{"title":"验证了HPLC-UV法测定天然草药小檗(Berberis aristata DC)及其提取物和市售阿育吠陀剂型中小檗碱的含量。","authors":"Anubhuti Pasrija, Rahul Singh, Chandra Kant Katiyar","doi":"10.4103/0974-7788.76789","DOIUrl":null,"url":null,"abstract":"<p><p>A new, simple, sensitive, selective, and precise high-performance liquid chromatography (HPLC) method for analysis of berberine in crude plant material, herbal extract, and ayurvedic dosage forms was developed and validated. The stationary phase was inert sil C(18) column The mobile phase consisting of acetonitrile (HPLC Grade) and potassium dihydrogen phosphate buffer (pH 2.5) in a gradient flow was used.The column was equilibrated with the mobile phase (flow rate 1.0 ml/min); elution was monitored at 346 nm. The linear regression analysis data for the calibration plots showed good linear relationship, with r(2)= 0.9942 in the concentration range of 16380-30420 μg/ml with respect to the peak area. The method was validated for specificity, precision, recovery, and linearity according to the International Conference on Harmonization guidelines. Statistical analysis of the data showed that the method is reproducible and selective for the estimation of berberine.</p>","PeriodicalId":88901,"journal":{"name":"International journal of Ayurveda research","volume":"1 4","pages":"243-6"},"PeriodicalIF":0.0000,"publicationDate":"2010-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.4103/0974-7788.76789","citationCount":"32","resultStr":"{\"title\":\"Validated HPLC-UV method for the determination of berberine in raw herb Daruharidra (Berberis aristata DC), its extract, and in commercially marketed Ayurvedic dosage forms.\",\"authors\":\"Anubhuti Pasrija, Rahul Singh, Chandra Kant Katiyar\",\"doi\":\"10.4103/0974-7788.76789\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A new, simple, sensitive, selective, and precise high-performance liquid chromatography (HPLC) method for analysis of berberine in crude plant material, herbal extract, and ayurvedic dosage forms was developed and validated. The stationary phase was inert sil C(18) column The mobile phase consisting of acetonitrile (HPLC Grade) and potassium dihydrogen phosphate buffer (pH 2.5) in a gradient flow was used.The column was equilibrated with the mobile phase (flow rate 1.0 ml/min); elution was monitored at 346 nm. The linear regression analysis data for the calibration plots showed good linear relationship, with r(2)= 0.9942 in the concentration range of 16380-30420 μg/ml with respect to the peak area. The method was validated for specificity, precision, recovery, and linearity according to the International Conference on Harmonization guidelines. Statistical analysis of the data showed that the method is reproducible and selective for the estimation of berberine.</p>\",\"PeriodicalId\":88901,\"journal\":{\"name\":\"International journal of Ayurveda research\",\"volume\":\"1 4\",\"pages\":\"243-6\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.4103/0974-7788.76789\",\"citationCount\":\"32\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International journal of Ayurveda research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/0974-7788.76789\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International journal of Ayurveda research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/0974-7788.76789","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Validated HPLC-UV method for the determination of berberine in raw herb Daruharidra (Berberis aristata DC), its extract, and in commercially marketed Ayurvedic dosage forms.
A new, simple, sensitive, selective, and precise high-performance liquid chromatography (HPLC) method for analysis of berberine in crude plant material, herbal extract, and ayurvedic dosage forms was developed and validated. The stationary phase was inert sil C(18) column The mobile phase consisting of acetonitrile (HPLC Grade) and potassium dihydrogen phosphate buffer (pH 2.5) in a gradient flow was used.The column was equilibrated with the mobile phase (flow rate 1.0 ml/min); elution was monitored at 346 nm. The linear regression analysis data for the calibration plots showed good linear relationship, with r(2)= 0.9942 in the concentration range of 16380-30420 μg/ml with respect to the peak area. The method was validated for specificity, precision, recovery, and linearity according to the International Conference on Harmonization guidelines. Statistical analysis of the data showed that the method is reproducible and selective for the estimation of berberine.