基于络合平衡方程的血清离子钙计算模型。

Analytical Chemistry Insights Pub Date : 2012-01-01 Epub Date: 2012-07-04 DOI:10.4137/ACI.S9681
Susumu Takano, Hiroshi Kaji, Fujio Hayashi, Kanae Higashiguchi, Sachie Joukei, Yoshiaki Kido, Juro Takahashi, Kayo Osawa
{"title":"基于络合平衡方程的血清离子钙计算模型。","authors":"Susumu Takano,&nbsp;Hiroshi Kaji,&nbsp;Fujio Hayashi,&nbsp;Kanae Higashiguchi,&nbsp;Sachie Joukei,&nbsp;Yoshiaki Kido,&nbsp;Juro Takahashi,&nbsp;Kayo Osawa","doi":"10.4137/ACI.S9681","DOIUrl":null,"url":null,"abstract":"<p><p>Measurement of ionized calcium is more important than measurement of total calcium in serum samples. In the present study, equations were derived from complexation and acid dissociation equilibrium equations, and were used to determine the concentration of ionized calcium from the observed serum concentrations of total calcium, albumin, total protein, and inorganic phosphate. The ionized calcium concentration was calculated in 67 serum samples from healthy subjects and 34 outpatients previously identified as having abnormal serum calcium levels. The correlation coefficient between our method (y) and the calcium-ion-selective electrode method (x) was 0.953 and the linear regression equation was y = 0.97x at pH 7.4 with a factor of α = 0.21, which was based on the differences between the concentrations of calcium phosphorus compounds obtained by the electrode method and by calculation. The developed calculation is as useful and accurate as the electrode method, and therefore extremely useful for clinical diagnoses.</p>","PeriodicalId":7781,"journal":{"name":"Analytical Chemistry Insights","volume":"7 ","pages":"23-30"},"PeriodicalIF":0.0000,"publicationDate":"2012-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.4137/ACI.S9681","citationCount":"12","resultStr":"{\"title\":\"A calculation model for serum ionized calcium based on an equilibrium equation for complexation.\",\"authors\":\"Susumu Takano,&nbsp;Hiroshi Kaji,&nbsp;Fujio Hayashi,&nbsp;Kanae Higashiguchi,&nbsp;Sachie Joukei,&nbsp;Yoshiaki Kido,&nbsp;Juro Takahashi,&nbsp;Kayo Osawa\",\"doi\":\"10.4137/ACI.S9681\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Measurement of ionized calcium is more important than measurement of total calcium in serum samples. In the present study, equations were derived from complexation and acid dissociation equilibrium equations, and were used to determine the concentration of ionized calcium from the observed serum concentrations of total calcium, albumin, total protein, and inorganic phosphate. The ionized calcium concentration was calculated in 67 serum samples from healthy subjects and 34 outpatients previously identified as having abnormal serum calcium levels. The correlation coefficient between our method (y) and the calcium-ion-selective electrode method (x) was 0.953 and the linear regression equation was y = 0.97x at pH 7.4 with a factor of α = 0.21, which was based on the differences between the concentrations of calcium phosphorus compounds obtained by the electrode method and by calculation. The developed calculation is as useful and accurate as the electrode method, and therefore extremely useful for clinical diagnoses.</p>\",\"PeriodicalId\":7781,\"journal\":{\"name\":\"Analytical Chemistry Insights\",\"volume\":\"7 \",\"pages\":\"23-30\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.4137/ACI.S9681\",\"citationCount\":\"12\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Analytical Chemistry Insights\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4137/ACI.S9681\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2012/7/4 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Chemistry Insights","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4137/ACI.S9681","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2012/7/4 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 12

摘要

血清样品中离子钙的测定比总钙的测定更重要。在本研究中,从络合和酸解离平衡方程推导出方程,并通过观察血清中总钙、白蛋白、总蛋白和无机磷酸盐的浓度来确定电离钙的浓度。计算了67个健康人的血清样本和34个先前确定为血清钙水平异常的门诊患者的游离钙浓度。根据电极法计算的钙磷化合物浓度与电极法计算的钙磷化合物浓度的差异,在pH 7.4条件下,本方法与钙离子选择电极法的相关系数(y)为0.953,线性回归方程为y = 0.97x,因子为α = 0.21。所开发的计算与电极法一样有用和准确,因此对临床诊断非常有用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A calculation model for serum ionized calcium based on an equilibrium equation for complexation.

Measurement of ionized calcium is more important than measurement of total calcium in serum samples. In the present study, equations were derived from complexation and acid dissociation equilibrium equations, and were used to determine the concentration of ionized calcium from the observed serum concentrations of total calcium, albumin, total protein, and inorganic phosphate. The ionized calcium concentration was calculated in 67 serum samples from healthy subjects and 34 outpatients previously identified as having abnormal serum calcium levels. The correlation coefficient between our method (y) and the calcium-ion-selective electrode method (x) was 0.953 and the linear regression equation was y = 0.97x at pH 7.4 with a factor of α = 0.21, which was based on the differences between the concentrations of calcium phosphorus compounds obtained by the electrode method and by calculation. The developed calculation is as useful and accurate as the electrode method, and therefore extremely useful for clinical diagnoses.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
An Accurate Assessment of Docosahexaenoic Acid in Laying Hen Serum for Regulatory Studies. In Vitro Studies of the Antimicrobial and Free-Radical Scavenging Potentials of Silver Nanoparticles Biosynthesized From the Extract of Desmostachya bipinnata. Analytical Methods for the Determination of Mineral Oil Saturated Hydrocarbons (MOSH) and Mineral Oil Aromatic Hydrocarbons (MOAH)-A Short Review. Chitosan Membrane Embedded With ZnO/CuO Nanocomposites for the Photodegradation of Fast Green Dye Under Artificial and Solar Irradiation. Ten Basic Rules of Antibody Validation.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1