不同外科医生和不同解剖结构髋关节表面置换术导航的准确性。

Q Medicine Computer Aided Surgery Pub Date : 2012-01-01 DOI:10.3109/10929088.2011.652674
Iris Schleicher, Matthias Haselbacher, Eckart Mayr, Peter M Kaiser, Florian W Lenze, Alexander Keiler, Michael Nogler
{"title":"不同外科医生和不同解剖结构髋关节表面置换术导航的准确性。","authors":"Iris Schleicher,&nbsp;Matthias Haselbacher,&nbsp;Eckart Mayr,&nbsp;Peter M Kaiser,&nbsp;Florian W Lenze,&nbsp;Alexander Keiler,&nbsp;Michael Nogler","doi":"10.3109/10929088.2011.652674","DOIUrl":null,"url":null,"abstract":"<p><p>The accuracy of a commercial imageless navigation system for hip resurfacing and its reproducibility among different surgeons and for varying femoral anatomy was tested by comparing conventional and navigated implantation of the femoral component on different sawbones in a hip simulator. The position of the component was measured on postoperative radiographs. Variance for varus/valgus alignment and anteversion was higher for conventional implantation. Among the three surgeons, operation time, chosen implant size and anteversion were significantly different for conventional implantation but not for the navigated method. Using navigation, no difference was found for normal and abnormal anatomy. Values obtained with the navigation system were consistent with those measured on radiographs. Navigation appeared to be accurate and helped to reduce outliers. This was true for the three different surgeons and in varying anatomical situations.</p>","PeriodicalId":50644,"journal":{"name":"Computer Aided Surgery","volume":"17 2","pages":"77-85"},"PeriodicalIF":0.0000,"publicationDate":"2012-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/10929088.2011.652674","citationCount":"3","resultStr":"{\"title\":\"Accuracy of navigation in hip resurfacing with different surgeons and varying anatomy.\",\"authors\":\"Iris Schleicher,&nbsp;Matthias Haselbacher,&nbsp;Eckart Mayr,&nbsp;Peter M Kaiser,&nbsp;Florian W Lenze,&nbsp;Alexander Keiler,&nbsp;Michael Nogler\",\"doi\":\"10.3109/10929088.2011.652674\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The accuracy of a commercial imageless navigation system for hip resurfacing and its reproducibility among different surgeons and for varying femoral anatomy was tested by comparing conventional and navigated implantation of the femoral component on different sawbones in a hip simulator. The position of the component was measured on postoperative radiographs. Variance for varus/valgus alignment and anteversion was higher for conventional implantation. Among the three surgeons, operation time, chosen implant size and anteversion were significantly different for conventional implantation but not for the navigated method. Using navigation, no difference was found for normal and abnormal anatomy. Values obtained with the navigation system were consistent with those measured on radiographs. Navigation appeared to be accurate and helped to reduce outliers. This was true for the three different surgeons and in varying anatomical situations.</p>\",\"PeriodicalId\":50644,\"journal\":{\"name\":\"Computer Aided Surgery\",\"volume\":\"17 2\",\"pages\":\"77-85\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.3109/10929088.2011.652674\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Computer Aided Surgery\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3109/10929088.2011.652674\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Computer Aided Surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3109/10929088.2011.652674","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 3

摘要

通过在髋关节模拟器中比较传统和导航股骨假体植入不同锯骨的情况,测试了商用无图像导航系统用于髋关节表面置换术的准确性及其在不同外科医生和不同股骨解剖结构中的可重复性。在术后x线片上测量组件的位置。常规植入术中内翻/外翻对准和前倾的方差较高。三种术式在手术时间、选择种植体大小和前倾上,常规种植方式差异显著,导航种植方式差异不显著。使用导航,正常解剖与异常解剖无差异。导航系统获得的数值与x光片测量值一致。导航似乎是准确的,有助于减少异常值。这对三位不同的外科医生和不同的解剖情况都是正确的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Accuracy of navigation in hip resurfacing with different surgeons and varying anatomy.

The accuracy of a commercial imageless navigation system for hip resurfacing and its reproducibility among different surgeons and for varying femoral anatomy was tested by comparing conventional and navigated implantation of the femoral component on different sawbones in a hip simulator. The position of the component was measured on postoperative radiographs. Variance for varus/valgus alignment and anteversion was higher for conventional implantation. Among the three surgeons, operation time, chosen implant size and anteversion were significantly different for conventional implantation but not for the navigated method. Using navigation, no difference was found for normal and abnormal anatomy. Values obtained with the navigation system were consistent with those measured on radiographs. Navigation appeared to be accurate and helped to reduce outliers. This was true for the three different surgeons and in varying anatomical situations.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Computer Aided Surgery
Computer Aided Surgery 医学-外科
CiteScore
0.75
自引率
0.00%
发文量
0
审稿时长
>12 weeks
期刊介绍: The scope of Computer Aided Surgery encompasses all fields within surgery, as well as biomedical imaging and instrumentation, and digital technology employed as an adjunct to imaging in diagnosis, therapeutics, and surgery. Topics featured include frameless as well as conventional stereotaxic procedures, surgery guided by ultrasound, image guided focal irradiation, robotic surgery, and other therapeutic interventions that are performed with the use of digital imaging technology.
期刊最新文献
One-step reconstruction with a 3D-printed, biomechanically evaluated custom implant after complex pelvic tumor resection. Quantitative analysis of velopharyngeal movement using a stereoendoscope: accuracy and reliability of range images. Numerical simulation of blood flow and plaque progression in carotid-carotid bypass patient specific case. Towards the clinical integration of an image-guided navigation system for percutaneous liver tumor ablation using freehand 2D ultrasound images. A comparison of two surgical approaches in functional neurosurgery: individualized versus conventional stereotactic frames.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1