{"title":"以聚吡咯-聚乙烯磺酸膜固定胆碱氧化酶制备测定胆碱的安培型生物传感器。","authors":"Merve Özdemir, Fatma Arslan, Halit Arslan","doi":"10.3109/10731199.2011.646411","DOIUrl":null,"url":null,"abstract":"<p><p>In this paper, a novel amperometric choline biosensor with immobilization of choline oxidase on electrochemically polymerized polypyrrole-polyvinylsulphonate (PPy-PVS) film has been accomplished via the entrapment technique. The effects of pH and temperature were investigated and optimum parameters were found to be 9.0 and 60 °C, respectively. There are two linear parts in the region between 1.0 × 10 (-7) - 1.0 × 10 (-6)M (R(2) = 0.997) and 1.0 × 10 (-5) - 1.0 × 10 (-3) M (R(2) = 0.986). The storage stability and operation stability of the enzyme electrode were also studied.</p>","PeriodicalId":8413,"journal":{"name":"Artificial cells, blood substitutes, and immobilization biotechnology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2012-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/10731199.2011.646411","citationCount":"7","resultStr":"{\"title\":\"An amperometric biosensor for choline determination prepared from choline oxidase immobilized in polypyrrole-polyvinylsulfonate film.\",\"authors\":\"Merve Özdemir, Fatma Arslan, Halit Arslan\",\"doi\":\"10.3109/10731199.2011.646411\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>In this paper, a novel amperometric choline biosensor with immobilization of choline oxidase on electrochemically polymerized polypyrrole-polyvinylsulphonate (PPy-PVS) film has been accomplished via the entrapment technique. The effects of pH and temperature were investigated and optimum parameters were found to be 9.0 and 60 °C, respectively. There are two linear parts in the region between 1.0 × 10 (-7) - 1.0 × 10 (-6)M (R(2) = 0.997) and 1.0 × 10 (-5) - 1.0 × 10 (-3) M (R(2) = 0.986). The storage stability and operation stability of the enzyme electrode were also studied.</p>\",\"PeriodicalId\":8413,\"journal\":{\"name\":\"Artificial cells, blood substitutes, and immobilization biotechnology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.3109/10731199.2011.646411\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Artificial cells, blood substitutes, and immobilization biotechnology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3109/10731199.2011.646411\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2012/4/3 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Artificial cells, blood substitutes, and immobilization biotechnology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3109/10731199.2011.646411","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2012/4/3 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
An amperometric biosensor for choline determination prepared from choline oxidase immobilized in polypyrrole-polyvinylsulfonate film.
In this paper, a novel amperometric choline biosensor with immobilization of choline oxidase on electrochemically polymerized polypyrrole-polyvinylsulphonate (PPy-PVS) film has been accomplished via the entrapment technique. The effects of pH and temperature were investigated and optimum parameters were found to be 9.0 and 60 °C, respectively. There are two linear parts in the region between 1.0 × 10 (-7) - 1.0 × 10 (-6)M (R(2) = 0.997) and 1.0 × 10 (-5) - 1.0 × 10 (-3) M (R(2) = 0.986). The storage stability and operation stability of the enzyme electrode were also studied.