burst SP amplitude measurements were significantly different between the populations, especially using frequencies at 500 Hz, 1 kHz, and 2 kHz.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Nasopharyngitis. Towards a consensus on a hearing preservation classification system. A tissue-engineering approach for stenosis of the trachea and/or cricoid. Impacts and limitations of medialization thyroplasty on swallowing function of patients with unilateral vocal fold paralysis. Distribution of bone marrow-derived cells in the vestibular end organs and the endolymphatic sac.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1